Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 289 - 289
1 Sep 2012
Bragdon C Martell J Jarrett B Clohisy J White R Goldberg V Della Valle C Berry D Johanson P Harris W Malchau H
Full Access

Introduction

Total hip replacements using highly cross-linked polyethylene show excellent clinical outcomes, low wear, and minimal lysis at 5 years follow-up. A recent RSA study reports a significant increase in femoral head penetration between 5 and 7 years. This study is a multi-center radiographic analysis to determine whether the RSA observation is present in a large patient cohort.

Methods

Six centers were enrolled for radiographic analysis of primary total hip arthroplasty for standard head sizes (26mm, 28mm, or 32mm). Radiographic inclusion criteria required a minimum of four films per patient at the following time points: 1 year; 2–4.5 years; 4.5–5.5 years; and 5.5–11 years. The Martell Hip Analysis Suite was used to analyze pelvic radiographs resulting in head penetration values. Wear rates were determined in two ways: the longest follow-up radiograph compared to the 1 year film, and individual linear regressions for the early and late periods. For both methods, average wear rates from the early period (1 to 5.5 years) and late period (>5.5 years) were compared using t-tests.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 88 - 89
1 May 2011
Malchau H Callanan M Bragdon C Zurakowski D Jarrett B Rubash H
Full Access

There are a variety of patient and surgical factors shown to increase post-operative complication risk for a total hip arthroplasty (THA). While many studies have linked patient and surgical factors to unsuccessful outcomes post total hip arthroplasty (THA), no study has attempted to correlate the infiuence of these factors to the positioning of the acetabular cup. The purpose of this study was to determine if a correlation exists between patient and surgical factors and the anatomical position of the acetabular component.

Data for 2063 patients from 2004–2008 who underwent a primary total hip arthroplasty (THA), revision THA, or Birmingham Hip Resurfacing procedure was compiled. The post- op anteroposterior pelvis (AP) and the cross table lateral digital radiographs for each patient were measured to determine cup inclination and version. Acceptable angle ranges were defined as 30–45° for abduction, and 5–25° for version. Correlations between variables and cup abduction and version angles were determined with SPSS™ statistical software.

There were 1954(95%) qualifying patients. There were 1218(62%) acetabular cups that fell within the 30–45° optimal abduction range, and 1576(87%) cups in the 5–25° optimal version range. There were 921(47%) patients that had both inclination and version angles that fell within the optimal range. Regression analysis showed that surgical approach (p> 0.001), high/low volume surgeon (p< 0.001), and obesity (BMI > 30, p=0.01) were independent predictors for abduction and version combined analysis. Both surgical approach (p< 0.001) and BMI (p=0.018) were independent predictors in the individual analysis of both abduction and version. High/low volume surgeon was significant for the independent analysis of abduction (p=0.013). In the combined analysis, low volume surgeons showed a 2 fold increase (95% C.I. 1.5–2.8) in risk for cup malpositioning compared to high volume surgeons. The MIS surgical approach showed a 6 fold increase (95% C.I. 3.5–10.7) in risk for cup malpositioning compared to the posterolateral approach. Obesity (BMI> 30) showed a 1.3 fold increase (95% C.I. 1.1–1.7) in risk for cup malpositioning compared to all other body mass index groups.

Posterolateral surgical approach was superior to MIS surgical approaches for independent and combined abduction and version analysis. High volume surgeons had greater accuracy for cup positioning, specifically for achieving optimal cup abduction angle. Compared to all other body mass index categories, patients that were obese (BMI> 30) displayed a greater risk for cup malpositioning for independent and combined abduction and version analysis. Further statistical analyses on patient and surgical variables and their infiuence on cup position at a lower volume medical center would provide a valuable data comparison.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 126 - 126
1 May 2011
Bragdon C Martell J Clohisy J White R Goldberg V Della Valla C Berry D Jarrett B Harris W Malchau H
Full Access

Studies of patients having primary THR using highly cross-linked polyethylene show excellent clinical outcomes and very low radiographic wear results at a minimum of 5 years follow-up. Recently, a radiostereometric analysis (RSA) study of a small group of patients reported that after no detectable wear during years 1–5, they found a significant increase in femoral head penetration between 5 and 7 years follow-up. However, this increase in head penetration after 5 years has not been confirmed in a larger patient cohort.

The purpose of this study was to organize a multicenter radiographic study involving leading medical centers in the U.S. having the longest-term follow-up available on this type of highly cross-linked polyethylene in order to determine if the RSA observation can be confirmed in a larger study.

Six academic centers agreed to contribute radiographic data to this study. All patients received primary total hip replacements with Longevity polyethylene liners (Zimmer, Warsaw, IN) coupled with 26, 28, and 32mm cobalt chrome femoral heads. The radiographic inclusion criteria required a minimum of four radiographs per patient: one at 1 year; at least one from 2 to 4.5 years; one 4.5 to 5.5 years; and at least one from 5.5 to 9 years follow-up. The Martell Hip Analysis Suit-eTM software was used for the wear analysis. All wear values were determined by calculating head penetration between the follow-up radiograph and the 1-year radiograph to remove creep, the majority of which has been shown to occur during the first year. Separate linear regressions, representing the wear rates, were computed for the early period from 1 year to 5.5 years and the late period from 5.5 years to 9 years follow-up. The Zar test was used to determine the significance of the difference between these two linear regressions.

We present the completed analysis of 165 hips. When the early and late data points were combined into one data set, the second-order regression indicated an inflection point at 6.3 years with a slightly positive inflection. There were 402 film comparisons in the early time period, and the slope and confidence interval of the regression line was 4.9μm/yr (95% CI of −28μm/yr to 38μm/yr). There were 188 film comparisons in the late period, and slope of the regression line for the late period was 10.8 μm/yr (95% CI of −58μm/yr to 80μm/yr). The Zar test showed no significant difference between the two slopes (Figure 1, p=0.886).

No significant increase in femoral head penetration was found for the late period after 5 years compared to the early period before 5 years follow-up in either analysis. Additionally, no significant late increase in wear was seen within individuals. While we continue to enroll patients, at this time we do not observe the increase in wear seen in the RSA study after 5 years.