header advert
Results 1 - 3 of 3
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 52 - 52
1 Oct 2022
Müller N Trampuz A Gonzalez-Moreno M
Full Access

Aim

The rise of multidrug-resistant bacteria and the decreasing efficacy of antibiotic therapy in successfully treating biofilm-associated infections are prompting the exploration of alternative treatment options. This study investigates the efficacy of different bioactive glass (BAG) formulations - alone or combined with vancomycin - to eradicate biofilm. Further, we study the influence of BAG on pH and osmotic pressure as important factors limiting bacterial growth.

Method

Different BAG-S53P4 formulations were used for this study, including (a) BAG-powder (<45 μm), (b) BAG-granules (500–800 μm), (c) a cone-shaped BAG-scaffold and (d) two kinds of BAG-putty containing granules, with no powder (putty-A) or with additional powder (putty-B), and a synthetic binder. Inert glass beads were included as control. All formulations were tested in a concentration of 1750 g/ml in Müller-Hinton-Broth. Targeted bacteria included methicillin-resistant Staphylococcus aureus (MRSA) and epidermidis (MRSE). Vancomycin was tested at the minimum-inhibitory-concentration for each strain (1 µg/ml for MRSA; 2 μg/ml for MRSE).

To investigate the antibiofilm effect of BAG alone or combined with vancomycin, 3 hour-old MRSA or MRSE biofilms were formed on porous glass beads and exposed to BAG ± vancomycin for 24h, 72h and 168h. After co-incubation, biofilm-beads were deep-washed in phosphate-buffered saline and placed in glass vials containing fresh medium. Recovering biofilm bacteria were detected by measuring growth-related heat production at 37°C for 24h by isothermal microcalorimetry.

Changes in pH and osmotic pressure over time were assessed after co-incubation of each BAG formulation in Müller-Hinton-Broth for 0h, 24h, 72h and 168h.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 7 - 7
1 Mar 2021
Wang L Tkhilaishvili T Trampuz A Gonzalez-Moreno M
Full Access

Aim

Rifampicin plays an important role in the treatment of staphylococcal prosthetic joint infection, as rifampicin-containing combinations have shown a high efficacy against S. aureus biofilm infections. However, the emergence of rifampin-resistant strains is a feared complication and the use of rifampicin in those cases seems unwarranted. Therefore, we evaluated the activity of bacteriophage Sb1 in combination with different antibiotics against the biofilm of four rifampicin-resistant MRSA strains as alternative therapeutic approach.

Method

Four rifampicin-resistant MRSA strains were used in this study. The MIC for all tested antibiotics was determined by Etest. Biofilms were formed on porous glass beads for 24h and exposed to Sb1 (107 PFU/mL) for 24h followed by exposure to antibiotic for 24h. Viability of bacteria after antimicrobial treatment was detected by beads sonication and plating of the sonication fluids. The minimum biofilm eradication concentration (MBEC) was defined as the lowest concentration of antibiotic required to kill all cells resulting in the appearance of no colony after plating of the sonication fluid (detection limit <20 CFU/mL). The synergistic effects were observed when Sb1 combined with antibiotics used at least 2 log-reduction lower concentrations.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 17 - 17
1 Dec 2019
Wang L Luca MD Tkhilaishvili T Gonzalez-Moreno M Trampuz A
Full Access

Aim

Ciprofloxacin is recommended as anti-biofilm therapy for gram-negative periprosthetic joint infection. With ciprofloxacin monotherapy, resistance in gram-negative bacteria was observed. Therefore, we evaluated in vitro synergistic activity of fosfomycin, ciprofloxacin and gentamicin combinations against biofilms formed by E. coli and P. aeruginosa strains.

Method

E. coli ATCC 25922, P. aeruginosa ATCC 27853 and 15 clinical isolates were used for this study. MIC values were determined by Etest. Biofilms were formed on porous sintered glass beads for 24h and exposed to antibiotics for further 24h. Viability of bacteria on the glass beads after antibiotic treatment was detected by cfu counting of the sonicated beads. The minimum biofilm eradication concentration (MBEC) was defined as the lowest concentration of antibiotic required to kill biofilm cells. Synergistic activity against biofilm was evaluated by calculation of the fractional inhibitory concentration index (FICI).