Vol. 94-B, Issue SUPP_XXXVII | Pages 69 - 69
1 Sep 2012
Hernigou P Poignard A Lachaniette CHF Filippini P
Full Access

Total hip arthroplasty (THA) has been efficacious for treating hip fractures. However, in these patients with fractures a widely variable prevalence of dislocation has been reported, partly because of varying durations of follow-up for this specific end-point. The purpose of the present study was to determine the risk of dislocation as a function of time after total hip arthroplasty in these patients with fractures and to investigate if constrained liners influence the cumulative risk of dislocation.

Between 2000 and 2005, 425 patients with neck fracture underwent primary THA using a constrained acetabular liner (Cemented retentive cup, Groupe lépine, Genay, France). The results of these 425 constrained acetabular liners were compared with 380 THA without constrained liners performed for neck fractures between 1994 and 1999 in the same hospital. All patients were followed for a minimum of 5 years for radiographic evidence of implant failure. The patients were followed at routine intervals and were specifically queried about dislocation. The cumulative risk of dislocation was calculated with use of the Kaplan-Meier method.

Results

For patients without constrained liners, the cumulative risk of a first-time dislocation was 5% at one month and 12% at one year and then rose at a constant rate of approximately 2% every five years to 17% at five years, 19% at ten years, 21% at 15 years for patients who were alive and had not had a revision by that time. For patients with constrained liners, the cumulative risk of a first-time dislocation was 1% at one month, 2% at one year and then did not changed at 5 years and at 10 years for patients who were alive and had not had a revision by that time. Multivariate analysis revealed that the relative risk of dislocation for female patients (as compared with male patients) was 2.1 and that the relative risk for patients who were 80 years old or more (as compared with those who were less than 80 years old) was 1.5. Two underlying diagnoses - cognitively impaired patients or neurologic desease—were also associated with a significantly greater risk of dislocation. At minimum 7 year follow up (range 5 10 yrs), there were 8 radiographic failures (dislocations) of the 425 constrained liners (2%), and no loosenings were noted.

Conclusions

The cumulative long-term risk of dislocation for patients with hip fractures is considerably greater than has been reported in short-term studies. The incidence of dislocation is highest in the first year after arthroplasty and then continues at a relatively constant rate for the life of the arthroplasty. Patients at highest risk are old female patients and those with a diagnosis of neurologic desease. Constrained liners in these patients is an efffective technique to prevent post operative hip dislocation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 68 - 68
1 Sep 2012
Hernigou P Poignard A Lachaniette CHF
Full Access

Introduction

This study reports the results of percutaneous autologous bone marrow grafting in 62 patients with corticosteroids treatment who had one hip osteonecrosis treated with bone marrow (BM) injection and the other contralateral hip osteonecrosis with core decompression (CD) alone. Only patients with bilateral symptomatic osteonecrosis and with those hips at stage I or II (as defined by Steinberg) were included in this study.

Material and Methods

Between 1988 and 1995, 62 consecutive patients (28 males and 34 females) were included in this study. These patients had a mean age of 31 years (range 18 to 34 years) at the time of the onset of symptoms. The average follow-up was 17 years (range, 15 to 20 years). An average of 152 + 16 milliliters of marrow was aspirated from the iliac crest. The number of stroma progenitor that was transplanted was estimated by counting the Fibroblast Colony Forming Units which express type I and type III collagen. The bone marrow graft obtained after concentration contained average 4889 + 716 progenitors per cubic centimeter (range 3515 to 6293 per cubic centimeter). Each hip received a mean number of thirty cubic centimeters of bone marrow graft (range 27 to 35 cubic centimeters). The average total number of CFU-F injected in each hip was therefore 147 × 103 cells (range 119 × 103 to 195 × 103 cells).