Historical studies have reported incidences of taper corrosion in retrieved MoP hips of 20–50%. These studies relied on visual assessments, rather than using modern analytical techniques. The Northern Retrieval Registry was initiated to routinely analyse all retrieved hips. The volumetric wear rates of retrieved Exeter head tapers were measured using a coordinate measuring machine using validated methods and compared to the available results obtained from an ongoing study of failed MoM prostheses. Power analysis suggested that we would need at least fifty Exeter head tapers to provide significant results. Non-parametric tests were used to assess differences. We have previously identified head diameter/offset/taper angle and taper surface roughness as variables associated with taper wear. The effect of bearing material combination remains unquantified. These design variables were entered into a multiple regression model following log normalisation of taper wear.Introduction
Patients/Materials and Methods
Although classic teaching holds that the least amount of constraint should be implanted, there is very little in the literature to substantiate this. This study attempts to quantify the influence of constraint and various indications upon functional outcome following aseptic first time revision knee arthroplasty. The null hypothesis was that the level of constraint and indication for surgery would not influence the functional outcome following revision knee replacement. A single centre prospective study was performed to examine the outcome for 175 consecutive total revision knee replacements performed between 2003 and 2008 with a minimum follow-up of two years. Patient reported outcome data was used to determine the influence of final level of component constraint and its relationship with primary indication for surgery.Purpose
Methods
We wished to quantify the influence of constraint and various principal indications upon functional outcome following aseptic first time revision knee arthroplasty. In this single centre, prospective study we have looked into the outcome of 175 total revision knee replacement performed between 2003 and 2008 at a minimum follow-up of 1 year. Data was refined to allow for examination exclusively of those cases where the level of constraint was increased from cruciate retaining or cruciate sacrificing knee replacement to either non linked constrained implant (condylar constrained) or linked constrained (rotating hinge) prosthesis.Introduction
Methods