We aimed to audit the results of one stop fragility fracture risk assessment service at fracture clinic for non-hip fractures in 50–75 years old patients at Newcastle General Hospital. Currently, fewer than 30% of patients with fragility fractures benefit from secondary prevention in the form of comprehensive risk assessment and bone protection because of multifactorial reasons. We have a fragility fracture risk assessment service staffed by an Osteoporosis Specialist Nurse equipped with a DEXA scanner located at the fracture clinic itself. We carried out a retrospective audit of 349 patients of 50–75 years with suspected non-hip fractures referred from A&
E Department from October 2006 to September 2007. Patients over 75 years were excluded because as per NICE guidelines, they should receive bone protection without need of a DEXA scan. Out of these 349 patients with suspected fractures, 171 had fragility fractures. Median age was 64 years. 69 patients had humerus fracture, 65 had forearm fracture and 23 patients had ankle fracture and 14 had metatarsal fractures. Fracture risk assessment was carried out in 120 (70%) patients. Thirty Seven (31%) patients had osteoporosis and bone protection was recommended to GP. 38 (32%) had osteopenia and lifestyle advice was provided. 45 (37%) had normal axial bone densitometry. 90% patients had DEXA scan at the same time of fracture clinic appointment. Patients with male gender, undisplaced fracture and fewer fracture clinic appointments were more likely to miss fracture risk assessment. Our experience suggests that locating fragility fracture risk assessment service co-ordinated by an Osteoporosis Specialist Nurse at fracture clinic is an efficient way of providing secondary prevention for patients with fragility fractures. This can improve team communication, eliminate delay and improve patient compliance because of ‘One Stop Shop’ service at the time of fracture clinic appointment.
normal subjects with no known structural abnormalities in spine or pelvis. no previous spine operations. Subjects with acute back pain and those who could not tolerate range of motion measurements were excluded. Accurate measurement of lumbar spine flexion is possible using a machine made by a Finnish company called Data Based Care (DBC). The machines accurately measure ranges of spine movement by isolating the movement being measured and immobilising any other muscle groups which may interfere with the movement being measured. We measured lumbar spine flexion as described by Mc Rae et al ie. The modified Schobers test and isolated lumbar spine flexion using the DBC machine. Two researchers were involved in measuring subjects. One set the subject on the DBC machine and took the measurement, whilst the other assessed when the pelvis began to tilt. Thus only isolated forward lumbar flexion was measured. DBC measurements were carried out in a standardised way. The results were then tabulated and correlated.
This study aimed to determine the prevalence of osteoporosis in patients awaiting hip and knee replacement for osteoarthritis and to review them two years later to determine the changes in bone density following joint replacement. Patients aged between 65 and 80 years awaiting total hip or knee replacement were invited to participate. Lumbar spine, bilateral femoral and forearm bone mineral density (BMD) measurements were obtained using dual energy x-ray absorptiometry. BMD values were standardised using previously published T-scores and Z-scores. To assess clinical status, patients completed a questionnaire including the Western Ontario and McMaster University OA Index (WOMAC). All measurements were repeated at two-years. Participants included 199 patients (84 hips and 115 knees) with a mean age of 72 years (SD 4.0) and were predominantly female (hips 67%, knees 50%). At baseline 46/199 (23%) patients (39 females) had evidence of osteoporosis (WHO definition) at one or more sites with the highest prevalence at the forearm (14%). At two-years 144 patients attended for review with 128 having undergone hip (56) or knee (72) replacement. At this review 39/144 (27%) patients (33 females) had evidence of osteoporosis at one or more sites with the highest prevalence at the forearm (22%). The greatest bone loss occurred at the forearm with median BMD change of minus 4% for females (25th percentile minus 7.3%, 75th percentile minus 1.9%) and minus 2.9% for males (25th percentile minus 4.6%, 75th percentile minus 1.1%). There was a significant difference in WOMAC Pain scores at follow-up between the osteo-porotic and non-osteoporotic knee patients (67 versus 81, p=0.002) indicating that osteoporotic patients had greater knee pain. We have identified the forearm as not only the site with the highest prevalence of osteoporosis but also the greatest bone loss at follow-up. Further evaluation of forearm bone density measurements in the preopera-tive assessment and follow-up of patients awaiting joint replacement for hip and knee OA is required. Larger studies are needed to confirm our finding that the presence of osteoporosis is predictive of worse patient-reported outcomes of knee replacement.