Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Bone & Joint Research
Vol. 7, Issue 5 | Pages 327 - 335
1 May 2018
Sato Y Akagi R Akatsu Y Matsuura Y Takahashi S Yamaguchi S Enomoto T Nakagawa R Hoshi H Sasaki T Kimura S Ogawa Y Sadamasu A Ohtori S Sasho T

Objectives

To compare the effect of femoral bone tunnel configuration on tendon-bone healing in an anterior cruciate ligament (ACL) reconstruction animal model.

Methods

Anterior cruciate ligament reconstruction using the plantaris tendon as graft material was performed on both knees of 24 rabbits (48 knees) to mimic ACL reconstruction by two different suspensory fixation devices for graft fixation. For the adjustable fixation device model (Socket group; group S), a 5 mm deep socket was created in the lateral femoral condyle (LFC) of the right knee. For the fixed-loop model (Tunnel group; group T), a femoral tunnel penetrating the LFC was created in the left knee. Animals were sacrificed at four and eight weeks after surgery for histological evaluation and biomechanical testing.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 397 - 398
1 Apr 2004
Urabe K Miura H Kuwano T Nagamine R Matsuda S Sasaki T Kimura S Iwamoto Y Itoman M
Full Access

We evaluated the geometry of the resected femoral surface according to the theory for total knee arthroplasty (TKA) using three-dimensional computed tomography (3D CT).

The 3D CT scans were performed in 44 knees indicated as requiring total knee arthroplasty. The 3D images of the femurs were clipped according to the following procedures. The distal femur was cut perpendicular to the mechanical axis at 10 mm proximal from the medial condyle. Rotational alignment was fixed at 3 degrees external rotation from the posterior condylar line. The anterior condyle was resected using the anterior cortex as the reference point. The posterior condyle was cut at 10 mm anterior from the medial posterior condyle.

The medial-lateral (ML) width/anterior-posterior (AP) length was 1.58 ± 0.14 (mean ± SD). AP length of the 3D images tended to be longer than the box length of the three kinds of components provided when the ML width of the images was approximately equal to that of each component. The widths of medial and lateral posterior condyles of the images were 30.1 ± 3.8 mm and 24.8 ± 3.0 mm, respectively. In all except one case, the widths of the resected medial posterior condyles were greater than those of the medial condyles of all components when those of resected lateral posterior condyles were equal to those of the lateral condyles of the components.

The shapes of the resected femoral surface did not always match those of the components. The configuration of Japanese knee joints is different from that of American knee joints. Components with appropriate geometry should be designed for Japanese patients.