Vol. 94-B, Issue SUPP_XXXVIII | Pages 162 - 162
1 Sep 2012
Bernstein M Desy NM Huk OL Zukor DJ Petit A Antoniou J
Full Access

Purpose

Metal-on-metal (MoM) articulations in total hip replacement (THR) have become an attractive option for young, active patients. Short-term reports have demonstrated elevated systemic metal ion levels in the blood and urine. Disseminated concentrations of cobalt and chromium have raised concern regarding cellular toxicity, chromosomal damage and adverse local soft tissue reactions.

Long-term studies are required to support the increased use of MoM bearings in younger patients given their potential deleterious effects. The purpose of the current study was to report the seven to 13 year clinical, radiographic, and metal ion results in patients following MoM THR.

Method

We prospectively followed 165 patients (196 hips) after second-generation MoM THR between July 1997 and November 2003. Functional outcome was measured using the Harris Hip Score (HHS) and the University of California Los Angeles (UCLA) Activity Score. Radiographic analysis was performed using Einzel-Bild-Roentgen-Analyse (EBRA) by two of the authors blinded to the study. Cobalt and chromium metal ions were measured from whole blood and analyzed using inductively coupled plasma-mass spectrometry as previously described.