The purpose of this study was to determine the efficacy of a multi-modal blood conservation protocol that involved pre–operative autologous blood donations (2 units) in conjunction with erythropoietin supplementation as well as intra-operative conservation modalities. A retrospective chart review of 90 patients with simultaneous bilateral total knee arthroplasty done between 2006–2009 by one of the 3 senior authors was performed. Patients donated two units of blood 4 weeks prior to surgery and also received erythropoietin injections (40,000 units: 3 weeks, 2 weeks and 1 week prior to surgery). Intra- operative blood management included use of pneumatic tourniquet, re-infusion drains, local epinephrine injections and fibrin spray. Post-operatively, autologous transfusions were provided based on symptoms. Pre-donation blood levels, peri-operative hemoglobin and hematocrit levels along with transfusion records were assessed.Introduction
Methods