Vol. 93-B, Issue SUPP_III | Pages 305 - 305
1 Jul 2011
Leighton R Dunbar M Petrie D Deluzio K O’Brien P Buckley R Powell J Mckee M Schmitsch E Stephen D Kreder H Harvey E Sanders D McCormack B Pate G Hawsawi A Evans A Persis R
Full Access

Introduction: Surgical fixation of intra-articular distal femoral fractures has been associated with nonunion & varus collapse. The soft tissuestripping associated with this fracture andthe surgical exposure have been factors associated with delayed union & infection. The limited soft tissue exposure has been lauded the as a solution to this fracture. However, it has occurred with the new fixation as well.(Locked Plate)

Aims: This study is an attempt to look at the fixation. Does the LISS system improve the results of this difficult fracture? Is there truly a difference in the outcome of this fracture utilizing the Locked plate system or is the percieved difference due to the surgical mini invasive approach.

Patients & Methods: One hunderd & forty patients were screened, only 53 were randomized and fixed in six academic centers over 5 years. All C3 fractures were excluded as they were felt not to be treatable by the DCS device, but they were treated appropiately. 35 females and 18 males were included in the study and randomized appropiatley.

Results: Fifty-three patients were randomized, 28 had the LISS implant and 25 had the DCS utilized. There were 3 nonunions in the LISS group plus two patients with early loss of reduction that required reoperation in the early post operative period. One patient developed arthrofibrosis requiring arthroscopic release and subsequently the implant failed necessitating refixation. In the DCS group, only one nonunion reported & required second surgery. This translated to a reoperation rate of 21% in the LISS group compared to 4% with DCS.

Conclusion: This prospective randomized multicentre trial showed a difference when comparing the LISS to the DCS in the supracondylar distal femur fractures.