There is little data on the long-term outcome of rotating hinge total knee arthroplasty. We provide a clinical and radiographic assessment of survivorship of the Kinematic rotating hinge total knee arthroplasty (How-medica, Rutherford, NJ), in a series of 72 implants, performed by a single surgeon in one unit, between 1983 and 1997. Survival analysis using known all cause revision revealed a 92% five-year implant survival, but worst-case scenario was 31% at five years. In a subset of 27 patients we used the Nottingham Health Profile (NHP) to assess prospectively the changes in health-related quality of life following rotating hinge arthroplasty. In this salvage arthroplasty setting we demonstrate a significant improvement in two modalities of the NHP (pain and physical mobility).
Method: 66 revision procedures for failed uncemented porous coated anatomic (PCA) total knee replacement were performed in 60 patients. At review, four patients had died while two were lost to follow up, therefore 60 knees in 54 patients were included in this prospective study. The principal indications for primary revision were polyethylene wear and loosening of the tibial base plate. 14 patients had a well fixed femoral component and hence were retained while 46 patients had both the components revised. All patients were prospectively assessed prior to surgery, at three months, six months and yearly thereafter. Review comprised clinical and radiological assessment. The mean follow up was 8.4 yrs (7–12 yrs)
At 5 years, the pain score for the revision group deteriorated but remained better than the baseline level. This is in contrast to post primary TKR, where the improvement in pain score was maintained from 3 months onwards.