Reddy G Stritch P Manning M Gudena R Emms N
Full Access

Background

Revision total hip arthroplasty is a technically demanding procedure and especially removing a well fixed femoral stem is a challenge for revision surgeons. There are various types of trochanteric osteotomies used during revision surgery; extended trochanteric osteotomy (ETO) is being more popular.

Aim

The aim of this study is to look at types of trochanteric osteotomy used during the revision surgery. We looked at the success and failure of these osteotomies. Failure of the osteotomy is defined by complete pull off by the hip abductors resulting in osteotomy fragment is no contact with the femur. We sought to assess the time to healing of osteotomy and number of cables used.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 37 - 37
1 Sep 2012
Patil S Manning M Mizu-uchi H Ezzet K D'Lima D
Full Access

Introduction

It is well known that total knee arthroplasty (TKA) does not preserve normal knee kinematics. This outcome has been attributed to alteration of soft-tissue balance and differences between the geometry of the implant design and the normal articular surfaces. Bicompartmental knee arthroplasty (BKA) has been developed to replace the medial and anterior compartments, while preserving the lateral compartment, the anterior cruciate ligament (ACL), and the posterior cruciate ligament (PCL). In a previous study, we reported that unicompartmental knee arthroplasty did not significantly change knee kinematics and attributed that finding to a combination of preservation of soft-tissue balance and minimal alteration of joint articular geometry (Patil, JBJS, 2007). In the present study, we analyzed the effect of replacing trochlear surface in addition to the medial compartment by implanting cadaver knees with a bicompartmental arthroplasty design. Our hypothesis was that kinematics after BCKA will more closely replicate normal kinematics than kinematics after TKA.

Methods

Eight human cadaveric knees underwent kinematic analysis with a surgical navigation system. Each knee was evaluated in its normal intact state, then after BKA with the Deuce design (Smith & Nephew, Memphis, TN), then after ACL sacrifice, and finally after implanting a PCL-retaining TKA (Legion, Smith & Nephew). Knees were tested on the Oxford knee rig, which simulates a quadriceps-driven dynamic deep knee bend. Tibiofemoral rollback and rotation and patellofemoral shift and tilt were recorded for each condition and compared using repeated measures ANOVA for significance.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 31 - 31
1 Jan 2011
Cohen D Chapman E Sarkar S Manning M
Full Access

Over 200,000 osteoporotic fractures occur in the UK annually. Patients with fragility fractures are at highest risk of further fracture, though preventative treatment has been shown to reduce subsequent fracture incidence. In 2005, the National Institute for Health & Clinical Excellence (NICE) recommended bisphosphonates as a treatment option in women over 75 years without the need for prior DEXA scanning (Technology Appraisal Guidance 87). We prospectively reviewed the medication of such patients who were admitted to our Trauma Unit to identify if the NICE guidance was being followed.

Over a three month period between May and July 2007, 54 women over 75 years old were discharged from our Trauma Unit having sustained an osteoporotic fracture. We prospectively reviewed their medication to identify if a bisphosphonate had been commenced by the General Practitioner and their discharge letters to their General Practitioners to see if it had been suggested to start one. 7 of the 54 women (13%) were already on a bisphosphonate and were therefore excluded.

Only one (2%) of the discharge letters (written by the Orthopaedic doctor to the General Practitioner) recommended commencing a bisphosphonate. 6 of the 47 patients (13%) had been started on a bisphosphonate by the General Practitioner.

Nice guidance from 2005 is clearly not being implemented in our area. A minority of patients will have contraindications or allergies to bisphosphonates (up to 1 in 4 patients as highlighted recently by the National Osteoporosis Society). Important deficiencies in local services have been identified, particularly with respect to communication between secondary and primary care. This study lead to an education initiative to ensure the Trauma department and our local General Practitioners were aware of the NICE guidance. A second prospective audit is currently being undertaken to assess the effect on our service.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 331 - 331
1 May 2010
Cohen D Chapman E Sarkar S Manning M
Full Access

Introduction: Over 200,000 osteoporotic fractures occur in the UK annually. Patients with fragility fractures are at highest risk of further fracture, though preventative treatment has been shown to reduce subsequent fracture incidence. In 2005, the National Institute for Health & Clinical Excellence (NICE) recommended bisphosphonates as a treatment option in women over 75 years without the need for prior DEXA scanning (Technology Appraisal Guidance 87).

We prospectively reviewed the medication of such patients who were discharged from our Trauma Unit to identify if the NICE guidance was being followed.

Method: Over a three month period between May and July 2007, 54 women over 75 years old were discharged from our Trauma Unit having sustained an osteoporotic fracture.

We prospectively reviewed their medication to identify if a bisphosphonate had been commenced by the General Practitioner and their discharge letters to their General Practitioners to see if it had been suggested to start one.

Results: 7 of the 54 women (13%) were already on a bisphosphonate and were therefore excluded.

Only one (2%) of the discharge letters (written by the Orthopaedic doctor to the General Practitioner) recommended commencing a bisphosphonate.

6 of the 47 patients (13%) had been started on a bisphosphonate by the General Practitioner.

Conclusions: Nice guidance from 2005 is clearly not being implemented in our area. Some patients will have contraindications or allergies to bisphosphonates, however, they will be a minority (up to 1 in 4 patients as highlighted recently by the National Osteoporosis Society).

We believe the results demonstrate a lack of health promotion opportunities to prevent future fracture. Although there is clear focus and impetus for developing falls prevention services nationwide, this enthusiasm has not been translated across to bone health, despite the potential savings in terms of morbidity, mortality and healthcare costs.

Important deficiencies in local services have been identified, particularly with respect to communication between secondary and primary care.

This study lead to an education initiative to ensure the Trauma department and our local General Practitioners were aware of the NICE guidance. A second prospective audit is currently being undertaken to assess the effect on our service.