Jones DG Vane A Coulter G Herbison P Dunbar J
Full Access

The aim of this study was to determine the inter and intra observer reliability of ultrasound measurements in treated unstable neonatal hips and whether ultrasound measurements correlate with radiological outcome at 6 months.

Sixty-four babies treated from birth with a Pavlik harness for neonatal hip instability were scanned at 2 and 6 weeks. The α and β angles of Graf, the combined (H) angle of Hosny and the femoral head coverage (FHC) were measured by 3 observers and inter-observer and intra-observer repeatability co-efficients calculated using 95% confidence limits. Hips were categorized as normal, abnormal or borderline for each parameter and Kappa values calculated. A stepwise linear regression analysis was performed to assess any relationship between ultrasound measurements at 2 or 6 weeks and outcome as determined by acetabular index at 6 months.

Seven hundred and ninety two sets of measurements were made from 248 scans. The α angle had the smallest interobserver range (17°), the H angle range was 21°and the β angle 28°. Kappa values showed good agreement for FHC and β angle. The mean acetabular index of all hips at 6 months was 26° (sd 4.9). The acetabular index was 30° or greater in 24 hips (18 babies) despite prolonged splintage in 9 hips (6 babies). The FHC at 6 weeks was predictive of acetabular index at 6 months (regression coefficient −0.27, 95% CI −0.42 to −0.12, p< 0.001)

We recommend the FHC as being reproducible, useful and predictive of outcome in neonatal hips treated for instability.