Principles of bone preservation and restoration of biomechanical alignment should be followed during revision total hip arthroplasty (THA). Where possible, conservative femoral revision techniques and even reconstructive de-escalation involving using primary stems should be considered. This study aims to investigate the outcome of patients who have undergone conservative femoral revision THA in our Institution. We retrospectively identified patients from our Institution's revision arthroplasty database who had cemented, or un-cemented primary stems implanted during revision THA of a previous stemmed femoral implant. Our primary outcome measure was all-cause re-revision THA with a secondary outcome measure of improvement in Oxford hip score (OHS). Radiographic evidence of stem loosening and post-op complications were recorded. Between 02/12/2014 to 12/12/2019, there were 226 patients identified with a mean follow up of 2 years (1–5 years). The majority of cases were represented by Paprosky type 1 (63%) and type 2 (25%) femoral defects. There were 45 patients (20%) who underwent impaction bone grafting (IBG) and 43 patients (19%) who had a cement in cement (CinC) femoral revision and cemented primary stem in 137 (60%), 1 uncemented stem with no IBG or CinC revision. Kaplan Meier survival for all-cause re-revision THA was 93.7% (95% CI: 88.3 – 100) at 3 years. The reasons for re-revision included 4 periprosthetic fractures, 4 dislocations, 1 deep infection, 1 loosening of femoral component and 1 loosening of acetabular component. Pre- and post-operative OHS scores were available in 137 hips (60%) with a mean improvement of 13. Radiographic review revealed 7% of cases with evidence of loosening in 1 or more Gruen zones. Our early results support the use of conservative femoral revision THA techniques where appropriate, with low complication and re-revision rates. Revisions using primary femoral components, where appropriate, should be considered in surgical planning to avoid unnecessary reconstructive escalation.
There are conflicting reports about the efficacy of injection to the thumb carpometacarpal joint (CMCJ) for osteoarthritis (OA). The accuracy of joint injection without radiological control is unclear. We investigated the accuracy of blind injection and recorded their immediate and short term efficacy. We injected 25 consecutive patients between March 2010-January 2011. The CMCJ was palpated, manually distracted and a 23 gauze needle introduced blindly. Image intensifier was then used to visualize and redirect needle if necessary. Radio-opaque dye was injected to confirm intra-articular placement. We recorded patient demographics, number of attempts required for correct needle placement, pre and 10 minutes post-injection visual analogue scale (VAS) pain score, and Nelson Score (NS)before and six weeks after injection. NS is a validated thumb CMCJ specific patient administered questionnaire.Introduction
Materials/Methods
The current treatment options available for Trapezio-metacarpal arthritis are injection, splint and ultimately surgery. The injections are predominantly done by General practitioners and no data is available to specialist. To investigate accuracy of injection and efficacy of injection in terms of short and long term pain relief.Background
Aim