Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 315 - 315
1 Nov 2002
Safran O Ilsar I Leichter I Neeman V Liebergall M
Full Access

Introduction: Bone strength is determined by several factors including bone mineral density and the geometrical structure of bone tissue. Plain X-ray is not used regularly for bone mineral density measurements due to different x-ray exposure used for each patient. The different radiation energies have major effects on the optical density of the obtained films. Therefore dual energy X-ray absorptiometry (DEXA) is the golden standard for bone density estimation. However it is relatively expensive and relatively inaccessible.

Objective: To evaluate a new computerized analysis of digitized plain radiographs of the proximal femur to allow the evaluation of bone mineral density in human subjects.

Material and Methods: 14 people hospitalized for proximal femoral fracture had their uninvolved proximal femur BMD estimated with a DEXA in the 5 typical regions defined by the DEXA test. Plain proximal femur radiographs of these patients were taken with a standard wedge and digitized into the computer to generate a digital image. The gray levels in the digital image were analyzed and normalized to yield the mineral content at the 5 regions defined by DEXA. The data obtained were correlated with the DEXA results.

Results: The correlation between BMD (DEXA) and gray level measurement of the proximal femur (R=0.261) was not significant. This correlation was significantly improved after modification of the gray levels to 0.549 (P< 0.032).

Conclusion: This computerized analysis and modification of gray levels in digitized radiographs improved significantly the possibility to evaluate bone mineral density of the proximal femur from plain X-rays.