Advertisement for orthosearch.org.uk
Results 1 - 19 of 19
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 47 - 47
23 Jun 2023
Garbuz DS
Full Access

The purpose of this study was to determine long-term survival free from all-cause revision and stem-related failure, as well as radiographic and functional outcomes of the ZMR stem in revision THA.

We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR Revision Hip system from the year 2000 to 2007 (minimum two-year follow-up). Of the 112 ZMR hips (110 patients) identified, a total of 106 hips (104 patients) met inclusion criteria. The mean study follow-up 13.9 years (range 2–22). Indications for index ZMR revision included aseptic loosening (72.1%), periprosthetic joint infection (17.3%), periprosthetic fracture (9.6%), and stem fracture (1.0%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. Validated patient reported outcomes were collected and available radiographs were reviewed to determine implant stability.

A total of 17 hips (16.0%) underwent a re-revision of any component. The indications for re-revision were stem failure (35.3%), infection (29.4%), instability (29.4%), and aseptic loosening of the acetabular component (5.9%). The five- and 15-year all-cause survivorship was 89.5% (95% CI 86.5–92.5) and 83.0% (95% CI 79.2–86.8), respectively. There were six re-revisions for stem failure (5.7%); five for stem fracture and one for aseptic loosening. The average time to stem failure was 4.6 years (range 1.3–8.2). The five- and 15-year survivorship free from stem-related failure was 97.2% (95% CI 95.6–98.8) and 93.9% (95% CI 91.5–96.3), respectively. At final follow-up the mean Oxford hip score was 36.9 and all surviving ZMR stems were well fixed on radiographs.

Femoral revision with the ZMR stem offers satisfactory long-term survivorship and promising clinical outcomes. Although uncommon, stem fracture was the most common reason for stem-related failure.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 182 - 187
14 Mar 2023
Sheridan GA Hanlon M Welch-Phillips A Spratt K Hagan R O'Byrne JM Kenny PJ Kurmis AP Masri BA Garbuz DS Hurson CJ

Aims

Hip resurfacing remains a potentially valuable surgical procedure for appropriately-selected patients with optimised implant choices. However, concern regarding high early failure rates continues to undermine confidence in use. A large contributor to failure is adverse local tissue reactions around metal-on-metal (MoM) bearing surfaces. Such phenomena have been well-explored around MoM total hip arthroplasties, but comparable data in equivalent hip resurfacing procedures is lacking. In order to define genetic predisposition, we performed a case-control study investigating the role of human leucocyte antigen (HLA) genotype in the development of pseudotumours around MoM hip resurfacings.

Methods

A matched case-control study was performed using the prospectively-collected database at the host institution. In all, 16 MoM hip resurfacing 'cases' were identified as having symptomatic periprosthetic pseudotumours on preoperative metal artefact reduction sequence (MARS) MRI, and were subsequently histologically confirmed as high-grade aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) at revision surgery. ‘Controls’ were matched by implant type in the absence of evidence of pseudotumour. Blood samples from all cases and controls were collected prospectively for high resolution genetic a nalysis targeting 11 separate HLA loci. Statistical significance was set at 0.10 a priori to determine the association between HLA genotype and pseudotumour formation, given the small sample size.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 5 - 5
1 Oct 2020
Zamora T Garbuz DS Greidanus NV Masri BA
Full Access

Introduction

Our objective is to describe early and midterm results with the use of a new knee prosthesis as an articulating spacer in planned two-stage management for infected total knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a completed 2-stage revision.

Methods

Forty-seven patients (48 knees) from January 2012 and November 2017 underwent a 2-stage exchange with an articulating spacer with new implants was used for a chronic knee periprosthetic joint infection with a mean follow-up of 3.7 years (2–6.5 years).

The most frequently identified infecting organism was MSSA (31%), MRSA (21%) or MRSE (20%). At the first stage, a new PS femoral component and a new all-polyethylene posterior stabilized (PS) tibial component or a standard PS tibial liner were cemented with antibiotic-cement, typically 3.6 gm tobramycin and vancomycin 1.5 gm. IV antibiotics for six weeks were administered. The planned reimplantation was at 3 months, but ninetteen spacers (14 all poly tibias and 5 tibial liner) were retained for over 12 months.

Postoperative assessment included knee range of motion (ROM), quality of life (QOL) scores (SF-12, WOMAC, KOOS, Oxford, and UCLA scores), and a satisfaction scale from 0–100%.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 6 - 6
1 Oct 2019
Masri BA Zamora T Garbuz DS Greidanus NV
Full Access

Introduction

The number of medial unicompartmental knee replacements (UKR) performed for arthritis has increased and as such, revisions to total knee replacement (TKR) is increasing. Previous studies have investigated survivorship of UKR to TKR revision and functional outcomes compared to TKR to TKR revision, but have failed to detail the surgical considerations involved in these revisions. Our objectives are to investigate the detailed surgical considerations involved in UKR to TKR revisions.

Methods

This study is a retrospective comparative analysis of a prospectively collected database. From 2005 to 2017, 61 revisions of UKR to TKR were completed at a single center. Our inclusion criteria included: revision of UKR to TKR or TKR to TKR with minimum 1 year follow-up. Our exclusion criteria include: single component and liner revisions and revision for infection. The 61 UKR to TKR revisions were matched 2:1 with respect to age, ASA and BMI to a group of 122 TKR to TKR revisions. The following data was collected: indication for and time to revision, operative skin to skin surgical time, the use of specialized equipment (augment size/location, stem use), intraoperative and postoperative complications, re-operations and outcome scores (WOMAC, Oxford 12, SF 12, satisfaction score).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 20 - 20
1 Oct 2019
Masri BA Waly F Duncan CP Greidanus NV Garbuz DS
Full Access

Introduction

The practice of overlapping surgery has been increasing in the delivery of orthopaedic care, aiming to provide efficient, high-quality care. However, there have been concerns about the safety of this practice. The purpose of this study is to examine safety and efficacy of a model of partially overlapping surgery that we termed “the swing room” in practice in primary hip and knee arthroplasty.

Methods

A retrospective review of prospectively collected data using an administrative database was carried out on patients who underwent primary unilateral total hip and total knee arthroplasty from 2006 to 2017 at two sites of one academic center staffed by four arthroplasty surgeons. All revisions and bilateral primary procedures were excluded. Cases were stratified as overlapping or non-overlapping. Overlapping was defined when a surgeon had access to two operating rooms with two teams, and non-overlapping was defined as when a surgeon only had access to a single operating room on a particular day. Patient demographic characteristics, operating room time, procedure time, length of stay, Postoperative complications within 30 days of the procedure, unplanned hospital readmissions, unplanned reoperations, and emergency department visits were collected. The Fisher's exact Wilcoxon rank-sum test and logistic regression analysis were used for statistical analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 72 - 72
1 Oct 2018
El-Husseiny M Masri BA Duncan CP Garbuz DS
Full Access

Background

Fully constrained liners are used to treat recurrent dislocations or patients at high risk after total hip replacements. However, they can cause significant morbidities including recurrent dislocations, infections, aseptic loosening and fractures. We examine long term results of 111 patients with tripolar constrained components to assess their redislocation and failure rate.

Questions/purposes

The purpose of this study was to assess survivorship, complications and functional outcomes at a minimum 10 years after the constrained tripolar liners used in our institute.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 73 - 73
1 Oct 2018
El-Husseiny M Masri BA Duncan CP Garbuz DS
Full Access

Background

High complication rates and poor outcomes have been widely reported in patients undergoing revision of large head metal-on-metal arthroplasty. A previous study from our center showed high rates of dislocation, nerve injury, early cup loosening and pseudotumor recurrence. After noting these issues, we implemented the following changes in surgical protocol in all large head MOM revisions: 1. Use of highly porous shells in all cases 2. Use of largest femoral head possible 3. Low threshold for use of dual mobility and constrained liners when abductors affected or absent posterior capsule 4. Use of ceramic head with titanium sleeve in all cases 5. Partial resection of pseudotumor adjacent to sciatic and femoral nerves.

Questions/purposes

The purpose of the present study is to compare the new surgical protocol above to our previously reported early complications in this group of patients

We specifically looked at (1) complications including reoperations; (2) radiologic outcomes; and (3) functional outcomes. Complication rates after (Group 1), and before (Group 2) modified surgical protocol were compared using Chi-square test, assuming statistical significance p<0.05.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 40 - 40
1 Oct 2018
Garbuz DS Kurmis AP Herman A Masri BA
Full Access

Background

Pseudotumor or high grade ALVAL (aseptic lymphocyte-dominated vasculitis-associated lesion) development around total hip replacements secondary to local metal debris generation – especially in the setting of metal-on-metal bearings – is a well-recognised histopathologic phenomenon. Recent work has suggested a strong genetic correlation with an individual's risk of such lesion development following metal exposure. Emerging data have highlighted a similar potential concern around total knee replacements (TKRs), particularly with increasing construct modularity. To date, the body-of-knowledge pertaining to TKR-associated ALVALs has largely been limited to individual case reports or small retrospective case series’, with no large-scale investigation looking at this potential complication. This study sought to establish the preliminary prevalence of pseudotumor or high grade ALVAL formation seen at the revision of primary TKRs and to establish the correlation between histologic ALVAL grade and patient-reported functional outcomes.

Methods

Findings of 1263 consecutive patients undergoing revision knee surgery, at a high-volume referral center, were reviewed. 161 cases of active infection were excluded. Complete histopathology reports were subsequently available for 321 (29.1%) non-infective cases. Each case was independently histologically-classified using a previously validated scoring system reflecting ALVAL grade. Post-operative patient-reported outcomes measures (PROMs) were available for 134 patients (41.7%), allowing direct correlation between functional performance and the established histopathology results.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 109 - 109
1 Sep 2012
Masri BA Williams DH Greidanus NV Duncan CP Garbuz DS
Full Access

Purpose

There is a postulated association between increased serum metal ions and pseudotumour formation in patients with metal-on-metal hip replacements. The primary aim of this study was to assess the prevalence of pseudotumour in 31 asymptomatic patients with a large femoral head (LFH) metal-on-metal hip implant. This was compared to the prevalence of pseudotumour in 20 matched asymptomatic patients with a hip resurfacing (HRA) and 24 matched asymptomatic patients with a standard metal-on-polyethylene (MOP) total hip. A secondary objective was to assess possible correlation between increased serum metal ions and pseudotumour formation

Method

Ultrasound examination of the three groups was performed at a minimum follow up of two years. Serum metal ions were measured in the metal-on-metal LFH and HRA groups at a minimum of two years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 106 - 106
1 Sep 2012
Masri BA Garbuz DS Duncan CP VGreidanus N Bohm E Valle CJD Gross AE
Full Access

Purpose

Dislocation after revision total hip is a common complication. The purpose of this study was to assess whether a large femoral head (36/40mm) would result in a decreased dislocation rate compared to a standard head (32mm).

Method

A randomized clinical trial was undertaken to assess the effect of large femoral heads on dislocation after revision total hip. Patients undergoing revision hip arthroplasty at seven centers were randomized to 32mm head or 36/40mm head. Patients were stratified according to surgeon. Primary endpoint was dislocation. Rates were compared with Fishers exact test. Secondary outcome measures were quality of life: WOMAC, SF-36 and satisfaction. One hundred eighty four patients were randomized: 92 in the 32mm head group and 92 in the large head group. Baseline demographics were similar in the two groups. Patients were followed from two to five years postoperatively


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 96 - 96
1 Sep 2012
Masri BA Baker RP Noordin S Greidanus NV Garbuz DS
Full Access

Purpose

The outcome following isolated liner exchange for revision knee arthroplasty, while an attractive option for its simplicity, has a mixed outcome reported in the literature. We report our experience in patients who had a minimum of two years follow-up.

Method

From our database we identified 44 cases in 41 patients who had an isolated liner exchange for a failed primary knee replacement. Twenty were female and the mean body mass index was 33 (range 20 to 49). The mean time to revision from their index procedure was 76 months (range 8 to 152). The mean age at revision was 69 years (range 45 to 90). Patients were assessed by use of validated quality of life questionnaires: Oxford-12, UCLA Activity Level, WOMAC and SF-12. Patients current scores were compared to pre-operative scores in 19 cases. Radiographs were assessed for polyethylene wear, osteolysis and alignment with respect to the mechanical axis. Intra-operative findings were compared to radiographic findings.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 113 - 113
1 Sep 2012
Greidanus NV Garbuz DS Masri BA Duncan CP Gross AE Tanzer M Aziz A Anis A
Full Access

Purpose

The purpose of this study was to compare and evaluate the cost-effectiveness of the MIS Anterolateral Approach to that of the MIS Posterolateral and MIS Direct Lateral Approach.

Method

A prospective randomized control trial was designed and conducted to compare the MIS Anterolateral Approach to that of the MIS Posterolateral and MIS Direct Lateral Approach. Contemporary methods for economic evaluation were used to ascertain direct and indirect costs (in Canadian dollars) along with clinical effectiveness outcomes (SF6D and Pat5D utility measures). University and hospital ethics was obtained and patients were recruited and consented to participate in the RCT resulting in the assignment of 130 patients MIS hip arthroplasty procedures. Baseline patient demographics, comorbidity, quality of life, and utility were obtained for all patients. In-hospital costing data was obtained including operating room and patient room costs as well as medication, rehab and complications. Post-discharge costs were calculated from direct and indirect costs of medication, rehab, medical costs and complications until one year post-operatively. Clinical effectiveness measures were administered at intervals until one year post-operatively.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 587 - 587
1 Nov 2011
Masri BA Gooding CR Greidanus NV Garbuz DS
Full Access

Purpose: Between 1 and 2% of knee arthroplasties are complicated by infection with its associated patient morbidity. Two stage revision remains the gold standard with the minimum interval considered acceptable between the two stages as 6 weeks, but in some cases can be considerably longer depending on the patients’ clinical response to the first stage and intravenous antibiotics. The interval between the 2 stages is to allow eradication of the causative organism, however, this can result in considerable morbidity for the patient. Patients often have a poor range of movement, instability and considerable discomfort during this time and as a result have poor mobility. Further complications can be encountered at the time of the 2nd stage with considerable scarring of the soft tissues, in part secondary to the lack of mobilisation. Traditionally, spacers which are non-articulating have been used, however, problems of instability, scarring and bone erosion have been reported in the literature. The Prostalac knee spacer constitutes an antibiotic loaded acrylic cement body with a metal on polyethylene surface and enables the patient to undergo rehabilitation in the interval between the 2 stages and may also help maintain soft tissue planes as a result. Previous published results with a mean follow up of 48 months suggest the spacer is just as successful at eradicating infection (91%) as other techniques. The aim of this study is to review 119 patients with a minimum follow up of 5 years.

Method: The Prostalac Knee spacer has 2 components, a femoral and a tibial. Each are made of antibiotic-loaded acrylic cement with a small articulation of metal on polyethylene. The spacers are made from moulds so that a component of a suitable size and thickness could be made. This was a retrospective review of 119 consecutive patients. The inclusion criteria included all patients who had undergone a 2 stage revision with the Prostalac Knee spacer who had more than 5 years of follow up. Patients were assessed using the WOMAC, SF-12, Oxford Knee Score and the Knee Society Score.

Results: Thirteen patients (10.9%) out of a total of 119 had recurrence of infection. This gives an overall rate of control of infection of 89%. Of the 46 patients who completed the outcome score questionnaires with more than 5 years follow up, the mean WOMAC score was 65.9, Oxford Knee score was 61, SF-12 (physical component) was 35.7, SF-12 (mental component) was 54.8.

Conclusion: Although the Prostalac components include polyethylene and metal, they do not seem to have a detrimental impact on the rate of control of infection since our results were similar to those previously reported with other best practice techniques. It is our impression that the Prostalac functional spacer allows earlier pain free mobilisation, allowing the potential for earlier hospital discharge. The savings obtained from earlier hospital discharge greatly outweighing the increased cost of the Prostalac functional spacer system.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 30 - 30
1 Mar 2010
Kim W Garbuz DS Hu Y Duan K Masri BA Rizhi W Duncan CP
Full Access

Purpose: Porous tantalum has been shown to be very effective in achieving bone ingrowth. However, in some circumstances, bone quality or quantity is insufficient to allow adequate bone ingrowth. We hypothesized that the addition of alendronate to porous tantalum would enhance the ability of porous tantalum to achieve bone ingrowth in these challenging situations, such as when a gap exists between the implant and bone. We evaluated the effect of alendronate coated porous tantalum on new bone formation in an animal model incorporating a gap between implant and bone.

Method: Thirty-six cylindrical porous tantalum implants were bilaterally implanted into the distal femur of 18 rabbits for 4 weeks. There were 3 groups of implants inserted; a control group of porous tantalum with no coatings, porous tantalum with micro-porous calcium phosphate coating, and porous tantalum coated with micro-porous calcium phosphate and alendronate. Subcutaneous fluorescent labeling was used to track new bone formation. Bone formation was analyzed by backscattered electron microscopy and fluorescent microscopy on undecalcified samples.

Results: The relative increase in mean volume of gap filling, bone ingrowth and total bone formation was 143% (p< 0.001), 259% (p< 0.001) and 193% (p< 0.001) respectively in the alendronate coated porous tantalum compared with the uncoated porous tantalum controls. The relative increase in the percentage of new bone-implant contact length was increased by 804% on average in the alendronate coated porous tantalum compared with the uncoated tantalum controls.

Conclusion: This study demonstrated the significant enhancement of bone-implant gap filling and bone ingrowth which can be achieved by coating porous tantalum with alendronate. It is proposed that, when faced with the clinical problem of revision joint replacement in the face of bone loss (at the hip, knee or elsewhere), the addition of an alendronate-delivery surface coating would enhance biological fixation of the implant and promote the healing of bone defects.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 541 - 541
1 Aug 2008
Kim WY Hu Y Duan K Wang R Garbuz DS Masri BA Duncan CP
Full Access

Introduction: Achieving durable implant–host bone fixation is the major challenge in uncemented revision hip arthroplasty when significant bone stock deficiencies are encountered. The purpose of this study was 1) to develop an experimental model which would simulate the clinical revision hip scenario and 2) determine the effects of alendronate coating on porous tantalum on gap filling and bone ingrowth in the experimental model.

Methods: Thirty-six porous tantalum plugs were implanted into the distal femur, bilaterally of 18 rabbits for four weeks. There were 3 groups of plugs inserted; control groups of porous tantalum plugs (Ta) with no coating, a 2nd control group of porous tantalum plugs with micro-porous calcium phosphate coating, (Ta-CaP) and porous tantalum plugs coated with alendronate (Ta-CaP-ALN). Subcutaneous fluorochrome labelling was used to track new bone formation. Bone formation was analysed by backscattered electron microscopy and fluorescence microscopy on undecalcified histological sections.

Results: The relative increase in mean volume of gap filling, bone ingrowth and total bone formation was 124 %, 232 % and 170 % respectively in Ta-CaP-ALN compared with the uncoated porous tantalum (Ta) controls, which was statistically significant. The contact length of new bone formation on porous tantalum implants in Ta-CaP-ALN was increased by 700% (8-fold) on average compared with the uncoated porous tantalum (Ta) controls.

Discussion: Alendronate coated porous tantalum significantly modulated implant bioactivity compared with controls. This study has demonstrated the significant enhancement of bone-implant gap filling and bone ingrowth, which can be achieved by coating porous tantalum with alendronate. It is proposed that, when faced with the clinical problem of revision joint replacement in the face of bone loss, the addition of alendronate as a surface coating would enhance biological fixation of the implant and promote the healing of bone defects.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 535 - 535
1 Aug 2008
Kim WY Greidanus NV Masri BA Duncan CP Garbuz DS
Full Access

Revision of a failed acetabular reconstruction in total hip arthroplasty (THA) can be challenging when associated with significant bone loss. In cementless revision THA, achieving initial implant stability and maximising host bone contact is key to the success of reconstruction. Porous tantalum acetabular shells may represent an improvement from conventional porous coated uncemented cups in revision acetabular reconstruction associated with severe acetabular bone defects.

Methods: We reviewed the clinical and radiographic results of 46 acetabular revisions with Paprosky 2 and 3 acetabular bone defects done with a hemispheric, tantalum acetabular shell (Trabecular Metal Revision Shell, Zimmer, Warsaw, USA) and multiple supplementary screws for fixation.

Results: At a mean follow-up of 40 (24–51) months, one acetabular shell had been revised in a patient with a Paprosky 3B defect. Two liner revisions were performed for recurrent instability, without porous tantalum shell revision. The clinical outcome showed significant postoperative improvement in all measured sub-scales, compared with baseline pre-operative scores (mean improvement in Oxford Hip Score of 40.0, p < 0.001, in WOMAC of 36.7, p < 0.001, Physical component SF-12 of 12.3, p =0.0003, mental component of SF-12 of 6.8, p = 0.006). Radiographic evidence of osseointegration using validated criteria (Moore’s criteria) was demonstrated in 39 of the 40 hips available for radiographic analysis at a mean of 30.9 months, by two independent observers. Of the remaining six hips, five hips were lost to follow-up and one radiograph demonstrated failure of the hip reconstruction secondary to loss of fixation and superior migration of the component.

Discussion: Cementless acetabular revision with the porous tantalum acetabular shell demonstrated excellent early clinical and radiographic results in a series of complex revision acetabular reconstruction associated with severe bone defects. The evidence of radiographic osseointegration suggests that outcome should remain favourable, however, further longer-term evaluation is warranted.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 534 - 534
1 Aug 2008
Biring GS Kostamo T Masri BA Garbuz DS Duncan CP
Full Access

Introduction: Deep infection in total hip replacement can be devastating. We report the outcomes 10–15 years after two stage revision for hip infection in 103 patients using the PROSTALAC (prosthesis of antibiotic-loaded acrylic cement) hip.

Methods: All patients or their next of kin were contacted to determine their current functional status and whether they had required repeat surgery or had recurrent infection. The Oxford-12, SF-12, and WOMAC questionnaires were administered. A comprehensive chart review was undertaken to review the infective organisms, surgery, approach, complications, and need for further revision surgery.

Results: 11 patients had re-infection, 7 of whom responded to repeat surgery with no further sequelae. Two patients required resection arthroplasty, one patient underwent hip disarticulation after eventual failure of treatment and bone loss, and one immuno-compromised patient developed osteomyelitis and was subsequently lost to follow-up. Long-term success rate for two stage-revision is thus 89%, or 96% with additional surgery. Since then, 3 patients required revisions for aseptic loosening, 1 for recurrent dislocation. We were able to follow up 45 patients, 75 % of whom provided health-related quality of life outcome scores. 39 patients were deceased, with their outcome confirmed via their last follow-up or with family members, for a total follow-up rate of 85 %. 15 patients were lost to follow-up, but did not undergo further surgery or have reinfections treated at our centre.

Discussion: Two-stage revision for hip infection, which includes an interim prosthesis of antibiotic loaded cement, offers a predictable and lasting solution for patients with this difficult problem.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 535 - 535
1 Aug 2008
Biring GS Masri BA Greidanus NV Duncan CP Garbuz DS
Full Access

Introduction: The aims of this study were to

determine predictors of pain, function and activity level 1–2 years after revision hip arthroplasty and

define quality of life outcomes after revision total hip replacement.

Methods: A prospective cohort of 222 patients who underwent revision hip arthroplasty were evaluated. Predictive models were developed and proportional odds regression analyses were performed to identify factors that predict quality of life outcomes at 1 and 2 years post surgery. The dependent outcome variables were WOMAC function, pain and UCLA activity. The independent variables included patient demographic, surgery specific and objective parameters including baseline Western Ontario McMaster Universities (WOMAC) osteoarthritis index, and the Short Form-12 mental component. The Loess method was used to plot the change of WOMAC and SF-12 scores over time.

Results: There was a significant improvement (p< 0.001) in all patient quality of life scores from baseline with results plateauing at 1 year. UCLA activity remained static between 1 and 2 years. In the predictive model, higher baseline WOMAC function (p < 0.001), age between 60–70 (p< 0.037), male gender (0.017), lower Charnley class (p < 0.001) and diagnosis of aseptic loosening (p < 0.003) were significant predictors of improved function.

When considering WOMAC pain as an outcome variable, factors predictive of improving category outcome included baseline WOMAC function (p= 0.001), age between 60–70 (p< 0.004), male gender (p= 0.005), lower Charnley class (p< 0.001) and no previous revisions (p < 0.023). Baseline WOMAC pain did not predict final pain outcome. Baseline WOMAC function (p=0.001), the indication for the operation (p=0.007), and the operating surgeon were significant predictors of UCLA activity at follow up. Peri or post-operative complications were not an adverse predictor of physical function, pain or activity.

Conclusions: Predictors of quality of life outcomes after revision hip replacement-showed that although some patient specific and surgical specific variables were important, age, gender, Charnley class and baseline WOMAC function had the most robust associations with outcomes.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 546 - 546
1 Aug 2008
Biring GS Masri BA Garbuz DS Greidanus NV Duncan CP
Full Access

Introduction: This single incision, anterolateral intermuscular approach (AL-IM) utilizes the interval between gluteus medius and tensor fascia lata. The aims of the study were to compare the quality of life, satisfaction and complications of this approach with two of the most commonly used limited incision transmuscular (TM) approaches, namely the mini-posterior (P-TM) and the mini-direct lateral (L-TM).

Methods: 199 patients receiving MIS THA surgical procedures were evaluated prospectively (63 AL-IM, 68 P-TM and 68 L-TM). The outcome variables were WOMAC function, pain, stiffness, SF-12 (physical & mental), Oxford-12, satisfaction and radiological outcome. Parametric and non-parametric analyses were performed.

Results: There were no significant differences between groups in baseline characteristics including age, sex, BMI, co-morbidity, or pre-op WOMAC, SF-12, Oxford-12 (p> .05). However, the AL-IM group was associated with superior outcomes (p< .05) in WOMAC function, WOMAC pain, global WOMAC, Oxford-12 and SF-12 physical component.

Conclusion: In the short term the AL-IM approach provides significant improvements in quality of life scores over other limited incision approaches. It provides minimal soft tissue disruption and maintains the abductor musculature and posterior soft tissue envelope, with similar complications and radiological outcomes.