When total ankle arthroplasty (TAA) is performed, although tibial osteotomy is instructed to be perpendicular to long axis of tibia, there is no established index for the talar bone corrective osteotomy. Then, we have been deciding the correction angle at the plan for adjustment of the loading axis through whole lower extremities. We studied 17 TAA cases with rheumatoid arthritis (RA). X-ray picture of hip to calcaneus view (hip joint to tip of the calcaneus) defined to show more approximated loading axis has been referred for the preoperative planning. Furthermore, the data of correction angle has been reflected to pre-designed custom-made surgical guide. If soft tissue balance was not acceptable, malleolar sliding osteotomy was added. The distance between the centre of ankle joint and the axis (preD) was measured (mm) preoperatively, and the distance between the centre of prosthesis and the axis (postD) was measured postoperatively. Next, the tilting angle between tibial and talar components (defined as the index of prosthesis edge loading) were measured with X-rays during standing. Tibio Calcaneal (TC) angle was also measured pre and postoperatively. TC angle was significantly improved from 8.3±6.0° to 3.5±3.6° postoperatively (P=0.028). PreD was 12.9±9.6mm, and that was significantly improved to 4.8±6.3mm (postD) (P=0.006). Within 17 cases, 8 cases showed 0–1mm of postD, 4 cases showed 1–5mm of postD, remaining 5 cases concomitant subtalar fusion with severe valgus and varus hindfoot deformity showed over 8mm of postD. All of the 12 cases showing within 5mm of postD indicated within 13mm of preD. The tilting angle between components was 0.17±0.37° postoperatively. Taken together, pre-designed corrective talar osteotomy based on preoperative planning using hip to calcaneus view was useful to adjust the mechanical axis for replaced ankle joint in RA cases. Furthermore, after surgery, the hip to calcaneus view was useful to evaluate post-operative mechanical axis of whole lower extremities.
Multiaxial rotation of femoral component is generated in a wide range against UHMWPE tibial insert during ambulation or deep bending activities. Simultaneously, microscopic oscillation and twisting might accompany with such a wide-range motion. Such a combined in-vivo kinetics is expected to bring more severe wear to the sliding surface of knee joint prostheses than that in a case of single macro-kinetics (i.e., that commonly reproduced by conventional wear simulators). In order to reproduce clinical surface degradation correctly and quantitatively in simulator tests, we have to consider microscopic motions at the joint bearing surfaces. The purpose of this study is to analyze the influence of the composite knee motion on wear using a non-destructive spectroscopic approach. The crystalline phase in UHMWPE is pre-oriented in the tibial insert from the manufacturing process, but the orientation of crystalline lamellae is sensitive to mechanical loading. Therefore, the orientation of the crystalline lamellae on the surface of retrieved UHMWPE tibial inserts could reflect the local motions in vivo generated in the joint during ambulation. The visualization of (orthorhombic) crystalline lamellae might ultimately lead to the possibility of tracking back the wear history of the joint. In this study, polarized Raman spectroscopy was employed in order to non-destructively visualize the lamellar orientation in UHMWPE tibial inserts, which were retrieved after exposures in human body elapsing several years. According to this Raman analysis and in comparison with an unused insert, the orientation of surface lamellae was found to have been clearly changed due to wear in accordance to the local motion of the femoral component. Additionally, we could obtain information about the origin of delamination from the in-depth profile for lamellae orientation angle. This study not only shows the possibility of optimizing the UHMWPE structure to minimize wear but also gives a hint for the development of knee simulators of the next generation.
Resection arthroplasty has been accepted as the treatment of choice for forefoot deformities in RA patients. Recent advance of drug therapy against RA encouraged us to preserve the joint in correction of forefoot deformities. Our technique aimed at preservation of the function of the MTP joints and is suitable for mild deformities in which only one or two rays are involved. Furthermore it is easy to correct the deformity of spray foot and reduce the plantar prominence of metatarsal head. This study revealed the good clinical result in short term follow-up. Although the long term result must to be waited, this method is one of recommendable options for RA patients with forefoot deformities.