The use of tourniquet in lower limb orthopaedic surgery is well established, however, it does have associated risks and complications and its use has been previously questioned. The purpose of this study was to compare postoperative pain scores, analgesic requirements and time to discharge in patients undergoing tourniquet assisted and non-tourniquet assisted routine knee arthroscopy. A total of 40 patients were randomised to tourniquet assisted and non-tourniquet assisted groups. Arthroscopy was performed using a standardised local anaesthetic infiltration in the non-tourniquet assisted group. All patients completed a postoperative pain score. Findings demonstrated that the incidence and mean scores for postoperative pain were significantly lower in the non-tourniquet group. Additionally postoperative analgesic requirements of patients in the non-tourniquet group were also found to be significantly lower and time spent in recovery and on the ward postoperatively was also lower in the non-tourniquet group compared to the tourniquet group. On the basis of the results in our study we recommend abolishing the use of tourniquet in routine knee arthroscopies in the virgin knee.
We have piloted a new system of purely therapist led clinics and assessed this with an anonymous patient survey.
Demographics, operation type and epidural rate were all correlated with the need for catheterization. In all cases the residual volumes were recorded.
The average residual volume at catheterization was 936mls, with a maximum of 2200mls. All patients were managed with intermittent catheterisation, most, (63%) requiring only a single episode before spontaneously voiding.
We were therefore unable to predict which patients would require catheterisation. Questioning and bladder palpation was found to be unreliable when assessing overdistention. Our study demonstrated that patients undergoing spinal surgery using epidural analgesia should be closely monitored in order to prevent overdistention of the bladder and has led to a proactive regimen for spinal patients with epidural analgesia in our unit.
The indication for revision was aseptic loosening in 16 cases, and deep sepsis in 13 cases, (12 were done in 2 stages). Others included polyethylene wear in 4 knees, instability in 2, and 1 each of peri-prosthetic fracture, implant breakage and pain of undetermined origin. 3 revisions were performed for failed Link Lubinus patello-femoral replacement. Mean interval between staged procedures for sepsis was 2 months. Reconstruction was performed using the Kinemax Revision system with the use of augments and stems. The modular rotating hinge was used in 4 cases. Surgical exposure included additional lateral release in 7 cases, tibial tubercle osteotomy in 4 and quadriceps snip in one.
At latest review, 7 patients had died due to unrelated causes with a pain free functioning knee prosthesis. Of the remaining 31, 26 patients had none or minimal pain. 21 were independently mobile with a satisfactory range of motion.10 patients needed a walking stick.