Antigranulocyte scintigraphy with the use of monoclonal antibodies or antibody fragments (leukoscan) is a promising diagnostic tool that has been used widely during the recent years for the establishment of prosthesis infection after total hip or knee arthroplasty. In the present study we report the Ioannina University Hospital experience in the diagnostic efficacy of leukoscan for the diagnosis of prosthesis infection in patients with total hip or knee arthroplasty. We considered all patients with suspected total hip or knee arthroplasty infection that had undergone a leukoscan examination for the diagnosis of this infection in our department during the year 2004. All patients underwent a 3-phase bone scan and a subsequent leukoscan. For the whole group of patients the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were calculated by comparison of the results of three-phase bone scan or leukoscan with the results obtained from cultures of synovial fluid obtained from articular puncture or cultures of intraoperative sampling from those patients that had undergone a revision surgery. A total of 19 patients with total joint arthroplasty (12 THA and 7 TKA) and suspected prosthesis infection were included in the study. The mean age of patients was 67 years. Twelve patients had verification of prosthesis infection in cultures. The overall sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the three-phase bone scan were 54%, 83%, 88%, 45% and 63% respectively. On the contrary, the overall sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for leukoscan were 75%, 86%, 90%, 66% and 79%, respectively. Antigranulocyte scintigraphy with the use of monoclonal antibody fragment sulesomab (leukoscan) had good but not perfect diagnostic performance for the diagnosis of prosthesis infection in patients with total hip or knee arthroplasty.
Total hip arthroplasty (THA) in neglected congenital dislocation of the hip (CDH) constitutes a challenging procedure, with surgical difficulties and complications. The purpose of this study was to analyse the complications of THAs in CDH. Between June 1983 and September 2002, 418 THAs-were performed in 356 patients with CDH, with a mean follow-up 108 (7–237)months. The mean age at surgery was 53.3 (24–79) years with 325 females and31 males. 83 patients had CDH in high position. 307 arthroplasties were cementless, 39 cemented and 72 hybrids. 40 stems were custom made. The cup always was positioned at the true acetabulum. 24 shortening osteotomies of the femur, 8 corrective supracondylar and 6 trochanteric osteotomies were performed. Preoperatively the average Merle d’Aubigne-Postel hip score was 1.1 for pain, 4.8 for range of motion and 3.1 for walking ability. Postoperatively the average hip score was 5.2, 4.7 and 5.3 respectively. The average length discrepancy was 8 cm (3–12) preoperatively and 1.5 cm remained in 8 patients. Complications included 7 intraoperative fractures of the femur, 12 dislocations, 4 peroneal nerve palsies that recovered, 25heterotopic ossifications, 7 deep vein thromboses, 3 pulmonary embolisms, early mechanical loosening in 4 cemented and 10 cementless cups and 3infections. Complications were diminished dramatically last years due to improved surgical technique, new available implants and preoperative evaluation of the hip with CT and CAD-CAM-CAE study that allowed better surgical planning with trial stem implantation from a series of stem designs and custom made femoral components manufacturing
We present our experience from use of acetabular reinforcement rings in revision total hip arthroplasty when bone defects are present. From 1987 to 2000, acetabular reinforcement rings were utilized in 59 revisions, in 52 patients with a mean age of 60 years (31–81). In 48 hips, Ganz rings were used and in 11 hips, Burch-Sch-neider rings. For the existing defects of the acetabulum, morsellized bone allograft was used. The patients were evaluated clinically with the modified Merle d’ Aubigne-Postel scale and radiologically with the criteria of Gill-Sledge-Muller. Acetabular reconstruction was successful in 51 of 59 hips (86.5%) after a mean follow-up period of 7 years (2–15). One of the 11 Burch-Schneider rings failed (9.1%) and 7 of the 48 Ganz, raising the failure rate of this ring up to 14.6%. Complications included dislocation in 5 cases, deep vein thrombosis in 2, superficial infection in 1 and pubis rami fracture in 2 cases. Reinforcement rings in our opinion could be of valuable help in reconstruction of the bone deficient acetabulum. Although in this study, it is not possible for these two rings to be directly compared, Burch-Schneider one appears to have a more clear role and lower failure rate. However, in order to evaluate in a more reliable way the true fate of the acetabular reinforcement rings, especially in the presence of the limited role of biological fixation, longer follow-up time is needed.
This study of surgically treated distal tibia fractures was undertaken to compare the internal fixation with the two external fixation methods. There were 40 patients with 41 pilon fractures. The mean age was 51.2 years (18–76). 17 of the 40 patients-14 from vehicular accident, 3 from fall – were treated with an ankle-spanning half-pin external fixator (11C, 6B, 11 Weber B- 5 C, 1IIIa, 5I, 6II). 11 patients-10 from vehicular accident, 1 from fall- were treated with a single-ring hybrid ankle-spanning external fixator (9C, 2 B, 6 Weber B-4 C, 5I, 2II). 13 patients-10 from vehicular accident and 1 from fall- were treated with an epiunion plate (1A, 8B, 4C, 5I, 3II, 10 Weber B- 1C). The mean follow-up was 4.2years (1–8). Fracture union was defined as having three cortices bridging on the plain radiographs for a patient who was able to bear full weight. Non union was defined as a fracture that did not heal within a year. Fracture union was achieved for 36 of the 41 fractures. Three patients with external fixator, one with hybrid and one with plate had septic pseudarthrosis. Fractures in the external fixator and hybrid groups had a tendency to lose the reduction. Four patients with external fixator had delayed union and have lost range of motion in the ankle. Five patients in the external fixator group are candidates for ankle arthrodesis due to arthritis. The ORIF and hybrid fixator were equally efficacious in achieving bony union and not to lose range of motion in the ankle. Fractures in the external fixator with the ankle – spanning had higher rate of delayed union and loss of motion in ankle. The choice of the external fixator is dependent on the surgeon and the type of the fracture. However the patient must be followed up for the stability of the system.
This study describes the clinical features and treatment of the 53 patients with primary tumors of the hand. A review of primary tumors of the small bones of the hand during a 9 year period (1991–2001) was done. There were 14 enchondromas, 1 malignant fibrous histiocytoma, 15 ganglions, 5 haemangiomas, 1 haemangioma of median nerve, 4 giant cell tumors of tendon sheath, 4 osteoid osteomas, 1 lymphangioma, 1 exostosis, 1 dermatofibrosarcoma, 1 neurilemoma, 2 neurinomas, 1 glomus tumor, 1 benign fibrous histiocytomas and 1 papillary endothelial hyperplasia. There were 34 males and 19 females with an average age 37.7 years. The mean follow-up was 6y (1–8y). There were 33 lesions in the fingers, 3 in the metacarpals, 13 in the carpus and 4 in the palm. Swelling and localized tenderness were the most common presenting complaints. One patient died of metastatic disease. 3 patients were seen initially with locally reccurent lesion. All the patients were treated surgically. The material was analyzed in terms of diagnosis, localization, surgical management and post-operative complications. Primary tumors of the hand are rare. The cases in these series are similar to that of other reports. As in other musculoskeletal neoplasms, a treatment plan must be formulated based on the location, size and biologic behaviour of the lesion.
We present the results of custom made cementless implants for treatment of osteoarthritis due to congenital disease of hip and osteonecrosis due to other diseases, where the normal anatomy was severely modified and it was impossible to insert the smallest available implant. There were 43 patients with 52 hips, 6 males – 46 females. The mean age was 48years (22–61). The mean follow-up was 24 months (1–48). There were 32 patients with low dislocation, 14 with high dislocation, 1 with infantile septic arthritis, 1 with Hodgkin disease, 1 with dysplasia, 1 with ankylosing spondylitis, 1 with congenital varus hip and 1 with Perthes disease. Our protocol was consisted of plain radiographs and CT of the acetabulum, femur, knee condylars and foot in order to be evaluated the bone stock of acetabulum and the femur anteversion. All the patients were evaluated – according to the Merle D’ Aubigne score – two, three and every six months after the operation. There was one complication with a proximal femur fracture in a high dislocated hip during the operation and two complications postoperatively. Both of them were high dislocated hips, and the one had paresis of sciatic nerve, that it recovered. The other had septic loosening and was undertaken revision in two stages. All the patients improved in pain, in walking ability and in range of motion. The impossibility of using the smallest available implant due to the high deformity and the young age led us to use custom made implant. Although a long follow-up is required for these procedures the first results are very encouraging according to the recovery of the patients which were related to the restoration of hip biomechanics provided by the three dimensional neck orientation.
The most common management of open injuries of the extensor tendons in Zones III to V (PIP to MP joint) is tendon suturation and digit immobilisation in extension for 4 to 6 weeks. Dynamic splinting and early mobilisation has been already successfully tested in the treatment of extensor tendons injuries in Zones VI to VII. In the current study we performed a protocol, including strong suture technique of the lacerated extensor tendon in Zone III to IV in addition with early mobilisation. From 1999 until 2002, 23 lacerated extensor tendons (Zones III – V) in 22 patients were managed at the Orthopaedic Department of the Univercity of Ioannina. The mean age of the patients was 36 years old (14 – 70 years). The principle treatment has taken place at the emergency room and included suture of the lacerated central slip, using the Kessler-Tajima technique, plus continuous suture of the epitenon. Injuries of other structures (lateral bands, sagittal band, joint captule) were also managed by suturing. After a period of 5 days (Zone V) to 3 weeks (Zone III) of immobilisation in a static splint, injured digit mobilisation started using a dynamic extensor splint until the 5th week after injury. The mean follow up was 7 months (3–24 months). There have been no ruptures of the extensor mechanism nore permanent digit deformities. Minimal (until 30o) loss of MP flexion or DIP extension has been regarded in 5 patients. The grip strength has been affected in 4 patients, and the grip strength between the 1st and 2nd digit (“the key pinch strength”) has been affected in 12 patients, compared with the contralateral hand. No further operation for tenolysis has been necessary. Satisfactory results have been obtained, by early mobilisation using dynamic splinting, in the treatment of open injuries of extensor tendons in Zones III – IV under the following conditions: using strong suture technique, a co-operative patient and weekly examination of the patient. Using a dynamic splint only for the injured digit is better accepted by the patient.
Total hip arthroplasty (THA) in neglected congenital dislocation of the hip (CDH) constitutes a challenging procedure, with surgical difficulties and complications. The purpose of this study was to analyse the complications of THAs in CDH. Between June 1983 and September 2002, 418 THAs were performed in 356 patients with CDH, with a mean follow-up 108 (7–237) months. The mean age at surgery was 53.3 (24–79) years with 325 females and 31 males. 83 patients had CDH in high position. 307 arthroplasties were cementless, 39 cemented and 72 hybrids. 40 stems were custom made. The cup always was positioned at the true acetabulum. 24 shortening osteotomies of the femur, 8 corrective supracondylar and 6 trochanteric osteotomies were performed. Preoperatively the average Merle d’Aubigne-Postel hip score was 1.1 for pain, 4.8 for range of motion and 3.1 for walking ability. Postoperatively the average hip score was 5.2, 4.7 and 5.3 respectively. The average length discrepancy was 8 cm (3–12) preoperatively and 1.5 cm remained in 8 patients. Complications included 7 intraoperative fractures of the femur, 12 dislocations, 4 peroneal nerve palsies that recovered, 25 heterotopic ossifications, 7 deep vein thromboses, 3 pulmonary embolisms, early mechanical loosening in 4 cemented and 10 cementless cups and 3 infections. Complications were diminished dramatically last years due to improved surgical technique, new available implants and preoperative evaluation of the hip with CT and CAD-CAM-CAE study that allowed better surgical planning with trial stem implantation from a series of stem designs and custom made femoral components manufacturing.
INTRODUCTION: The treatment of “congenital hip disease” by total hip arthroplasty is now well established, but the indications for this type of surgery, the preoperative planning, the selection of the stem and the technique to be followed are still open to debate. AIM OF THE STUDY: The purpose of this study is to analyse the long-term follow up after use of the cementless-system (CLS) femoral component designed by Spotorno in dysplastic or congenitally dislocated hips. MATERIAL AND METHODS: Our study includes 70 hips in 59 patients, 49 females and 10 males, 36 left hips and 34 right hips that treated with total hip arthroplasty from 1987 to 2000. The mean age of the patients was 48.5 years (range 34–74 years). Forty-one hips were congenitally dislocated and twenty-nine were severe dysplastic. Preoperative planning with CT and CAD-CAE system were used for selection of the stem. 11 patients had bilateral total hip arthroplasties with Spotorno CLS stem. RESULTS: The mean follow up was 8.1 years (range 2–14 years). No patients were lost during the follow-up period. Patients were evaluated clinically with Merle d’ Aubigne and Postel hip score. There was a significant postoperative clinical improvement of the mean pain score by 3.7 points, of walking ability by 2.2 points and of motion by 2,6 points. Thigh pain was not reported. There were no deep infections or mechanical loosenings that required revision of the femoral component. CONCLUSIONS: Although, the femoral component Spotorno CLS is used to every kind of hip diseases, had excellent long-term clinical results in adults, with dysplasia or congenital hip dislocation. Spotorno CLS uncemented femoral component represents an attractive option for adults with “congenital hip disease”.