The review of the first 325 Exeter Universal hips reported good long term survivorship despite the majority of cups being metal backed. We have reviewed the long term performance of the concentric all-polyethylene Exeter cups used with the Universal Exeter stem. Clinical and radiographic outcomes of 263 consecutive primary hip arthroplasties in 242 patients with mean age 66 years (range, 18 to 89) were reviewed. 118 cases subsequently died none of whom underwent a revision. Eighteen hips have been revised; thirteen for aseptic cup loosening, three for recurrent dislocation and two for deep infection. Three patients (four hips) were lost to follow-up. The minimum follow-up of the remaining 123 hips was 10 years (mean 13.3 years, range 10–17). Radiographs demonstrated 6 (6%) of the remaining acetabular prostheses were loose. The Kaplan Meier survivorship at 14.5 years with endpoint revision for all causes is 91.5% (95% CI 86.6 to 96.2%). With endpoint revision for aseptic cup loosening, survivorship is 93.3% (CI 88.8 to 97.8%). This series included a number of complex cases requiring bone blocks and/or chip autograft for acetabular deficiencies. The concentric all polythene Exeter cup and Exeter stem has excellent long term results particularly when factoring in the complexity of cases in this series.
Retention of well fixed bone cement at the time of a revision THA is an attractive proposition, as its removal can be difficult, time consuming and may result in extensive bone stock loss or fracture. Previously reported poor results of cemented revision THA, however, have tended to discourage Surgeons from performing ‘cement in cement’ revisions, and this technique is not in widespread use. Since 1989 in Exeter, we have performed a ‘cement within cement’ femoral stem revision on 354 occasions. An Exeter polished tapered stem has been cemented into the existing cement mantle on each occasion. Clinical and radiological follow up of 5 years or longer is available for 156 cases. On no occasion has a cement in cement femoral stem had to be re-revised during this time for subsequent aseptic loosening. This has encouraged the refinement of this technique, including the development of a new short stem designed specifically for cement within cement revisions. This stem is designed to fit into an existing well fixed cement mantle of most designs of cemented femoral components or hemi-arthroplasties, with only limited preparation of the proximal mantle required. The new stem greatly simplifies cement in cement revision and minimises the risk of distal shaft perforation or fracture, which is otherwise a potential hazard when reaming out distal cement to accommodate a longer prosthesis.
Acetabular component loosening and pelvic osteolysis continue to be a significant clinical challenge in revision hip arthroplasty. We present results of 339 cases of acetabular reconstruction with impacted allograft. All patients who under went acetabular reconstruction with impaction allograft between July 1995 and July 1999 were included. Clinical and radiographic data was collected prospectively. There were 339 patients identified. Average age was 71 years. The majority were first time revisions (201) but the group includes 2nd, 3rd and 4th revisions with 34 two-stage revisions and 44 primary arthroplasties. There were multiple surgeons with 2/3 being consultants and 1/3 fellows. Pre and post-operative clinical assessment included Oxford and Harris hip scores, and a modified Charnley score for pain, function and range of movement. Pre-operative radiographs were classified with the Paprosky classification. Follow up radiographs were assessed for graft thickness, component migration, graft reabsorption and lucent lines. There were 10 grade I, 205 grade II, and 103 grade III defects with 3 pelvic discontinuities. Reconstruction methods included impaction only, rim and/or medial mesh, KP plate fixation and reinforcement cages. Follow up average was 6.1 years (4.3 – 8.4) and no patient was lost. Infection was identified in 13 patients (5 recurrent 89% eradication and 8 new 2.6%). There were 6 nerve injuries, 2 remain unresolved and 13 patients dislocated (3.8%). There have been 46 deaths in the group with 3 being peri-operative. There have been 18 re-operations for aseptic loosening. 7 KP plates fractured, 1 cage migrated and 10 rim meshes failed. Factors associated with aseptic loosening include use of a large rim mesh particularly with an allograft thickness of >
2cm. We conclude that impaction allografting is a reliable method for acetabular reconstruction. Careful consideration should be given when allograft thickness will be >
2cm and a large rim mesh is required.