header advert
Results 1 - 1 of 1
Results per page:
Applied filters
Content I can access

General Orthopaedics

Include Proceedings
Dates
Year From

Year To

Increasing expectations from arthroscopic anterior cruciate ligament (ACL) reconstructions require precise knowledge of technical details such as minimum intra-femoral tunnel graft lengths. A common belief of having ≥20mm of grafts within the femoral tunnel is backed mostly by hearsay rather than scientific proof.

We examined clinico-radiological outcomes in patients with intra-femoral tunnel graft lengths <20 and ≥20mm. Primary outcomes were knee scores at 1-year. Secondarily, graft revascularization was compared using magnetic resonance imaging (MRI). We hypothesized that outcomes would be independent of intra-femoral tunnel graft lengths.

This prospective, single-surgeon, cohort study was conducted at a tertiary care teaching centre between 2015–2018 after obtaining ethical clearances and consents. Eligible arthroscopic ACL reconstruction patients were sequentially divided into 2 groups based on the intra-femoral tunnel graft lengths (A: < 20 mm, n = 27; and B: ≥ 20 mm, n = 25). Exclusions were made for those > 45 years of age, with chondral and/or multi-ligamentous injuries and with systemic pathologies. All patients were postoperatively examined and scored (Lysholm and modified Cincinnati scores) at 3, 6 and 12 months. Graft vascularity was assessed by signal-to-noise quotient ratio (SNQR) using MRI. Statistical significance was set at p<0.05.

Age and sex-matched patients of both groups were followed to 1 year (1 dropout in each). Mean femoral and tibial tunnel diameters (P =0.225 and 0.595) were comparable. Groups A (<20mm) and B (≥20mm) had 27 and 25 patients respectively. At 3 months, 2 group A patients and 1 group B patient had grade 1 Lachman (increased at 12 months to 4 and 3 patients respectively). Pivot shift was negative in all patients. Lysholm scores at 3 and 6 months were comparable (P3= 0.195 and P6= 0.133). At 1 year both groups showed comparable Cincinnati scores. Mean ROM was satisfactory (≥130 degrees) in all but 2 patients of each group (125–130 degrees). MRI scans at 3 months and 1 year observed anatomical tunnels in all without any complications. Femoral tunnel signals in both groups showed a fall from 3–12 months indicating onset of maturation of graft at femoral tunnel.

Our hypothesis, clinical and radiological outcomes would be independent of intra-tunnel graft lengths on the femoral aspect, did therefore prove correct. Intra-femoral tunnel graft lengths of <20 mm did not compromise early clinical and functional outcomes of ACL reconstructions. There seems to be no minimum length of graft within the tunnel below which suboptimal results should be expected.