header advert
Results 1 - 8 of 8
Results per page:
Applied filters
Content I can access

General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 464 - 464
1 Dec 2013
Okada Y Endou H Fujiwara K Kagawa Y
Full Access

Background

The main factor of osteoarthritis (OA) of the hip in Japan is secondary due to developmental dislocation of the hip and hip dysplasia. For this reason, navigation is useful to treat complicated cases.

Purpose

We performed total hip arthroplasty (THA) for the secondary OA of the hip using paired point matching and fluoroscopic matching, and compared the accuracy between them.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 313 - 313
1 Dec 2013
Fujiwara K Endou H Okada Y Kagawa Y Ozaki T
Full Access

Objectives

The setting angle of the cup is important for achieving the stability and avoiding the dislocation after total hip arthroplasty (THA). It is difficult to set the cup at correct angle in minimally invasive THA by modified Watson-Jones approach. So we use CT-based navigation system. We evaluated the accuracy of with post-operative CT data.

Materials and Methods

We treated 30 hips in 30 patients (7 male and 23 females) by navigated THA. 26 osteoarthritis hips, 2 rheumatoid arthritis hips and 2 idiopathic osteonecrosis hips were performed THA with VectorVision Hip 3.5.2 navigation system (BrainLAB). Implants were AMS HA cups and PerFix stems (Kyocera Medical, Osaka). Appropriate angles and positions of cups were decided on the 3D model of hip joint before operation. According to the preoperative planning, we put the cups with navigation system and stems without navigation system. We measured the anteversion angle with post-operative CT data and 3-dimensional template software.


Introduction:

One of the complications occurring after total knee arthroplasty (TKA) is venous thromboembolism (VTE). The current screening techniques for VTE are venography, lower extremity vascular ultrasound, pulmonary scintigraphy, and contrast-enhanced computed tomography (CT). Although venography and lower extremity vascular ultrasound can detect deep venous thrombosis (DVT) in the lower extremities, pulmonary thrombosis poses a diagnostic problem. We performed contrast-enhanced CT screening for DVT and pulmonary embolism (PE) after TKA, and assessed the efficacy of the following prophylactics for VTE: fondaparinux, enoxaparin, and edoxaban.

Materials and Methods:

Subjects included 219 patients (260 knees) undergoing TKA at our hospital between April 2007 and November 2012. The 260 subject knees were divided as follows: group C, 31 cases in which DVT prophylactics were not used (April 2007 to October 2008); group F, 107 cases receiving fondaparinux 2.5 mg/day (July 2007 to October 2009); group ENO, 87 cases receiving enoxaparin 2000–4000 IU/day (November 2009 to October 2011); and group EDO, 35 cases receiving edoxaban 15–30 mg/day (November 2011 to November 2012). Contrast-enhanced CT images were obtained from the pulmonary apex to the foot for diagnosis of VTE. Groups were compared for incidence of symptomatic PE, asymptomatic PE, DVT-negative asymptomatic PE, DVT-positive asymptomatic PE, and DVT.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 291 - 291
1 Mar 2013
Okada Y Abe N Miyazawa S Furumatsu T Fujii M Ozaki T
Full Access

Introduction

In Japan, edoxaban has been used for the prevention of venous thromboembolism (VTE) after total knee arthroplasty (TKA) since June 2011. Edoxaban is an oral direct factor Xa inhibitor, expected to be more convenient for the postoperative treatment of TKA. Enoxaparin, a II and Xa inhibitor, was approved in Japan for the prevention of VTE in patients undergoing orthopedics surgery from 2008. In this study, the effect for the prevention of VTE after TKA was compared between these two drugs in Japanese patients.

Patients and Methods

We studied 42 Japanese patients who underwent TKA from May 2011 to April 2012. The operations were performed under general anesthesia, continuous femoral nerve block, an air tourniquet, and using cements for implant fixation. These patients were divided in two groups, use of 30 mg edoxaban once daily (ED group), and use of 1000 IU of enoxaparin twice daily (EN group). The initial dose was administered between 12 and 21 hours after surgery. We compared the incidence of VTE, bleeding complications, D dimer levels, and hemoglobin (Hb) loss. The screening of VTE was performed by enhanced CT scan screening from the chest to the foot on postoperative day 5 or 6 in all patients. The bleeding complication was divided into major bleeding and minor bleeding with Japanese guideline for the prevention of VTE. D dimer levels and Hb levels were preoperatively and postoperative day 1, 3, 5, 7, and 14. The loss of Hb was calculated from preoperative Hb level minus lowest postoperative Hb level.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 177 - 177
1 Mar 2013
Fujiwara K Endou H Okada Y Mitani S Ozaki T
Full Access

Objectives

The anteversion angle of the cup is important for achieving the stability and avoiding the dislocation after total hip arthroplasty (THA). We place the component considering with the change of inclination of pelvis with its posture change. We analyzed the perioperative pelvic inclination angles with posture change and the time course.

Materials and Methods

We treated 40 hips in 40 patients (9 males and 31 females) with cementless THA that were performed from January 2007 to December 2008 in our hospital. 30 osteoarthritis hips, 3 rheumatoid arthritis hips and 7 idiopathic osteonecrosis hips were included. All patients were performed THA with VectorVision Hip 2.5.1 navigation system (BrainLAB, Feldkirchen, Germany). We used AMS HA cups and PerFix stems (KYOCERA Medical co., Osaka, Japan). The mean age of surgery was 59 years old (35–79 years old). The pelvic inclination angles (PIA) were measured with anteroposterior radiographic image in accordance with the Doiguchi's method.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 208 - 208
1 Mar 2013
Kagawa Y Fujiwara K Endou H Okada Y Tetsunaga T Mitani S Ozaki T
Full Access

Purpose

CentPillar GB HA stem (stryker®) is developed as the stem fitting the Japanese femur, and now there is CentPillar TMZF HA stem (stryker®) as the improvement type of the stem by coating the PureFix HA with plasma spray. We observed the factors which influenced on the stem subsidence between the two-type stems.

Materials and Methods

We intended for 26 hips 23 patients that we performed total hip arthroplasty (THA) during the period between January 2005 and June 2009 and were able to follow up more than three years. 10 males 11 hips and 13 females 15 hips, the mean age at the time of surgery was 56.5 (range, 29–74) years old, and primary diseases were osteoarthritis (OA) in 17 hips, Idiopathic Osteonecrosis of Femoral Head (ION) in six hips, and rheumatoid arthritis (RA) in three hips. 16 hips were treated with the CentPillar GB HA stem (G group), and 10 hips were performed with the CentPillar TMZF HA stem (T group). The examination items are the stem size, the canal fill ratio of the stem (the top of lesser trochanter, the bottom of lesser trochanter, the distal portion of the stem) and the stem alignment (on anteroposterior radiograph and Lauenstein view).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 173 - 173
1 Mar 2013
Fujii M Abe N Furumatsu T Miyazawa S Okada Y Ozaki T
Full Access

Purpose

Computer navigation system has been reported as a useful tool to obtain the proper alignment of lower leg and precise implantation in TKA. This system alsoãζζhas shown the accurate gap balancing which was lead to implants longevity and optimal knee function. The aim of this study was determine that the postoperative acquired deep knee flexion would be influenced by intraoperative kinematics on navigated TKA even under anesthesia.

Materials & methods

Forty knees from 40 patients, who underwent primary TKA (P.F.C. sigma RPF, DePuy Orhopaedic International, Leed, UK) with computer-navigation system (Ci Knee, BrainLAB / DePuy Inc, Leeds, UK), were recruited in this study. These patients were classified into two groups according to the recorded value of maximum knee flexion at three month after surgery: 15 patients who obtained more than 130 degrees of flexion in Group A, and 25 patients less than 130 degrees in Group B. We retrospectively reviewed about intraoperative kinematics in each group, to obtain the clue for post operative deep-flexion. The measurements of intraoperative kinematics were consisted of 3 points: femoral rotation angle (degree) and antero-posterior translation (mm), which were measured as the translation of the lowest points of femoral component to tibial cutting surface, and the joint gap difference between the medial and lateral components gap (mm). All joint kinematic data were recorded at every 10 degrees of flexion from maximum extension to flexion under anesthesia.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 292 - 292
1 Mar 2013
Okada Y Fujiwara K Endou H Ozaki T
Full Access

Purpose

Accolade TMZF® has the wedged taper shape and is fixed at the middle part. We testified the short term result of Accolade® and investigated the factor of subsidence.

Materials and Methods

We treated 21 hips in 20 patients (6 males and 15 females) with Accolade stem. The mean age was 61.2 years old (40–79 years old). The mean follow-up period was 11.1 months (6–23 months), and those within 5 months after operation were excluded. We measured the width of the stem and the canal of femur at the level of the upper and the lower end of lesser trochanter, and 1 cm above the tip of the stem at operation and at the last follow-up, then calculated the canal fill ratios. We also measured the distance between the tip of the stem and the proximal end of greater trochanter, then calibrated it by directly sizing the acetabular component. The value that subtracted the distance at the last follow-up from the distance at operation meant subsidence. We performed multiple regression study about weight and the canal fill ratio of stem at the level of lower end of lesser trochanter.