Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 13 - 13
1 Jun 2015
Ramakrishna S Leslie D Vijayaraghavan J Clarke H
Full Access

Corail implants have shown to give good results in elective total hip replacements (THR) and in hemi-arthroplasties. Pre-operative planning to identify the correct size of the Corail implant is vital for good post-operative outcomes. An undersized implant can lead to subsidence. The aim of the study was to review the incidence of subsidence. Post-operative radiographs of trauma patients (n=39) and elective (n=45) patients who had Corail femoral implants were reviewed. The implant-to-canal (I:C) ratio were calculated at the given 50% and 70% levels of the Corail implant. Follow up radiographs were reviewed to identify subsidence. The average age of patients was 80.3 years (range 66–93 years) in hemi-arthroplasties and 61 years (range 18–88) in elective THRs. The implant to canal (I:C) ratio at the 50% and 70% levels in trauma patients were 0.77 (range 0.54 – 0.97) and 0.81 (range 0.59 – 0.94) respectively. In elective patients, the ratios at the 50% and 70% marks were 0.77 (range 0.57 – 0.98) and 0.81 (0.56 – 0.95). One case of subsidence was seen in a collarless implant and I:C ratios at 50% and 70% were 0.57 and 0.56. A larger study is required to determine the reliability of this novel ‘implant:canal’ ratio to predict incidence.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 581 - 581
1 Aug 2008
Arastu M Vijayaraghavan J Robinson J Chissell H Hull J Newman J
Full Access

Background: We have noted a concerning number of early failures (as defined by revision) for Preservation medial mobile-bearing uni-compartmental knee replacements (UKR’s) implanted in our hospital. This study retrospectively reviewed the postoperative radiographs to see if these were as a result of surgical technical failure.

Methods: Between 2003 and 2004, 43 medial mobile-bearing Preservation UKR’s were implanted into 39 patients. The average age of the patients at the time of the index procedure was 61.4 years (range, 46–85), (20 males). The immediate post-operative radiographs were reviewed by 2 independent orthopaedic consultants and a registrar, who were blinded to the patient outcomes, using the radiographic criteria used for the Oxford UKR. We however, particularly tried to identify any medio-lateral offset between femoral and tibial components due to the constrained nature of the prosthesis. A compound error score for all other technical errors was also calculated for each patient.

Results: Six (13.9%) of 43 knees were revised (5 for persistent pain, 1 for tibial component subsidence). Technical errors were few and no correlation was found between post-operative radiographic appearances and the subsequent need for revision. The mean compound error score (maximum value 18) was 4.5 (range, 2–9) in the revision cases and in the non revised cases 3.2 (range, 0–8).

Conclusions: We believe this study gives credence to the opinion that the DePuy Preservation mobile-bearing implant has design faults and is over-constrained leading to early failures in some cases.