In the UK, the NHS generates an estimated 25 megatonnes of carbon dioxide equivalents (4% to 5% of the nation’s total carbon emissions) and produces over 500,000 tonnes of waste annually. There is limited evidence demonstrating the principles of sustainability and its benefits within orthopaedic surgery. The primary aim of this study was to analyze the environmental impact of orthopaedic surgery and the environmentally sustainable initiatives undertaken to address this. The secondary aim of this study was to describe the barriers to making sustainable changes within orthopaedic surgery. A literature search was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines through EMBASE, Medline, and PubMed libraries using two domains of terms: “orthopaedic surgery” and “environmental sustainability”.Aims
Methods
The aims of this study were to assess mapping models to predict the three-level version of EuroQoL five-dimension utility index (EQ-5D-3L) from the Oxford Knee Score (OKS) and validate these before and after total knee arthroplasty (TKA). A retrospective cohort of 5,857 patients was used to create the prediction models, and a second cohort of 721 patients from a different centre was used to validate the models, all of whom underwent TKA. Patient characteristics, BMI, OKS, and EQ-5D-3L were collected preoperatively and one year postoperatively. Generalized linear regression was used to formulate the prediction models.Aims
Methods
This is a prospective study looking at 116 consecutive total hip replacements in 110 patients using the C-Stem total hip replacement system (Depuy International, Leeds, UK) between March 2000 and October 2002. This is the first documented study of results of the C-Stem outside Wrightington Hospital where it was developed. There were 69 females and 41 male patients. Average age was 66 years (Range 32 – 89 years). 64 patients had a right hip replacement, 52 patients had a left hip replacement and 6 were bilateral. The duration of follow up was from 24 to 55 months, with an average of 38.75 months. All patients had a cemented C-stem via a posterior approach. 107 with a metal head and 9 with a ceramic head. Cemented, all polyethylene cups were used. 82 hips had an Opera cup inserted and 34 had an Ogee cup inserted. Palacos R with Gentamicin was used for the cement. 103 femoral stems were neutral.12 stems were in varus (5–10 degrees) and 1 stem was in valgus (5–10degrees). No stems were greater than 10 degrees in either direction. There were no lucencies in any of the zones described by Gruen. The average amount of subsidence of the stem was 0.86mm (range 0–4mm). The average cup angle was 44.29 degrees (SD = +/− 4.85). 8 acetabular components had a 0.5mm lucent area in zone 1 and 2 acetabular components had 1mm lucent area in zone 1. All of these lucencies were present on the immediate postoperative x-ray and none were progressive. There were no lucencies in the other zones. There have been no incidences of deep infection, fatal P.E, dislocation or revision. We conclude that the C-Stem has produced excellent results in the short term in keeping with the criteria of the NICE guidelines.
Bladder catheterisation following joint arthroplasty is not uncommon but delaying catheterisation in the postoperative period until the patient is symptomatic can produce an atonic bladder due to the distension. This can prolong catheterisation and increase the risk of urinary tract infection. We prospectively determined if we could identify patients needing pre-operative catheterisation.
Nocturia was significantly more common in-patients requiring catheterisation (Kruskal Wallis P=0.04) and its combination with pre-operative symptoms of frequency, retention or incontinence increased the significance further to P=0.001. Patient age of greater then 66 years had a 76.6% predictive value for the subsequent need of catheterisation. This further increased to 91.5% when combined with a previous history of either catheterisation or nocturia. The type of anaesthesia or the post-operative analgesia did not significantly influence catheterisation frequency.