Objective evaluations of resident performance can be difficult to simulate. A novel competency based surgical OSCE was developed to evaluate surgical skill. The goal of this study was to test the construct validity comparing previously validated Ottawa scores (O-scores) and Orthopaedic in-training evaluation scores (OITE). An OSCE designed to simulate typical general orthopaedic surgical cases was developed to evaluate resident surgical performance. Post-graduate year (PGY) 3–5 trainees have an encounter (interview and physical exam) with a standardized patient and perform a correlating surgery on a cadaver. Examiners evaluate all components of the treatment plan and provide an overall score on the OSCE and also provide an O-score on overall surgical performance. Convergent and divergent validity was assessed comparing OSCE scores to O-scores and OITE scores. SPSS was used for statistical analysis. ANOVA was used to compare PGY averages and Pearson correlation coefficients were calculated to compare OSCE versus O-score and OITE scores. A total of 96 simulated surgical cases were evaluated over a 3 year period for 24 trainees. There was a significant difference in OSCE scores based on year of training. (PGY3 − 6.06/15, PGY4 − 8.16/15 and PGY5 − 11.14/15, p < 0 .001). OSCE and O-scores demonstrated a strong positive correlation of +0.89 while OSCE and OITE scores demonstrated a moderate positive correlation of 0.68. OSCE scores demonstrated strong convergent and moderate divergent correlation. A positive trajectory based on level of training and stronger correlations with established, validated scores supports the construct validity of the novel surgical OSCE.
Glenoid component loosening is a common reason for failed total shoulder arthroplasty. Multiple factors have been suggested as causes for component loosening that may be related to cement technique. The purpose of the study was to compare the load transfer across a polyethylene glenoid bone construct with two different cementing techniques. Eight cadaveric specimens underwent polyethylene glenoid component implantation. Four had cement around the pegs only (CPEG) and four had cement across the entire back (CBACK) of the implant including around the pegs. Step loading was performed with a pneumatic actuator and a non-conforming humeral head construct capable of applying loads at various angles. Strain gauges were placed at the superior and inferior poles of the glenoid and position trackers were applied to the superior and inferior aspects polyethylene component. Micro CT data were obtained before and after the loading protocol.Purpose
Method