Autologous osteochondral grafting has demonstrated positive outcomes for treating articular cartilage defects by replacing the damaged region with a cylindrical graft consisting of bone with a layer of cartilage, taken from a non-loadbearing region of the knee. Despite positive clinical use, factors that cause graft subsidence or poor integration are relatively unknown. The aim of this study was to develop finite element (FE) models of osteochondral grafts within a tibiofemoral joint and to investigate parameters affecting osteochondral graft stability. Initial experimental tests on cadaveric femurs were performed to calibrate the bone properties and graft-bone frictional forces for use in corresponding FE models, generated from µCT scan data. The effects of cartilage defects and osteochondral graft repair were measured by examining contact pressure changes using in vitro tests on a single cadaveric human tibiofemoral joint. Six defects were created in the femoral condyles which were subsequently treated with osteochondral autografts or metal pins. Matching µCT scan-based FE models were created, and the contact patches were compared. Sensitivity to graft bone properties was investigated. The bone material properties and graft-bone frictional forces were successfully calibrated from the initial tests with good resulting levels of agreement (CCC=0.87). The tibiofemoral joint experiment provided a range of cases to model. These cases were well captured experimentally and represented accurately in the FE models. Graft properties relative to host bone had large effects on immediate graft stability despite limited changes to resultant cartilage contact pressure. Model confidence was built through extensive validation and sensitivity testing, and demonstrated that specimen-specific properties were required to accurately represent graft behaviour. The results indicate that graft bone properties affect the immediate stability, which is important for the selection of allografts and design of future synthetic grafts. Supported by the EPSRC-EP/P001076.Acknowledgements
Osteoarthritis (OA) is one of the lead causes of pain and disability in adults. Bone marrow lesions (BMLs) are one feature of subchondral bone involvement in OA. MRI images suggest changes in tissue content and properties in the affected regions however, it is not known if this alters the mechanical behavior of the bone, which could in turn affect OA progression. The aim of this study was to characterize the mechanical properties of BMLs, using a combined experimental and computational approach. Six human cadaveric patellae from donors aged 56–76 were used in this study; all exhibited BML regions under MRI. Bone plugs were taken from non-BML (n = 6) and BML (n = 7) regions within the patellae, with guidance from the MRI. The plugs were imaged at 82µm resolution using micro computed tomography (µCT) and tested under uniaxial compression. Finite element (FE) models were created for each plug from the µCT scans and morphological properties such as bone volume fraction (BV/TV) were also determined. The relationship between bone volume fraction and apparent modulus was investigated for both sample groups.Abstract
Introduction
Methods
Osteoarthritis (OA) affects more than four million people in the UK alone. Bone marrow lesions (BMLs) are a common feature of subchondral bone pathology in OA. Both bone volume fraction and mineral density within the BML are abnormal. The aim of this study was to investigate the effect of a potential treatment (bone augmentation) for BMLs on the knee joint mechanics in cases with healthy and fully degenerated cartilage, using finite element (FE) models of the joint to study the effect of BML size. FE models of a human tibiofemoral joint were created based on models from the Open Knee project (simtk.org). Following initial mesh convergence studies, each model was manipulated in ScanIP (Synopsys-Simpleware, UK) to incorporate a BML 2mm below the surface of the tibial contact region. Models representing extreme cases (healthy cartilage, no cartilage; BML region as an empty cavity or filled with bone substitution material (200GPa)) were generated, each with different sizes of BML. Models were tested under a representative physiological load of 2kN.Abstract
Introduction
Methods
There were 98 tumours treated. In females, the most common tumours were breast (8) and renal (4) and in males, prostate (13), multiple myeloma (12) and lung (10). The thoracic spine was involved in 62, the lumbar in 18, cervical in 16 and sacral in 2. The vertebral body was involved in 76. There were 109 operations. An instrumented fusion was performed in 82. Surgical approach was anterior in 17 (9 cervical, 8 thoracic) and posterior in 80 (5 cervical, 56 thoracic and 17 lumbar). Six patients had combined approaches (2 cervical, 3 thoracic and 1 lumbar). Two patients were treated for metachronous tumours. One patient had non-contiguous metastases treated separately. One patient was treated for local recurrence. One patient had revision for implant failure (anterior thoracic). One patient was explored after deterioration due to loss of autoregulation. Thoraco-abdominal approaches (12) were associated with ileus (2) and pneumonia (3). Of four cases with deep wound infections, three had received prior local irradiation. Two patients died of pulmonary embolus. 83 patients survived beyond three months. All patients demonstrated improvement in pain status. Thirteen of 29 non-ambulatory cases were able to mobilise postoperatively. There were 32 whose Frankel grades improved. Seventeen of these returned to normal (15 from Grade 4 and 2 from Grade 3). One patient with complete motor and sensory loss improved to useful but subnormal status, three others improved to residual motor function. 11 other patients improved one grade. Of those whose scores did not change (76), 53 remained normal, eight maintained useful but subnormal status, five were stabilised with residual motor function, three kept some sensory perception and two had complete motor and sensory loss. One patient deteriorated from residual motor function to complete motor loss. The outcome for sphincter dysfunction (8) was not clear from the notes. In no case was a specific change in function documented.