Frequency is probably under evaluated and their treatment and consequences subject to discussion. Dislocation has to be differentiated from knee instability, subluxation and expulsion of the PE tibial insert. The purpose of this review was to study their mechanism, treatment and consequences. A modification of the surgical technique and the insert design was deduced.
A prospective analysis was performed to compare the following variables of these patients (study group) to 56 cases who did not experience that complication (control group): age, sex, weight, component size, surgical approach, importance of release, pre and post surgical scores, alignment, stability, patella and component thickness. Statistical analysis of these parameters was performed.
Conservative treatment was successful in 10 cases, but 3 recurrent dislocations and a neglected dislocation were treated surgically after modification of the tibial insert.
After modifications of the stabilizer concerning height and slight posterior displacement, in a personal series of 129 TKA, dislocations disappeared.