Our unit historically performed total hip replacement (THR) through either posterior or anterolateral approaches. In November 2020 a group of 5 consultants transitioned to utilising the Direct Anterior Approach (DAA). Appropriate training was undertaken and cases were performed as dual consultant procedures with intraoperative radiography or robotic assistance. Outcomes were collated prospectively. These included basic demographics, intraoperative details, complication rates and Oxford Hip Scores. A total of 48 patients underwent DAA THR over 1 year. Mean age was 67 and ASA 2. Over this time period 140 posterior approach and 137 anterolateral approach THR's were performed with available data. Propensity score matching was performed on a 1:1 basis using BMI, Age, Sex and ASA as covariates to generate a matched cohort group of conventional approach THR (n=37) Length of stay was significantly reduced at 1.95 days (p<0.001) with DAA compared to Anterolateral and Posterior approach. There was no significant difference with length of surgery, blood loss, Infection, dislocation and periprosthetic fracture rate. There was no significant difference in Oxford Hip Score between any approach at 3 months or 1 year. The transition to this approach has not made a negative impact despite its associated steep learning curve, and has improved efficiency in elective surgery. From our experience we would suggest those changing to this approach receive appropriate training in a high-volume centre, and perform cases as dual consultant procedures.
The primary aim was to assess the rate of patient deferral of elective orthopaedic surgery and whether this changed with time during the coronavirus disease 2019 (COVID-19) pandemic. The secondary aim was to explore the reasons why patients wanted to defer surgery and what measures/circumstances would enable them to go forward with surgery. Patients were randomly selected from elective orthopaedic waiting lists at three centres in the UK in April, June, August, and September 2020 and were contacted by telephone. Patients were asked whether they wanted to proceed or defer surgery. Patients who wished to defer were asked seven questions relating to potential barriers to proceeding with surgery and were asked whether there were measures/circumstances that would allow them to go forward with surgery.Aims
Methods
The pain of arthritic disorders occurs in a social and environmental context. Thus, the pain of arthritis not only can affect the patient, but also the spouse. Numerous investigations have shown that the spouses of individuals with persistent pain report lower levels of marital satisfaction, higher rates of depression and lower quality of life. For the vast majority of patients with osteoarthritis, total hip (THA) or total knee (TKA) arthroplasty results in a significant reduction in pain, emotional distress, disability and a significant improvement in their quality of life and function. Little is currently known about how these recovery-related changes impact on the spouse or the marital relationship. Patients and their spouses were recruited within one-year following the arthroplasty surgery. Couples participated in a semi-structured interview and were each asked to recall their level of pain on a numerical rating scale from 1 to 10 before and after recovering from surgery, and provide a numerical rating score (10 points) for a set of seven questions pertaining to their level of disability in seven different activities of daily living. In addition, the spouses were asked to list in order of importance the ways in which the surgery of their spouse affected their overall quality of life. In total, 33 couples (66 respondents) answered the survey questionnaire. There were 17 male patients, 16 female patients who underwent 29 THAs and 4 TKAs. With regard to pain, the spouses estimated their partner's pain, both preoperatively and at the time of the survey, to be at a significantly higher level than the patient's perception (p=0.05). The spouses perceived a greater improvement in family/home responsibilities, recreation and social activities, and in their occupation than that noted by the partner. After the arthroplasty, the spouses indicated that their lives had improved with respect to doing more activities/leisure (70%), because there partner had less suffering (61%), they had more independence/less caregiving (54%), it improved their marital relationship (54%), they had a better social/family life (27%) and they were able to travel (27%). In addition to the patient, THA and TKA result in a significant improvement in quality of life and marital functioning of the spouse. This should not continue to be unrecognized as a significant benefit of the procedure.
Lower back pain is a leading cause of disability and a common condition seen by osteopaths. Evidence and advice for the safest lifting posture vary, as do healthcare practitioners' attitudes towards back pain. The aim of this study was to understand osteopaths' beliefs about safe lifting postures, their attitudes towards back pain, and to compare these findings with published data from physiotherapists and manual handling advisors. A cross-sectional electronic survey was used to invite a sample of UK osteopaths to select images that best represent their perception of safe lifting posture (straight or rounded back), and to complete the Back Pain Attitudes Questionnaire (Back-PAQ, Appendix 1). Data was analysed to assess lifting posture selection and relationship to back pain attitudes. 46 (85.2%) out of 54 osteopaths selected straight back posture as safest, these participants had significantly more negative attitudes to back pain injury (i.e. higher Back-PAQ scores), than the 8 osteopaths who selected a rounded back posture (p = 0.007). Data from 266 physiotherapists and 132 manual handling advisors revealed an overall agreement about straight back lifting posture, however revealed differences in Back-PAQ attitude between the professions.Purpose and background
Methods and results
Dislocation is one of the most common complications after revision THA using the posterolateral approach. Although the cause of dislocation after revision THA is multifactorial, the historically high dislocation rates have been shown to be significantly reduced by closing the posterior capsule and by the use of large diameter (36 and 40 mm) femoral heads. The relative importance of each of these strategies on the rate of dislocation remains unknown. We undertook a study to determine if increasing femoral head diameter, in addition to posterior capsule closure would influence the dislocation rate following revision THA. We retrospectively reviewed 144 patients who underwent a revision THA. We included all patients who underwent revision THA with closure of the posterior capsule and who had at least a 2-year minimum follow-up. We excluded patients undergoing a revision THA for dislocation or multistage revision for infection since these patients would likely have deficient posterior tissues. Forty-eight patients had a 28 mm femoral head, 47 had a 32 mm head and 49 patients had a 36 mm femoral head. At a minimum follow-up of 2 years, there were 3 dislocations. There were no dislocations in the 28 mm group (0%), 2 in the 32 mm group (4%) and 1 in the 36 mm group (2%). All patients were successfully treated with a closed reduction. No patients had recurrent dislocation. Head size alone was not found to significantly decrease the risk of dislocation (28mm vs 32mm p=0.12; 28mm vs 36mm p=0.27; 32mm vs 36mm p=0.40). Both large diameter heads and careful attention to surgical technique with posterior capsule closure can decrease the historically high dislocation rate after revision THA when utilizing the posterolateral approach. The additional use of a large diameter head did not have a significant impact on the already low dislocation rate. Capsular closure outweighs the effect of femoral head diameter in preventing dislocation following revision THA through a posterolateral approach.
Ideal treatment of displaced femoral neck fragility fractures in the previously ambulatory patient remains controversial. Treating these patients with total hip arthroplasty has improved patient reported outcomes and reduced rates of revision surgery compared to those treated with hemiarthroplasty. However, possible increased risk of dislocation remains a concern with total hip arthroplasty. The anterolateral and direct anterior approaches to total hip replacement have been applied in the femoral neck fracture population to minimize dislocation rates. However, the anterolateral approach has been associated with abductor injury and increased rates of heterotopic ossification while the anterior approach has been associated with peri-prosthetic femur fracture, lateral femoral cutaneous nerve injury, and wound complications. The Supercapsular Percutaneously Assisted (SuperPATH) approach was developed to minimize disruption of the capsule and short-external rotators in an effort to reduce the risk of dislocation and assist in quicker recovery in the elective hip arthroplasty setting. To achieve this, the SuperPATH technique allows the femur to be prepared in situ and the acetabulum to be reamed percutaneously once the femoral head is removed. This study investigates the post-operative time to ambulation, length of stay, discharge destination, and early dislocation rate of previously ambulatory patients with a displaced femoral neck fragility fracture that were treated with a total hip arthroplasty via the SuperPATH technique. A retrospective chart review was performed of previously ambulatory patients consecutively treated for a displaced femoral neck fragility fracture with a total hip replacement using the SuperPATH technique. Thirty-five patients were included in the study and examined for demographic data, time to ambulation, length of stay, major and minor complications during their hospital stay. Phone interviews were conducted to check for dislocation events.BACKGROUND
METHODS
The need for post-operative manipulation under anesthesia (MUA) for stiffness after primary total knee arthroplasty is a frustrating complication that can lead to suboptimal outcomes if range-of-motion to a functional level is not regained. Implant morphology and kinematics, PCL imbalance, and soft-tissue balancing can all contribute to post-operative stiffness. Utilization of total knee arthroplasty components that replicate the native knee's medial ball and socket kinematics may lead to easier maintenance of flexion post-operatively compared to conventional components. To determine if a medial pivot total knee arthroplasty design can reduce the need for post-operative MUA after primary total knee arthroplasty.BACKGROUND
PURPOSE
The direct anterior approach to THR has become an increasingly popular minimally-invasive technique in an effort to minimize dislocation risk, facility early recovery, and diminish soft tissue injury. However, it has been associated with unique complications including intraoperative femur fracture, cutaneous nerve palsy, stem subsidence, and wound healing complications. These risk of these complications have been documented to be more likely in the surgeon's early experience with the approach. The minimally-invasive Supercapsular Percutaneous-Assisted (SuperPATH) technique was developed to minimize capsular and short-external rotator injury, minimize dislocation risk, and provide an easier transition from the standard posterior approach. Fifty (50) consecutive elective total hip replacements in 48 patients were performed using the SuperPATH technique. These also represented the first fifty elective THRs the surgeon performed in practice. Indications were primary or secondary osteoarthritis (92%), avascular necrosis (6%), and impending pathologic fracture (2%). Patients were evaluated retrospectively for dislocation, major, and minor complications.INTRODUCTION
METHODS
Orientation of the acetabular component in total hip arthroplasty has been shown to influence component wear, stability, and impingement. Freehand placement of the component can lead to widely variable radiographic outcomes. Accurate abduction, in particular, can be difficult in the lateral decubitus position due to limited ability to appreciate and control positional obliquity of the pelvis. A CT-based mechanical navigation device has been shown to decrease cup placement error. This is an independent report of a single-surgeon's radiographic results using the device to control cup abduction. Sixty-four (64) consecutive elective THRs in 58 patients were performed via a supercapsular percutaneously-assisted (SuperPATH) surgical approach. Intraoperatively, the acetabular components were aligned with the aid of the CT-based mechanical navigation device (HipXpert; Surgical Planning Associates, Medford, MA). The cup orientation was then further adjusted to ensure that the anterior rim of the acetabular component was not prominent to avoid psoas impingement. Postoperatively, radiographic abduction was measured on standing postoperative radiographs.Introduction
Patients and Methods
While clinically successful for decades, CR TKA is persistently compromised by inconsistent PCL function. Problems of mid-flexion instability, incomplete knee flexion, erratic kinematic behavior and posterior instability, not seen with PS devices, raise concerns about the consistency of the technique, and the devices used. Most TKA systems offer at least 2 different geometries of tibial inserts to address this clinical problem. We hypothesize these problems are a result of compromise of PCL anatomy. To avoid compromise to the PCL 3 steps are required: 1) The slope of tibial resection must be less than 5°; 2) the depth of tibial resection must be based off the insertion footprint of the PCL, not the deficiencies of the tibial articular surface; and 3) the tibial insert must be modified to allow intraoperative balancing of the PCL. The CR Slope ™ implants and technique (Exactech) (“Posterior Cruciate Referencing Technique (PCRT)”) reflect this philosophy and have allowed consistent surgical intervention without PCL release and without multiple inserts. We present data identifying, the footprint, and the instrument and technique modifications that allow for predictable identification of the depth and angle of resection. At 2 years post implantation in the first 100 patients implanted, the study group has demonstrated similar operative time, LOS and Oxford knee scores (OKS), while ROM averaged 5° greater, and time to achieved flexion was decreased.Introduction
Results
There are approximately 1.2 million patients using orthotics in the UK costing the NHS in excess of £100 million per annum. Despite this, there is little data available to determine efficacy and patient compliance. There have been a few reports on patient satisfaction, which indicate that between 13-50% of patients are dissatisfied with their orthotics. Our aim was to evaluate patient reported satisfaction with orthotics prescribed and to investigate the reasons behind patient dissatisfaction. Seventy consecutive patients receiving foot orthoses at the Royal National Orthopaedic Hospital were retrospectively asked to complete a questionnaire and to bring their shoes and orthotics to research clinic. The inside width of the shoes and corresponding width of the orthotic were measured. A semi-structured interview was carried out on 10 patients, including those that were satisfied or unsatisfied, using qualitative research methods to identify issues that are important to patients.Introduction
Methods
A posterior AFO that holds the foot in dorsiflexion. The amount of dorsiflexion could be adjusted. An anterior AFO that keeps the ankle and foot in plantigrade, with no adjustment to the amount of dorsiflexion.
We introduce a new technique called the “Posterior Cruciate Referencing Technique” (PCRT), a specific combination of surgical technique, devices and instrumentation. Careful anatomic preservation of the posterior cruciate ligament (PCL) based upon a specific reference point off the tibia allows for use of sloped tibial components to achieve consistent functional behavior of the PCL. We discuss the preclinical design and development leading to availability of this device, and subsequent early clinical experience with this approach. Posterior cruciate ligament (PCL) retention in total knee arthroplasty (CR-TKA) has been a feature of certain styles of TKA since the inception of predictable TKA in the early 1970s. It has been adapted and promoted as advantageous for a number of real and theoretical benefits. In reality, however, PCL retention has proven inconsistent when applied across a broad range of surgical environments. A number of adaptations in surgical technique, device modification and instrumentation have been developed to try to improve the predictability of the surgical intervention and subsequent postoperative performance. It is our belief that currently recommended surgical techniques can lead to inconsistencies in surgical judgment and consequently performance of CR devices because they inadvertently compromise the anatomy and hence functional performance of the PCL. A study by Shannon et al showed that, during CR-TKA, the PCL was either partially or completely removed as a result of the tibial cut in two out of three cases [1]. Unlike the long held and validated approach of ligament releases for fixed New Technique for Functional Posterior Cruciate Retention in TKA varus and valgus deformity that, along with alignment, allow successful long 45 term outcomes, ligament release of the PCL to balance the knee in flexion, whether by bone cuts or physical release, may compromise its overall function and explain kinematic differences in expected versus observed performance. Our hypothesis is that devices, surgical techniques and instruments designed around anatomical and functional preservation of the PCL would promote a reproducible surgical approach and consistent clinical performance of a CR-TKA. This manuscript provides the rationale for development of a new technique called the “Posterior Cruciate Referencing Technique” (PCRT), a combination of technique, instruments and devices specifically designed to preserve the PCL anatomy and take advantage of the functional performance of the PCL. We discuss the anatomical, radiographic, kinematic and mechanical testing approach that suggests that this is a safe and effective approach for primary CR-TKA.
This is the first study to determine if closure of the posterior capsule during revision total hip arthroplasty (THA) results in a reduction in the historically high dislocation rate. Seventy-nine consecutive patients undergoing revision THA with a posterolateral approach and closure of the posterior hip capsule were retrospectively reviewed. At a mean follow-up of fifty-seven months (range twenty-four to one hundred and twenty months), there were only two dislocations (2.5%). The historically high dislocation rates with the posterolateral approach in revision THA, can be significantly decreased with posterior capsular closure from approximately 15% to 2.5%. To determine if closure of the posterior capsule during revision total hip arthroplasty results in a reduction in the historically high dislocation rate. The dislocation rate after revision THA with a posterior approach can be minimized by repairing the posterior capsule and rotators. The historically high dislocation rates with the pos-terolateral approach in revision THA, can be significantly decreased with posterior capsular closure from approximately 15% to 2.5%. A retrospective study was carried out to review seventy-nine consecutive revision THAs. In all cases, the surgery was done by a single surgeon using the posterolateral approach. In every case, the posterior capsule was meticulously repaired at the end of the procedure. All patients had a minimum two- year follow-up and no patients were lost to follow up. At a mean follow-up of fifty-seven months (range twenty-four to one hundred and twenty months), there were only two dislocations (2.5%). Both dislocations occurred early postoperatively were anterior. One occurred in a high risk case- a proximal femoral replacement with a trochanteric osteotomy, high hip center and skirted head. The other was due to a technical error, with the cup being excessively anteverted. There were no late dislocations or subluxations. The dislocation rate after revision THA with a posterior approach can be minimized by balancing soft tissues, correct implant alignment and repairing the posterior capsule and rotators.
Introduction: The clinical effectiveness of spinal bracing for the conservative treatment of adolescent idiopathic scoliosis is still not fully understood. Cohort studies on clinical effectiveness fail to adequately measure and control for confounding variables including spine flexibility, curve type, magnitude and maturity, distribution of corrective forces and compliance. This paper presents intermediate findings from a longitudinal study to objectively measure brace wear patterns and compliance in users of custom fitted TLSOs in the UK. Braces are fitted with data logging devices to measure temperature and humidity at the skin/brace interface. Previously reported measures of compliance have been in adolescents wearing Boston Braces using questionnaires, strap tension, interface pressure and skin temperature. They have shown compliance reported by the user can significantly over estimate actual compliance. Methods and results: 20 patients are being studied over 18 months. TLSOs are fitted with data logging devices to measure temperature and humidity at the skin/brace interface. They are discrete sensors inserted into a pocket formed on the posterior of the brace. Measurements are recorded at 16 minute intervals and data downloaded every three to four months. Results clearly demonstrate compliance and daily wear routines. Temperature and humidity at the skin/brace interface during periods of wear are 35°C and >
80%RH respectively. Compliance ranges from 60–98%. Users who stick rigidly to their regime only remove their brace in the evening. Where poorer compliance is evident, the brace is worn sporadically during the day and evening, and worn full time at night. Conclusion: Measurement of temperature and humidity at the skin/brace interface clearly demonstrates compliance and daily wear routines. Compliance varies from 60–98%. Where poor compliance is an issue it is intended to re-interview these individuals and obtain more detailed information about the reasons why they failed to use the brace.