To assess the reliability of a biomimetic osteochondral scaffold Maioregen (Finceramica Faenza SpA, Faenza, Italt) as a salvage and joint-preserving procedure in the treatment of late stages of osteonecrosis of the knee. Nine active patients aged under 65 year presenting with clinical and radiological signs of SPONK were treated with a biomimetic osteochondral scaffold. All patients were clinically evaluated preoperatively and yearly with a minimum follow-up of 2 years. Subjective IKDC and Lysholm Knee Scale were used to assess clinical outcome. Pre-operative and post-operative pain was quantified with VAS scale. Activity level were evaluated pre-operatively and at follow-up according to Tegner Activity Scale.Purpose
Methods
Osteochondral lesions of the knee are relatively common both in young and senior population. The very disabling clinical symptoms, in association to the scarce regenerative capacity of the articular cartilage and the increased risk of developing a secondary osteoarthritis make an effective treatment mandatory. From December 2008 to January 2013, 34 patients (35 knees), 24 males and 10 females (mean age 36.2 years range 14–66) underwent implant of Maioregen® (Finceramica Faenza S.P.A, Italy) biomimetic tri-layer osteochondral scaffold. In 17 cases the osteochondral lesion was cause by an osteochondritis dissecans (acute or sequela), in 13 cases by a spontaneous osteonecrosis and in 4 cases the etiology was traumatic. Patients were evaluated with subjective IKDC and Tegner Lysholm scores, VAS and Tegner Activity Scale before surgery and at regular follow up (mean follow up 38.4 months, range 13 months max 63 months).Purpose
Methods and Materials
Osteochondral lesions of the knee are relatively common both in young and senior population. The very disabling clinical symptoms, in association to the scarce regenerative capacity of the articular cartilage and the increased risk of developing a secondary osteoarthritis make an effective treatment mandatory. From December 2008 to January 2013, 34 patients (35 knees), 24 males and 10 females (mean age 36.2 years range 14–66) underwent implant of Maioregen® (Finceramica Faenza S.P.A, Italy) biomimetic osteochondral scaffold. In 17 cases the osteochondral lesion was cause by an osteochondritis dissecans (acute or sequela), in 13 cases by a spontaneous osteonecrosis and in 4 cases the etiology was traumatic. Patients were evaluated with subjective IKDC and Tegner Lysholm scores, VAS and Tegner Activity Scale before surgery and at regular follow up (mean follow up 38.4 months, range 13 months max 63 months).INTRODUCTION
MATERIALS AND METHODS
Different surgical approaches have been proposed for the treatment of chondral lesions. However surgical management of osteochondral defects of the knee joint involving subchondral bone are still under debate. The aim of this prospective non-randomized uncontrolled clinical investigation is to confirm the effectiveness of a commercially available biomimetic osteochondral scaffold in regenerating cartilage and subchondral bone of severe osteochondral lesions of the knee joint with one step surgery.Background:
Purpose:
The aim of this study was to evaluate the efficacy of Hyalograft®-C, in a group of patients with full thickness patellofemoral defects.
Autologous chondrocyte transplantation has become a possible solution for the treatment of chondral knee lesions. Recently an autologous tissue engineered cartilage (Hyalograft C), using biodegradable scaffolds for cell proliferation, was successfully developed. In osteochondritis dissecans (OCD) the lesion also involves subchondral bone. For this reason we began to use a two-step technique: arthroscopic autologous bone grafting followed by autologouos condrocyte Hyalograft C transplantation after 4–6 months. We treated five patients affected by OCD. All the patients were clinically evaluated and analysed according to the International Repair Cartilage Society score at 12 and 24 months. The ICRS score showed highly satisfactory clinical results in all treated patients at 12 and 24 months; CT and MRI evaluation had demonstrated a good articular surface reconstruction with complete bone defect restoration at a short 12-month follow-up period. The autologous chondrocyte transplantation provides highly satisfactory clinical results. This second-generation autologous tissue-engineered cartilage transplantation avoids the use of periosteal flap, simplifies the surgical procedure and permits use of an arthroscopic approach. In association with autologous bone grafting, bone loss can also be restored in order to recreate a perfect articular surface. The preliminary clinical and histological results are encouraging but longer follow-up is required to better evaluate this technique.