After THR, trochanteric soft tissue abnormalities may be associated with residual trochanteric pain and limping. However, normal MR appearance of the trochanteric region after THR is not known. The aim was to evaluate MR imagings in asymptomatic and symptomatic patients after THR through a transgluteal approach. Triplanar MR images of 25 asymptomatic (14 men, mean age 60.4 years, 11 women, mean age 60.2) and 49 symptomatic patients (19 men, mean age 62.7 years, 20 women, mean age 64.3) at least 1 year after THR were analyzed by two blinded radiologists. In 14 symptomatic patients MR imaging was correlated to surgical findings. Tendon defects were uncommon in asymptomatic and significantly more frequent in symptomatic patients (gluteus minimus 8% vs. 56%, p<
0.001; lateral gluteus medius 16% vs 62%, p<
0.001; posterior gluteus medius 0% vs18%, p<
0.025). Signal changes within tendons were very frequent in both groups except for the posterior gluteus medius tendon which demonstrated this finding more frequently in symptomatic patients (20% vs 59%, p=0.002). Changes in tendon diameter were very frequent in both groups but significantly (p=0.001–009) more frequent in symptomatic patients. Fatty atrophy was evident in the anterior two thirds of the gluteus minimus muscle in both asymptomatic and symptomatic patients. In the posterior superior third of the gluteus minimus muscle differences of fatty degeneration were significant. Fatty atrophy of the gluteus medius muscle was only present in symptomatic patients. Bursal fluid collections were more frequent in asymptomatic (32% vs 62%, p=0.021). MR diagnosis was confirmed in all 14 patients undergoing revision surgery. Although more frequent in symptomatic patients many MR findings are frequently found in asymptomatic patients. However, defects of the abductor tendons and fatty atrophy of the gluteus medius and the posterior part of the gluteus minimus muscle are rare in asymptomatic patients.
The practice of rotator cuff repair rapidly moves towards arthroscopic techniques especially for single tendon tears. Although the clinical results are relatively well established, the structural results of open rotator cuff repair and their correlation with the clinical outcome are poorly known. In order to provide a baseline for future studies using other repair techniques, this study was carried out to assess the structural changes in the repaired musculotendinous unit and to correlate these findings with the clinical outcome after rupture and repair of an isolated full thickness single tendon tear of the rotator cuff. To prospectively assess the quality of an open rotator cuff tendon repair technique, to determine how structural changes of rotator cuff muscles are affected by tendon repair, and to correlate the structural results of MRI studies with the clinical outcome. Direct open repair of a complete, isolated single tendon tear of the rotator cuff resulted in significant improvement in function and objective evidence of tendon healing on MRI. Successful direct repair was not associated with recovery of preoperative muscular atrophy or fatty infiltration when comparing Goutallier stage fatty infiltration between pre and postoperative patients. The age and gender-adjusted Constant score increased significantly from an average of 63.9% preoperatively to 94.5% postoperatively (p<
0.0001). Pain improved significantly from 6.8 points to 13.2 points on a visual analogue scale. (p<
0.0001). Activities of daily living increased from 11.2 points preoperatively to 17.9 points postoperatively (p<
0.0001). Anterior elevation, abduction and internal rotation improved significantly for subscapularis and supraspinatus repairs, but there was no significant change in external rotation. The overall rerupture rate was 12.5%. There was no significant improvement or recovery of muscular atrophy or fatty infiltration after tendon repair. Thirty-two consecutive open repairs of a single tendon tear of the rotator cuff were analysed. The supraspinatus tendon was involved in twenty-two patients and the subscapularis tendon in ten patients. All tendons were repaired using an open technique, a modified Mason-Allen suturing technique, and transosseus fixation with non-absorbable suture material knotted over a bone augmentation device.
The purpose of this study was to analyse a potential correlation of arthrofibrosis (AF) and femoral rotational mal-alignment in total knee arthroplasty (TKA). We hypothesized an increased internal mal-rotation of the femoral component leading to unphysiological kinematic motion of the arthroplastic knee joint. These repetitive microtrauma may then induce increased synovial hyperplasia leading to arthrofibrosis. Arthrofibrosis is an ill-defined entity that results in unsatisfactory outcome following TKA. Biological and mechanical factors have been suggested as etiology, but specific causes have not been identified.
This study has been cleared by the Ethical Committee, University of Zurich, Switzerland.