header advert
Results 1 - 9 of 9
Results per page:
Applied filters
Content I can access

General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 57 - 57
1 Feb 2021
Elmasry S Chalmers B Sculco P Kahlenberg C Mayman D Wright T Westrich G Cross M Imhauser C
Full Access

Introduction

Surgeons commonly resect additional distal femur during primary total knee arthroplasty (TKA) to correct a flexion contracture to restore range of motion and knee function. However, the effect of joint line elevation on the resulting TKA kinematics including frontal plane laxity is unclear. Thus, our goal was to quantify the effect of additional distal femoral resection on passive extension and mid-flexion laxity.

Methods

Six computational knee models with capsular and collateral ligament properties specific to TKA were developed and implanted with a contemporary posterior-stabilized TKA. A 10° flexion contracture was modeled by imposing capsular contracture as determined by simulating a common clinical exam of knee extension and accounting for the length and weight of each limb segment from which the models were derived (Figure 1). Distal femoral resections of 2 mm and 4 mm were simulated for each model. The knees were then extended by applying the measured knee moments to quantify the amount of knee extension. The output data were compared with a previous cadaveric study using a two-sample two-tailed t-test (p<0.05) [1]. Subsequently, varus and valgus torques of ±10 Nm were applied as the knee was flexed from 0° to 90° at the baseline, and after distal resections of 2 mm, and 4 mm. Coronal laxity, defined as the sum of varus and valgus angulation in response to the applied varus and valgus torques, was measured at 30° and 45°of flexion, and the flexion angle was identified where the increase in laxity was the greatest with respect to baseline.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 72 - 72
1 Mar 2017
Aggarwal V Vigdorchik J Carroll K Jerabek S Mayman D
Full Access

Total hip arthroplasty (THA) is an effective operation for patients with hip osteoarthritis; however, patients with hip dysplasia present a particular challenge. Our novel study examined the effect of robotic-assisted THA in patients with hip dysplasia.. Nineteen patients at two centers presented with hip dysplasia. We found that components were placed according to the preoperative plan, there was a significant improvement in the modified Harris Hip Score from 31 to 84 (p<0.001), an improvement in hip range of motion (flexion improvement from 66 º to 91º, p<0.0001), a significant correction of leg length discrepancy (17.5 vs. 4 mm, p<.0002), and no short-term complications.. Robotic-assisted THA can be a useful method to ensure adequate component positioning and excellent outcomes in patients with hip dysplasia.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 32 - 32
1 May 2016
Carroll K Barlow B Mclawhorn A Esposito C Mayman D
Full Access

Introduction

Neutral mechanical alignment in TKA has been shown to be an important consideration for survivorship, wear, and aseptic loosening. However, native knee anatomy is described by a joint line in 3° of varus, 2–3° of mechanical distal femoral valgus, and 2–3° of proximal tibia varus. Described kinematic planning methods replicate native joint alignment in extension without changing tibiofemoral alignment, but do not account for native alignment through a range of motion. An asymmetric TKA femoral component with a thicker medial femoral condyle and posterior condylar internal rotation paired with an asymmetric polyethylene insert aligns the joint line in 3° of varus while maintaining distal femoral and proximal tibial cuts perpendicular to mechanical axis. The asymmetric components recreate an anatomic varus joint line while avoiding tibiofemoral malalignment or femoral component internal rotation, a risk factor for patellofemoral maltracking. The study seeks to determine how many patients would be candidates for a kinematically planned knee without violating the principle of a neutral mechanical axis (0° ± 3°).

Methods

A cohort comprised of 55 consecutive preoperative THA patients with asymptomatic knees and 55 consecutive preoperative primary unilateral TKA patients underwent simultaneous biplanar radiographic imaging. Full length coronal images from the thoracolumbar junction to the ankles were measured by two independent observers for the following: mechanical tibiofemoral angle (mTFA), mechanical lateral distal femoral angle (mLDFA), and mechanical medial proximal tibial angle (mMPTA). Patients who met the following conditions: mTFA 0°±3°; mLDFA 87°±3°; and mMPTA 87°±3°, were considered candidates for TKA with an asymmetric implant that would achieve a kinematic joint line and neutral mechanical axis. Similarly, patients with the following conditions: mTFA 0°±3°; mLDFA 90°±3°; and mMPTA 90°±3°, were considered candidates for TKA with a symmetric implant that would achieve a kinematic joint line and neutral mechanical axis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 71 - 71
1 May 2016
Carroll K Barlow B Esposito C Lipman J Padgett D Mayman D Jerabek S
Full Access

Introduction

The longevity of total hip arthroplasty (THA) is dependent on acetabular component position. We measured the reliability and accuracy of a CT-based navigation system to achieve the intended acetabular component position and orientation using three dimensional imaging. The purpose of the current study was to determine if the CT-guided robotic navigation system could accurately achieve the desired acetabular component position (center of rotation (COR)) and orientation (inclination and anteversion). The postoperative orientation and location of the components was determined in 20 patients undergoing THA using CT images, the gold standard for acetabular component orientation.

Methods

Twenty primary unilateral THA patients were enrolled in this IRB-approved, prospective cohort study to assess the accuracy of the robotic navigation system. Pre- and post-operative CT exams were obtained and aligned 3D segmented models were used to measure the difference in center of rotation and orientation (anteversion and inclination). Patients with pre-existing implants, posttraumatic arthritis, contralateral hip arthroplasty, septic arthritis, or previous hip fracture were excluded. All patients underwent unilateral THA using robotic arm CT-guided navigation (RIO Makoplasty; MAKO Surgical Corp).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 135 - 135
1 May 2016
Kia M Imhauser C Warth L Lipman J Westrich G Cross M Mayman D Pearle A Wright T
Full Access

Introduction

Medial unicompartmental knee arthroplasty (UKA) restores mechanical alignment and reduces lateral subluxation of the tibia. However, medial compartment translation remains abnormal compared to the native knee in mid-flexion Intra-operative adjustment of implant thickness can modulate ligament tension and may improve knee kinematics. However, the relationship between insert thickness, ligament loads, and knee kinematics is not well understood. Therefore, we used a computational model to assess the sensitivity of knee kinematics, and cruciate and collateral ligament forces to tibial component thickness with fixed bearing medial UKA.

Methods

A computational model of the knee with subject-specific bone geometries, articular cartilage, and menisci was developed using multibody dynamics software (Fig 1a). The ligaments were represented with multiple non-linear, tension-only force elements, and incorporated mean structural properties. The 3D geometries of the femoral and tibial components of the Stryker Triathlon fixed-bearing UKA were captured using a laser scanner. An arthroplasty surgeon aligned the femoral and tibial components to the articular surfaces within the model (Fig 1b). The intact and UKA models were passively flexed from 0 to 90° under a 10 N compressive load. The tibial polyethylene insert was modeled by the orthopaedic surgeon to create a “balanced” knee. The modeled polyethylene insert thickness was then increased by 2 mm and decreased 2mm (in increments of 1mm) to simulate over- and under-stuffing, respectively. Outcomes were anterior-posterior (AP) translation of the femur on the tibia in the medial compartment, and forces seen by the ACL and MCL during mid-flexion (from 30 to 60° flexion). The mean differences between the intact knee model and all other experimental conditions for each outcome were calculated across mid-flexion.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 27 - 27
1 May 2016
Carroll K Patel A Carli A Cross M Jerabek S Mayman D
Full Access

Introduction

While implant designs and surgical techniques have improved in total knee arthroplasty (TKA), approximately 20% of patients remain dissatisfied. The purpose of this study was to determine if reproduction of anatomic preoperative measurements correlated to improved clinical outcomes in TKA.

Methods

We retrospectively reviewed95 patients (106 knees) who underwent a TKA between 2012 −2013 with a minimum of one year follow-up. All patients had a pre and post-operative SF-12 and WOMAC scores. Pre and 6 week post-operative radiographs were reviewed to compare restoration of coronal plane alignment, maintenance of joint line obliquity, and maintenance of tibial varus. Coronal alignment was defined as the angle formed between the mechanical axis of the femur and the the tibia. Joint line obliquity was defined as the angle between the mechanical axis of the limb and the line which best parallels the joint space at the knee. Tibial varus was compared between the preoperative proximal lateral tibial angle and the angle formed by the mechanical axis of the tibia and tibial component postoperatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 129 - 129
1 May 2016
Carroll K Esposito C Miller T Lipman J Padgett D Jerabek S Mayman D
Full Access

Introduction

Implant position plays a major role in the mechanical stability of a total hip replacement. The standard modality for assessing hip component position postoperatively is a 2D anteroposterior radiograph, due to low radiation dose and low cost. Recently, the EOS® X-Ray Imaging Acquisition System has been developed as a new low-dose radiation system for measuring hip component position. EOS imaging can calculate 3D patient information from simultaneous frontal and lateral 2D radiographs of a standing patient without stitching or vertical distortion, and has been shown to be more reliable than conventional radiographs for measuring hip angles[1]. The purpose of this prospective study was to compare EOS imaging to computer tomography (CT) scans, which are the gold standard, to assess the reproducibility of hip angles.

Materials and Methods

Twenty patients undergoing unilateral THA consented to this IRB-approved analysis of post-operative THA cup alignment. Standing EOS imaging and supine CT scans were taken of the same patients 6 weeks post-operatively. Postoperative cup alignment and femoral anteversion were measured from EOS radiographs using sterEOS® software. CT images of the pelvis and femur were segmented using MIMICS software (Materialise, Leuven, Belgium), and component position was measured using Geomagic Studio (Morrisville, NC, USA) and PTC Creo Parametric (Needham, MA). The Anterior Pelvic Plane (APP), which is defined by the two anterior superior iliac spines and the pubic symphysis, was used as an anatomic reference for acetabular inclination and anteversion. The most posterior part of the femoral condyles was used as an anatomic reference for femoral anteversion. Two blinded observers measured hip angles using sterEOS® software. Reproducibility was analysed by the Bland-Altman method, and interobserver reliability was calculated using the Cronbach's alpha (∝) coefficient of reliability.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 42 - 42
1 Oct 2014
Maratt J Esposito C McLawhorn A Carroll K Jerabek S Mayman D
Full Access

Sagittal pelvic tilt (PT) has been shown to effect the functional position of acetabular components in patients with total hip replacements (THR). This change in functional component position may have clinical implications including increased likelihood of wear or dislocation. Surgeons can use computer-assisted navigation intraoperatively to account for a patient's pelvic tilt and to adjust the position of the acetabular component. However, the accuracy of this technique has been questioned due to the concern that PT may change after THR. The purpose of this study was to measure the change in PT after THR, and to determine if preoperative clinical and radiographic parameters can predict PT changes after THR.

138 consecutive patients who underwent unilateral THR by one surgeon received standing bi-planar lumbar spine and lower extremity radiographs preoperatively and six weeks postoperatively. Patients with prior contralateral THR, conversion THR and instrumented lumbosacral fusions were excluded. PT and pelvic incidence (PI) were measured preoperatively for each patient, and PT was measured on the postoperative imaging. A negative value for PT indicated posterior pelvic tilt. Patient demographics were collected from the chart.

Average age was 56.8±10.9 years, average BMI was 28.3±6.0 kg/m2, and 67 patients (48.6%) were female. Mean preoperative pelvic tilt was 0.6°±7.3° (range: −19.0° to 17.9°). We found greater than 10° of sagittal PT in 23 out of 138 (16.6%) patients in this sample. Mean post-operative pelvic tilt was 0.3°±7.4° (range: −18.4° to 15.0°). Mean change in pelvic tilt was −0.3°±3.6° (range: −9.6° to 13.5°). PT changed by less than 5° in 119 of 138 patients (86.2%). The mean difference in pre-operative and post-operative PT is not statistically significant (p = 0.395). Pre-operative PT was strongly correlated with post-operative PT (r2 = 0.88, p = 0.0001) (Figure 1). There was not a statistically significant relationship between PI and change in PT (r2 = −0.16, p = 0.06).

In conclusion, based on the variability in pelvic tilt in this study population and the relatively small change in pelvic tilt following THA tilt-adjustment of the acetabular component position based on standing pre-operative imaging is likely to be of benefit in the majority of patients undergoing navigated THA. However, we have been unable to predict the relatively rare occurrence of a large change in pelvic tilt, which would confound tilt-adjusted component position.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 63 - 63
1 Aug 2013
Klingenstein G Cross M Plaskos C Li A Nam D Lyman S Pearle AD Mayman D
Full Access

Introduction

The aim of this study was to quantify mid-flexion laxity in a total knee arthroplasty with an elevated joint line, as compared to a native knee and a TKA with joint line maintained. Our hypothesis was joint line elevation of 4mm would increase coronal plane laxity throughout mid-flexion in a pattern distinct from the preoperative knee or in a TKA with native joint line.

Methods

Six fresh-frozen cadaver legs from hip-to-toe underwent TKA with a posterior stabilised implant (APEX PS, OMNIlife Science, Inc.) using a computer navigation system equipped with a robotic cutting-guide, in this controlled laboratory cadaveric study. After the initial tibial and femoral resections were performed, the flexion and extension gaps were balanced using navigation, and a 4mm recut was made in the distal femur. The remaining femoral cuts were made, the femoral component was downsized by resecting an additional 4mm of bone off the posterior condyles, and the polyethylene was increased by 4mm to create a situation of a well-balanced knee with an elevated joint line. The navigation system was used to measure overall coronal plane laxity by measuring the mechanical alignment angle at maximum extension, 30, 45, 60 and 90(of flexion, when applying a standardised varus/valgus load of 9.8Nm across the knee using a 4kg spring-load located at 25cm distal to the knee joint line. Laxity was also measured in the native knee, as well as the native knee after a standard approach during TKA which included a medial release. Coronal plane laxity was defined as the absolute difference (in degrees) between the mean mechanical alignment angle obtained from applying a standardised varus and valgus stress at 0, 30, 45, 60 and 90(.