header advert
Results 1 - 3 of 3
Results per page:
Bone & Joint Open
Vol. 2, Issue 3 | Pages 163 - 173
1 Mar 2021
Schlösser TPC Garrido E Tsirikos AI McMaster MJ

Aims

High-grade dysplastic spondylolisthesis is a disabling disorder for which many different operative techniques have been described. The aim of this study is to evaluate Scoliosis Research Society 22-item (SRS-22r) scores, global balance, and regional spino-pelvic alignment from two to 25 years after surgery for high-grade dysplastic spondylolisthesis using an all-posterior partial reduction, transfixation technique.

Methods

SRS-22r and full-spine lateral radiographs were collected for the 28 young patients (age 13.4 years (SD 2.6) who underwent surgery for high-grade dysplastic spondylolisthesis in our centre (Scottish National Spinal Deformity Service) between 1995 and 2018. The mean follow-up was nine years (2 to 25), and one patient was lost to follow-up. The standard surgical technique was an all-posterior, partial reduction, and S1 to L5 transfixation screw technique without direct decompression. Parameters for segmental (slip percentage, Dubousset’s lumbosacral angle) and regional alignment (pelvic tilt, sacral slope, L5 incidence, lumbar lordosis, and thoracic kyphosis) and global balance (T1 spino-pelvic inclination) were measured. SRS-22r scores were compared between patients with a balanced and unbalanced pelvis at final follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 12 - 12
1 Jun 2012
Noordeen H Shah S Elsebaie H Garrido E Farooq N Mukhtar M
Full Access

Introduction

Growing rods are used in the treatment of early-onset scoliosis. The aim of this technique is to achieve deformity correction while maintaining spinal growth. Gradual stiffening or spontaneous fusion of the spine can interfere with the ability to lengthen. Furthermore, diminished acquired length with serial distraction is common and needs to be evaluated and quantified. The purpose of this prospective study was to measure the forces and amount of distraction over time in patients with early-onset scoliosis treated with growing rods.

Methods

Distraction forces were measured prospectively during 60 consecutive lengthening procedures in 26 patients. All patients had single submuscular rod constructs with side-to-side connectors. For every measurement, output from a transducer on a dedicated pair of distraction calipers was recorded at zero load status, and the force was then recorded at every 1 mm lengthening; length was obtained at each event and was recorded in millimeters.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XX | Pages 12 - 12
1 May 2012
Altaf F Osei N Garrido E Al-mukhtar M Natali C Sivaraman A Noordeen H
Full Access

We describe the results of a prospective case series to evaluate a technique of direct pars repair stabilised with a construct that consists of a pair of pedicle screws connected with a u-shaped modular link that passes beneath the spinous process. Tightening the link to the screws compresses the bone grafted pars defect providing rigid intrasegmental fixation. 20 patients aged between 9 and 21 years with a pars defect at L5 confirmed on computed tomography (CT) were included. The average age of the patients was 13.9 years. The eligible patient had Grade I or less spondylolisthesis and no evidence of intervertebral degeneration on MRI. The average duration of follow-up was 4 years. Clinical assessments for all patients was via the Oswestry disability index (ODI) and visual analogue scores (VAS). At the latest follow-up, 18 of the 20 patients had excellent clinical outcomes with a significant (p<0.001) improvement in their ODI and VAS scores with a mean post-operative ODI score of 8%. Fusion of the pars defect as assessed by CT showed fusion rates of 80%. There were no hardware complications. The strength of the construct obviates the need for post-operative immobilisation.