Following the establishment of regional Major Trauma Networks in England in 2012, there were concerns that pressures regarding resource allocation in Major Trauma Centres (MTCs) may have a detrimental impact on the care of patients with hip fractures in these hospitals. This study aimed to compare outcomes in hip fracture care between MTCs and trauma units (TUs). National Hip Fracture Database data was extracted from 01/01/2015 to 31/12/2022 for all hospitals in England. Outcome measures included perioperative medical and physiotherapy assessments, time to surgery, consultant supervision in theatre, Best Practice Tariff (BPT) compliance, discharge to original residence, and mortality. Data was pooled and weighted for MTCs and remaining hospitals (TUs). A total of 487,089 patients with hip fractures were included from 167 hospitals (23 MTCs and 144 TUs). MTCs achieved marginally higher rates of orthogeriatrician assessment within 72 hours of admission (91.1% vs 90.4%, p<0.001) and mobilisation out of bed by first postoperative day (81.9% vs 79.7%, p<0.001). A lower proportion of patients underwent surgery by the day after admission in MTCs (65.2% vs 69.7%, p<0.001). However, there was significantly higher consultant surgeon and anaesthetist supervision rates during surgery in MTCs (71.8% vs 61.6%, p<0.001). There was poorer compliance with BPT criteria in MTCs (57.3% vs 60.4%, p<0.001), and proportionately fewer MTC patients were discharged to their original residence (63.5% vs 60.4%, p<0.001). There was no difference between MTCs and TUs in 30-day mortality (6.8% vs 6.8%, p=0.825). This study demonstrates that MTCs have greater difficulty in providing prompt surgery to hip fracture patients. However, their marginally superior perioperative care outcomes appear to compensate for this, as their mortality rates are similar to TUs. These findings suggest that the regionalisation of major trauma in England has not significantly compromised the overall care of hip fracture patients.
In a number of disciplines, positive correlations have been reported between volume and clinical outcome. This has helped drive the evolution of specialist centres to deal with complex or high risk medical conditions. Hip fractures are a common injury associated with high morbidity and mortality. To assess whether volume of hip fracture cases attended to by individual hospitals is associated with the quality of care provided and clinical outcomes.Background
Aim
Hip fracture is a common injury with a high associated mortality. Many recommendations regarding timing of operative intervention exist for patients with such injuries. The Best Practice Tariff was introduced in England and Wales in 2010, offering financial incentives for surgery undertaken within 36 hours of admission. The England and Wales National Institute for Health and Clinical Excellence (NICE) Guidance states that surgery should be performed on the day or day after admission. Due to lack of clear evidence, this recommendation is based on Humanitarian grounds. NICE have called for further research into the effect of surgical timing on mortality. We utilised data from the National Hip Fracture database prospectively collected between 2007 and 2015, comprising 413,063 hip fractures. Using 11 variables, both Cox and Logistic regression analysis was used to establish the effect on mortality of each 12 hour interval from admission to surgery. For each 12 hour time frame from admission to surgery a trend for improved 30 day survival was demonstrated the earlier the surgery was performed. However, this did not reach significance until beyond 48 hours (Hazard ratio of 1.12, 95% CI: 1.04–1.20). Surgery after 48 hours suffered significantly higher chance of mortality compared to surgery done within 12 hours. This is the largest analysis undertaken to date. Lowest mortality rates are found within the 0–12 hour window. After 48 hours there is a significant increased risk of mortality compared to the 0–12 hour time frame. As such, expeditious surgery within 48 hours can be justified both on humanitarian and survivorship grounds. Hip fracture surgery performed within 48 hours is associated with reduced mortality when compared to that beyond this time. This is in agreement with Blue Book recommendations and extends the currently recommended NICE and Best Practice Tariff targets of 36 hours.
The Medicines and Healthcare Products Regulatory Agency (MHRA) of the UK have published guidelines for annual follow up of patients with metal on metal hip replacements following widespread concern regarding metallosis We followed up 718 total hip replacements (594 stemmed hips and 124 resurfacing) with metal on metal bearing, implanted between April 1999 and August 2010 in dedicated clinics with clinical and radiological assessment along with assessment of serum metal ions. Survival was calculated using Kaplan Meier analysis.Introduction
Methods
The surgical treatment options for patients who have sustained an intra-capsular hip fracture can vary depending on a number of patient and fracture related factors. Currently most national guidelines support the use of cemented prostheses for patient undergoing hemi-arthroplasty surgery. Uncemented prostheses are commonly used for a variety of indications including those patients who have significant medical co-morbidities. To determine whether cemented hemi-arthroplasty is associated with a higher post operative mortality when compared to uncemented procedures. Data was extracted from the Scottish SMR01 database from 01/04/1997 from all patients who were admitted to hospital after sustaining a hip fracture. We investigated mortality at day 1, 2, 4, 7, 30, 120 and 1 year from surgery vs. that on day 0. In order to control for the effects of confounding variables between patients cohorts, 12 case-mix variable were used to construct a multivariable logistic regression analysis model to determine the independent effect of prosthesis fixation method. There were 64,979 patients were included in the study. Mortality for osteosynthesis of extra-capsular fractures was consistently lower when compared to that for surgical procedures for intra-capsular fractures. At day 0, uncemented hemi-arthroplasty operations had a lower associated mortality (p<0.001) when compared to cemented implant designs. Unadjusted figures showed an increased mortality equal to 1 extra death per 424 procedures. By day 1 this had become 1 extra death per 338 procedures. By day 7 cumulative mortality was less for cemented than for uncemented procedures though this did not reach significance until day 120. When compared to uncemented fixation techniques, cemented hemiarthroplasty is associated with a higher mortality in the immediate postoperative period. However, by day 120 and beyond the trend is reversed.
The surgical treatment options for patients who have sustained an intra-capsular hip fracture can vary depending on a number of patient and fracture related factors. Currently most national guidelines support the use of cemented prostheses for patient undergoing hemiarthroplasty surgery. Uncemented prostheses are commonly used for a variety of indications including those patients who have significant medical co-morbidities. To determine whether cemented hemiarthroplasty is associated with a higher post operative mortality when compared to uncemented procedures. Data were extracted from the Scottish SMR01 database from 01/04/1997 from all patients who were admitted to hospital after sustaining a hip fracture. We investigated mortality at day 1,2,4,7,30, 120 and 1 year from surgery vs. that on day 0. In order to control for the effects of confounding variables between patients cohorts, 12 case-mix variable were used to construct a multivariable logistic regression analysis model to determine the independent effect of prosthesis design. There were 52283 patients included in the study. Mortality for osteosynthesis of extra-capsular fractures was consistently lower when compared to that for surgical procedures for intra-capsular fractures. At day 0, uncemented hemiarthroplasty had a lower associated mortality (p<0.001) when compared to cemented implant designs. However, this increased mortality was equal to 1 extra death per 2000 procedures. From day 1 onward mortality for cemented procedures was equal to or lower than that of uncemented. By day 4, cumulative mortality was less for cemented than for uncemented procedures. Complication and re-operation rate was significantly higher in the uncemented cohort. The use of uncemented hemiarthroplasty for the treatment of intra-capsular hip fractures cannot be justified in terms of early/late post-operative mortality.
Serum lactate has been shown to be an indicator of adverse clinical outcomes in patients admitted secondary to general trauma or sepsis. We retrospectively investigated whether admission serum venous lactate can predict in-hospital mortality in patients with hip fractures. Over a 38-month period the admission venous lactate of 807 patients with hip fractures was collated. Mean age was 82 years. The overall in-hospital mortality for this cohort was 9.4%. Mortality was not influenced by the fracture pattern or the type of surgery - be it internal fixation or arthroplasty (p = 0.7). A critical threshold of 3 mmol/L with respect to the influence of venous lactate level on mortality was identified. Mortality rate in those with a lactate level of less than 3 mmol/L was 8.6% and 14.2% for those whose level was 3 mmol/L or greater. A 1 mmol/L increase in venous lactate was associated with a 1.2 (1.02–1.41) increased risk of in-hospital mortality. Patients with a venous lactate of 3 mmol/L or higher had twice the odds of death in hospital compared to matched individuals. There was no statistically significant difference in ASA distribution between those with a lactate of less than or greater than 3 mmol/L.Background and Purpose
Method and Results
Cauda equina syndrome (CES) is a physical process. There is compression of the cauda equina resulting in arrest of the electrochemical signal from the central nervous system. Previous studies have demonstrated that anthropomorphic features influence nerve conduction properties. We therefore sought to if there was an association between biophysical parameters and CES.Background
Aim
Large studies have reported high dislocation rates (7 to 24%) following revision total hip arthroplasty (THA), particularly when the revision is undertaken in the presence of pre-existing instability. We retrospectively reviewed the clinical and radiographic outcome of 155 consecutive revision THA's that had been performed using an unconstrained dual-mobility acetabular implant. It features a mobile polyethylene liner articulating with both the prosthesis head and a metal acetabular cup, such that the liner acts as the femoral head in extreme positions. It can be implanted in either a press fit or cemented manner. Mean follow-up was 40 months (18–66) and average age 77 (42–89). Uncemented (n=122) and cemented (n=33) implants with a reinforcing cage, were used. Indications were aseptic loosening (n=113), recurrent instability (n=29), periprosthetic fracture (n=11) and sepsis (n=2). Three of the 155 cases (1.9%) dislocated within 6 weeks of surgery and were successfully managed with closed reduction. The 3 dislocations occurred in the groups revised for recurrent dislocation and periprosthetic fracture. There were no cases of recurrent dislocation and no revisions for implant failure. Despite a pantheon of options available, post-operative dislocation remains a challenge especially in patients with risk factors for instability. The use of large diameter heads is proven to improve stability but there are concerns regarding wear rates, metal toxicity and recurrent dislocation in the presence of abductor dysfunction. With constrained liners there are concerns regarding device failure and aseptic loosening due to implant overload. Our dislocation rates of 1.9% and survivorship to date compare favourably with alternative techniques and are also in line with studies from France using implants of a similar design. In our hands, where there are risk factors for dislocation, the use of a dual-mobility implant has been very effective at both restoring and maintaining stability in patients undergoing revision THA.