Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 127 - 127
1 Dec 2013
Mohan V Namba R Sheth D Paxton L Inacio M
Full Access

Background and Purpose:

Modularity of the tibial component in total knee arthroplasties (TKA) has many surgical benefits. It also reduces inventory related expenses but increases implant cost. The resulting locking mechanism micromotion that leads to non-articular microwear and has been an accepted consequence of modularity. The purpose of this study is to evaluate the risk of revision (all-cause and aseptic) of a monoblock all-polyethylene tibial component compared to a fixed bearing modular tibial construct with the same articular geometry while adjusting for potential confounders in a community based sample of primary TKAs. In addition, younger and older patient specific risk of revision was evaluated.

Method:

A retrospective analysis of prospectively collected data from a Total Joint Replacement Registry (TJRR) was conducted. All 27,657 primary TKAs enrolled between 2001 and 2010 performed for any diagnosis with the same implant from a single manufacturer were included in the study. Patient characteristics, as well as surgeon, hospital, procedure, and implant characteristics were compared by the main exposure of interest, i.e. the type of tibial prosthesis (monoblock all-polyethylene vs. metal-backed modular). The main endpoints of the study were all-cause and aseptic revisions only. Descriptive statistics and Cox-regression models were employed. Hazard ratios (HR) and 95% confidence intervals (CI) are provided.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 437 - 438
1 Apr 2004
Rasquinha V Mohan V Bevilacqua B Rodriguez J Ranawat C
Full Access

Introduction: Polyethylene wear debris is the main contributing factor that leads to aseptic loosening and osteolysis. The main objective of this study was to evaluate the role of hydroxyapatite (HA) in third-body polyethylene wear in total hip arthroplasty.

Materials: 199 primary cementless THA’s (174 patients) performed by a single surgeon were enrolled in a prospective randomized study comprising hydroxyapatite and non-hydroxyapatite coated femoral implants. The femoral component had metaphyseal-diaphyseal fit design with proximal plasma sprayed titanium circumferential porous coating. The hydroxyapatite coating was 50 – 75 micrometers over the porous surface with the components of identical design. The acetabular component was plasma sprayed titanium porous coated shell without hydroxyapatite. T he polyethylene liners were machined molded from ram extruded Hi-fax 1900H polyethylene resin gamma-sterilized in argon (inert) gas. Clinical and Radiographic evaluation was performed employing HSS scores and Engh criteria.

Results: At a mean follow-up of 5 years, the radiographs of 83 HA and 73 Non-HA hips were evaluated by two independent observers utilizing computer-assisted wear analysis on digitized standardized radiographs described by Martell et al (1997). The radiographs were also evaluated for osteolysis or aseptic loosening.

The mean linear wear rate in HA group was 0.19mm/yr and in the non-HA group was 0.21mm/yr, which was not significant (p> 0.05). There was no case of osteolysis or aseptic loosening of any component. Both groups had comparable outcomes in terms of HSS scores, walking ability and sports participation.

Discussion: This study has attempted to demonstrate through an appropriately controlled in vivo study that hydroxyapatite does not play a significant role in third-body polyethylene wear in THA at a mean follow-up of five years. The concern of three-body wear with hydroxyapatite coating is no greater than porous coated cementless implants.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 417 - 417
1 Apr 2004
Rasquinha V Mohan V Bevilacqua B Rodriguez J Ranawat C
Full Access

Introduction: Polyethylene wear debris is the main contributing factor that leads to aseptic loosening and osteolysis. The main objective of this study was to evaluate the role of hydroxyapatite (HA) in third-body polyethylene wear in total hip arthroplasty.

Materials: 199 primary cementless THA’s (174 patients) performed by a single surgeon were enrolled in a prospective randomized study comprising Hydroxyapatite and non-hydroxyapatite coated femoral implants. The femoral component had metaphyseal-diaphyseal fit design with proximal plasma sprayed titanium circumferential porous coating. The hydroxyapatite coating was 50 – 75 micrometers over the porous surface with the components of identical design. The acetabular component was plasma sprayed titanium porous coated shell without hydroxyapatite