In a prospective and randomised clinical study, acetabular cups were implanted free-hand (control group n=25) or with computer assistance using an image-free navigation system (study group n=25). Total hip replacement was performed in lateral position and through minimally invasive anterior approach (MicroHip). The cup position was measured postoperatively on pelvic CT using the CT-planning software. An average inclination of 42.3° (range: 35°–56°; SD±8.0°) and an average anteversion of 24.0° (range: −5° to 54°; SD±16.0°) were found in the control group, and an average inclination of 45.0° (range: 40°–50°; SD±2.8°) and an average anteversion of 14.4° (range: 5°–25°; SS±5.0°) in the computer-assisted study group. The deviations from the desired cup position (45° inclination, 15° anteversion) were significantly lower in the computer-assisted study group (p<
0.001 each). While only 10/25 of the cups in the control group were within the Lewinnek safe zone, 18/25 of the cups in the study group were placed in this target region (p=0.003). We saw no disadvantage compared to previous studies in supine position with standard approach.
The accuracy of component implantation is an important factor affecting long term results of unicompartmental knee replacement (UKR), particularly, since overcorrection of the leg axis has been associated with an inferior patients outcome. This problem is aggravated when using a minimally invasive approach with a limited view. In a prospective study, two groups of 40 UKR each were operated either using a non-image-based navigation system or the conventional technique. Radiographic assessment of postoperative alignment was performed by postoperative long-leg coronal and lateral x-rays. The results revealed a significant difference between the two groups in favour of navigation with regard to the mechanical axis, as well as the coronal femoral and tibial alignment. In the computer assisted group 38/40 (95%) of UKR were in a range of 4 Degree to 0 degree varus (mechanical axis) compared with 29/40 (72,5%) in the conventional group. There was no significant difference between the groups concerning postoperative range of motion, blood loss and pain score. The only inconvenience was a lengthening of the operation time (20 min). Due to the limited exposure in minimal invasive unicompartmental TKA the navigation system is helpful in achieving a more precise component orientation. The danger of overcorrection is diminished by real time information about the leg axis at each step during the operation. This improvement could be related to a longer survival rate.