1 Jul 2023
Mitchell PD Abraham A Carpenter C Henman PD Mavrotas J McCaul J Sanghrajka A Theologis T

Aims

The aim of this study was to determine the consensus best practice approach for the investigation and management of children (aged 0 to 15 years) in the UK with musculoskeletal infection (including septic arthritis, osteomyelitis, pyomyositis, tenosynovitis, fasciitis, and discitis). This consensus can then be used to ensure consistent, safe care for children in UK hospitals and those elsewhere with similar healthcare systems.

Methods

A Delphi approach was used to determine consensus in three core aspects of care: 1) assessment, investigation, and diagnosis; 2) treatment; and 3) service, pathways, and networks. A steering group of paediatric orthopaedic surgeons created statements which were then evaluated through a two-round Delphi survey sent to all members of the British Society for Children’s Orthopaedic Surgery (BSCOS). Statements were only included (‘consensus in’) in the final agreed consensus if at least 75% of respondents scored the statement as critical for inclusion. Statements were discarded (‘consensus out’) if at least 75% of respondents scored them as not important for inclusion. Reporting these results followed the Appraisal Guidelines for Research and Evaluation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 7 - 7
3 Mar 2023
Hughes I May J Carpenter C
Full Access

Introduction

Chronic recurrent multifocal osteomyelitis (CRMO) is a rare condition characterised by bony pain and swelling which may be initially mistaken for bacterial osteomyelitis. The episodic course of the disease may confound the diagnosis and potentially be mistaken for a partial response to antimicrobial therapy. It is an orphan disease and consequently results in many unclear aspects of diagnosis, treatment and follow up for patients. The aim of this study is to evaluate a national tertiary centre's experience with the clinical condition and present one of the largest cohorts to date, emphasizing the vast array of clinical spectrum, course and response to treatment.

Methods

We retrospectively evaluated all children identified with CRMO from the period 2000–2022 within Wales. Demographic data and clinical parameters were selectively identified through the utilisation of a national clinical platform (Welsh Clinical Portal). The diagnosis was based on clinical findings, radiological images, histopathological and microbiological studies


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 5 - 5
3 Mar 2023
Poacher A Ramage G Froud J Carpenter C
Full Access

Introduction

There is little evidence surrounding the clinical implications of a diagnosis of IIa hip dysplasia with no consensus as to its efficacy as a predictor pathological dysplasia or treatment. Therefore, we evaluated the importance of categorising 2a hip dysplasia in to 2a- and 2a+ to better understand the clinical outcomes of each.

Methods

A 9-year retrospective cohort study of patients with a diagnosis of type IIa hip dysplasia between 2011 – 2020 (n=341) in our centre. Ultrasound scans were graded using Graf's classification, assessment of management and DDH progression was completed through prospective data collection by the authors.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_3 | Pages 1 - 1
1 Mar 2022
Wise H McMillian L Carpenter C Mohanty K Abdul W Hughes A
Full Access

Introduction

Current undergraduate trauma and life-support training inadequately equips medical students with the knowledge, practical skills and confidence to manage trauma patients. Often first to the scene of medical emergencies, it is imperative junior doctors feel confident and competent from day one. No UK university currently includes advanced trauma and life support (ATLS) in their curriculum. This study piloted an ATLS course for Cardiff final-year medical students to improve confidence and knowledge in management of the trauma patient.

Aim

To assess the immediate effect of a one-day undergraduate ATLS course on medical student's confidence in management of the trauma patients.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 9 - 9
1 Dec 2014
Aranganathan S Carpenter C Thomas D Hemmadi S O'Doherty D
Full Access

Complex congenital foot deformities pose a challenge to the surgeon due to poor results after extensive surgery. We report the clinical outcomes of children with complex congenital foot deformities treated with UMEX® (Universal mini-external fixator System) frames.

This is a prospective review of our experience in patients treated in this way, from 2004 to 2011. The indications for treatment included resistant/recurrent Congenital Talipes Equino Varus (CTEV), cavo-varus deformity secondary to Charcot-Marie-Tooth disease, arthrogryposis, fibular hemimelia and other congenital abnormalities. A total of 32 children (35 feet) have been treated, out of which 22 were male and 10 were female patients. Age at surgery ranged from 3 to 15 years (median age – 7 years). Three patients underwent bilateral procedures; the reminder (29 patients) underwent unilateral foot operations. Twenty-eight patients had undergone previous surgery including soft-tissue and/or bony corrective procedures.

The frames were removed at an average of 69 days after application, and the patients spent a further 6 weeks in a walking cast. Good functional outcomes were noted in 26 patients in the first postoperative year and in 19 patients in the fifth postoperative year. Further operations were needed in 10 patients. Complications occurred in 10 patients, predominantly pin-site infections and 1 case of bony overgrowth at pin-site and 1 of proximal tibio-fibular diastasis.

This is a simple fixator to use with a short learning curve. In groups of patients with complex congenital abnormalities, we achieved good functional outcome with low-complication rates.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 12 - 12
1 Mar 2014
Carpenter C Filer J Crosskey G Mitchell S
Full Access

Total hip replacement (THR) is NICE recommended for a group of patients with neck of femur fracture (NOF) and guidance published in 2011. In our institution a Hip Fracture Program was established at this time to improve patient care.

An audit of the Hip Fracture Program, appropriateness of THR and management following THR was undertaken and compared to NICE standards, set at 100%, and National Hip Fracture Database (NHFD) results

The case-notes for 53 patients (38 female, 15 male) undergoing THR for NOF between 2011 and 2013 were reviewed: median age 70 yrs (34–87), follow-up 28 months (3–57).

All patients were initiated on a Hip Fracture Program. 92% were eligible for THR according to NICE guidance. Pre-operative pain management (67%), hourly assessment of pain in ED (4%), surgery with 48 hours (32%), pre-operative orthogeriatric review (58%) and intra-operative nerve block (38%) are areas for development, but most results are comparable to NHFD. Post-operative care is satisfactory with daily mobilisation (87%) and post-operative pain management (100%). No post-operative dislocation or infection was recorded. There was one case of post-operative DVT.

This study highlights areas for improvement in hip fracture management and emphasises the benefits in implementing a Hip Fracture Program in this vulnerable patient population.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 16 - 16
1 Feb 2013
Aranganathan S Carpenter C Thomas D Hemmadi S O'Doherty D
Full Access

We report the clinical outcomes of children with complex congenital foot deformities treated with UMEX® mini-external fixators. This is a prospective review of our experience in patients treated in this way, from 2004. The indications for treatment were resistant/recurrent Congenital Talus Equina Varus(CTEV), cavo-varus deformity secondary to Charcot-Marie-Tooth disease, arthrogryposis, fibular hemimelia and other congenital abnormalities. In addition, one patient underwent this treatment since he was allergic to casting material.

A total of 32 children (35 feet) have been treated, with a male to female ratio of 22:10 respectively. The patient-age at operation ranged between 3 and 15 years (median age −7 years). Three patients underwent bilateral procedures and 29 patients underwent unilateral foot operations. Twenty-eight patients underwent previous soft-tissue and bony corrective operations with serial casting. The frames were removed at an average of 69 days after application with a further 6 weeks in a walking cast. Seventy-nine percent of the patients had good functional outcome. Further operations were needed in 10 patients. Complications occurred in 10 patients, including pin-site infections, bony overgrowth at pin-site and proximal tibio-fibular diastasis.

In conclusion, this is a simple fixator to use with a small learning curve. In groups of patients with complex congenital abnormalities, we achieved good functional outcome with low-complication rates.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_11 | Pages 2 - 2
1 Feb 2013
Quick T Carpenter C Gibbons P Little D Skowno J
Full Access

Aim

Vascular compromise following supracondylar fractures is frequently described. Near Infra-red Spectrometry (NIRS) is a technique through which real-time data can be gathered non-invasively on the oxygenation status of tissues. The drive now is to gain knowledge on how NIRS data can be interpreted and to validate its use in the clinical setting.

Methods

This ethically approved prospective study looks at volar forearm compartment oxygen saturation (StO2) in 20 patients with supracondylar fractures requiring operative intervention. Both the injured limb and the contra-lateral, uninjured limb were monitored. 20 patients from a cohort of 29 had full data sets and are thus presented.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 142 - 142
1 Apr 2012
Dhir J Carpenter C Pande R Pyrovolou N Ahuja S
Full Access

We do know that the use of stand-alone cage with no plate is prone to subsidence and segmental kyphosis. Cage and plate construct are prone to adjacent level ossification. Zero P (Synthes, UK) cage combines the functionality of spacer and anterior plate.

Radiological evaluation of subsidence of cervical spine after anterior cervical interbody fusion using Zero P cage system.

Method: Retrospective review of radiographic records of patients undergoing surgery between June 2008- Oct 2009. We evaluated lateral cervical standing radiographs before, after, 6 weeks, 3, 6 months of surgery. We measured subsidence (using Total Intervertebral Height (TIH). All measurements were done using Web 1000 (Impax Agfa). Two level was treated as single segment. Subsidence > 3mm was considered significant.

20 patients (11 male: 9 female) with median age of 51 yrs (40-65) underwent one (n=10) or two level (n= 10) cervical fusion. Immediately post-op there was increase in TIH in one and two level group by 1.74mm (1.61 and 4.25mm (1.48 respectively, which at 6 months reduced to 1.05mm (0.24 (p< 0.003) and 1.32mm (1.29 (p< 0.085) at 6 months respectively. Subsidence was seen in all cases and was rapid in first 3 months and then tailed off. It was significant (> 3mm) only in 2/20 (2%) patients at 6 months.

Early results indicate that spine alignment is maintained radiologically with no associated complications as screw loosening, cage extrusion etc.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 214 - 214
1 May 2009
Lakdawala A Mauffery C Carpenter C Clegg J
Full Access

Introduction: Despite worldwide vaccination programmes Polio is still endemic in some developing countries. Numerous new cases of polio are seen every year in India resulting in significant childhood deformity. The Rotary Club funds voluntary camps aimed at correcting deformities in children. I was part of the surgical team in Jan 2007 led by Mr. J. Clegg.

Clinical experience: Some 141 procedures were carried out in 3 days, 99 by SPR’s under senior supervision. The most frequent procedure was a supra-condylar femoral osteotomy, followed by hip and knee soft tissue releases. For more complex operations we assisted or observed. Some deformity corrections were for non-polio cases. Interesting cases in the OPD included skeletal dysplasias, rickets and congenital deformities.

Conclusion: At the time where MMC restricts overseas training opportunities, I believe this type of mini-fellowship provides valuable experience. Training programmes should have such opportunities available to all trainees.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 521 - 521
1 Aug 2008
Carpenter C Brewster M Mason P Hemmadi S O’Doherty D Clegg J
Full Access

Purpose of study: The UMEX frame was developed from the Joshi external fixator, being first used in the UK in 2004. It corrects deformity by gradual distraction and manipulation. We report the outcomes of a two centre combined experience of the UMEX frame for the treatment of complex congenital foot deformities.

Method: The frame was used in the management of 27 complex foot disorders, the majority of which were resistant club feet. All patients had at least 18 month follow up.

Results: Good deformity correction was achieved in all cases, with a plantigrade foot immediately post-treatment. However, minor degrees of relapse have been noted when the strict postoperative regimen was not followed.

Conclusions: The application of external fixators for the correction of foot deformities can be a complex procedure for the surgeon, and cumbersome for the patient. This frame is simple to apply and manage and allows multi-planar deformity correction in one stage. Our experience and patient outcome data suggest that this technique is a useful surgical option for the Paediatric Orthopaedic surgeon dealing with a relapsed club foot and other complex foot deformities.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 372 - 372
1 Sep 2005
Carpenter C Thomas D Hemmadi S O’Doberty D
Full Access

We report our initial experience with the Universal Mini External Fixator (UMEX) frame for the treatment of complex congenital foot deformities. This new frame is simple to apply and manage. It provides for multiplanar deformity correction in one stage.

The application of external fixators for the correction of foot deformities can be a complex procedure for the surgeon and cumbersome for the patient. Currently, five patients (mean age 10 years, range 4–18) have undergone application of this frame and have completed treatment. We illustrate the ease of its application, potential complications and the early clinical outcomes.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 81 - 81
1 Jan 2004
Maury AC Roy WS Lewis J Carpenter C Brown R Davies J
Full Access

Introduction: Hip fractures are usually evident on plain radiographs. Some are not obvious and require further investigation. A review of the pertinent literature reveals different treatment algorithms for such patients but MRI is recommended as the investigation of choice. Little is stated about the clinical findings in patients with an occult fracture of the hip.

Aims: To investigate any correlation between clinical findings and the presence of fracture on MRI in occult fracture of the hip and use this as a means of speeding the diagnosis of such patients.

Methods: We report a prospective, multi-centre trial. 22 patients admitted with a suspected occult fracture of the hip were assessed clinically for evidence of resting deformity, ecchymosis, point tenderness, hip pain on heel percussion or pistoning and ability to straight leg raise (SLR). The same features were assessed in the contralateral limb. All patients were alert and orientated as to comply with examination. Plain radiograph and MRI findings of both hips were recorded in each case.

Results: Of 22 patients, 17 were unable to perform SLR on the affected side, 5 were able to do so. Of the 18 patients, all had a fracture of either the acetabulum or proximal femur on MRI. Of the group of 5, 2 had normal MRI scans, 1 had a pubic ramus fracture, 1 had bone marrow oedema secondary to osteoarthritis and 1 patient had a six week old valgus impaction fracture. All patients could SLR and had normal MRI of the contralateral hip.

Conclusions: Under the conditions of this study straight leg raise test is 95% sensitive and 95% specific for predicting the presence of fracture in either the acetabulum or proximal femur. We recommend that this simple test can be used to help speed up the diagnosis of and further management of occult fractures of the hip