header advert
Results 1 - 4 of 4
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 53 - 53
1 Feb 2020
De Meo F Ascani D Cacciola G Bernardoni M Cavaliere P
Full Access

Preoperative planning is a crucial step for total hip arthroplasty (THA), and 2D X-ray images are commonly used. The planning aims to provide the correct implant size, restore functional biomechanical conditions and avoid early complication such as dislocation, leg length discrepancy or abductors insufficiency. Limitations of 2D planning, besides the low accuracy in sizing, concerns the inability of planning the anteversion of both acetabular and femoral component on axial plane. Also, the verification of the planning intraoperatively is wholly left to qualitative measurements and the surgeon's experience. The need for having a more accurate and functional preoperative planning has been addressed using 3D models. The MyHip Planner (MHP) (Medacta International, Castel San Pietro, Switzerland), is a preoperative planning software which through artificial intelligent algorithm converts the CT scans into a 3D model that perfectly match the patient's anatomy. Then, automatic positioning of the implants is performed following the personal settings of the surgeon which will check and validate the planning, a personalized simulation of six daily activities to detect impingement of implants and bones. The MyHip Verifier (MHV) intraoperatively verifies the execution of the planning in terms of leg length and offset using two fluoroscopic images. Also, the size and cup angles can be calculated. The purpose of the present study was to validate the accuracy of the MHP [Fig 1] and MHV [Fig 2].

The dataset consisted of 13 patients who underwent primary uncemented THA. Each patient had a preoperative CT scan, intraoperative fluoroscopy, and postoperative CT scan after the surgery. The CT protocol used was low radiation (0,2 mm slicing for the pelvis, 0,5 mm for knees and ankles). The patients have been preoperatively planned used the MPH, and the accuracy of the components size prediction has been evaluated by comparing the preoperative planned values with the surgical reports. The MVH calculated the leg length and offset in terms of the difference between the preoperative and postoperative position of the femur concerning the pelvis. The accuracy of the measurements has been evaluated using postoperative CT scans. The MPH was able to predict the implanted size in 83% of the patient for the femoral stem and 96% for the acetabular component. The accuracy of the MVH in measuring the leg length was under 2 mm (1,6 ± 0,7 mm) while the offset was 2,5±1,6 mm. The cup angles were 5±1,1deg and 2,3±1,3deg for the anteversion and inclination, respectively. The average cup anteversion was 28,3°, mean cup inclination was 42,6°; femoral offset and leg length was restored in 96,5% of patients within a range of ±3 mm concerning the preoperative position. The results demonstrated the reliability of the MPH in predicting the implant size, and the accuracy of the MVH to verify the execution of the plan intraoperatively. The two software can be used in the clinical routine to improve the clinical outcome in THA. Limitations of this study are represented mainly by the small cohort of patients involved.

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 40 - 40
1 May 2016
Bergadano D Lambert P Bernardoni M Siccardi F
Full Access

Since its introduction in total hip replacements in the 1960's, Ultra High Molecular Weight Polyethylene (UHMWPE) has played a major role as a bearing component material for joint arthroplasty. Concerns were raised when issues of wear resistance became apparent, and therefore Highly Crosslinked Polyethylenes were introduced. Such materials undergo a thermal treatment to quench the free radicals and reduce progressive oxidation.

However, said thermal treatment weakens the material mechanical properties and hence the use of antioxidants has been proposed and implemented in clinical use, mainly Vitamin-E. This can be added to the material before or after irradiation. If it is done before, part of the anti-oxydant is consumed during irradiation and so will not be available for its main purpose, and part reacts before irradiation with the free radicals thus reducing the crosslinking effect. If it is added after irradiation, high temperatures are required in order to diffuse it in the bulk material, and anyway the surface will be mainly rich in antioxidant. However, Vitamin-E tends to neutralize the free radicals on the oxidized lipid chain present in our body fluids and so in direct contact with the prosthetic components: such mechanism reduces the Vitamin-E quantity available for anti-oxidation purposes in the long run.

A UHMWPE doped with Hindered Amine Light Stabilizer (HALS) has been developed and tested for applications in large joint replacements where highest resistance to wear and tough mechanical properties are simultaneously required, such as tibial inserts for knee joints or acetabular inserts for large diameter heads.

Mechanical and biocompatibility tests were run in accordance with ASTM F 2565-06 and ISO 10993-1 with successful results and good reproducibility.

In particular, electro spin resonance exhibited a very high level of free radicals in the three samples, which confirms the properties of this new material. Free radicals are the result of the activation of the HALS molecules during irradiation, creating nitroxide radicals that will destroy the residual alkyl radicals responsible for the oxidation before and after implantation.

Biocompatibility tests proved absence of cytotoxicity, sensitization, irritation, genotoxicity or pyrogenic reactions.

The possible future applications for this new material in the arthroplasty field will be discussed along with the expected advances and advantages.


Introduction

Patient-specific cutting guides entered into clinical practice few years ago, first introduced in total knee replacement and recently also for other joint replacements. Advantages claimed are improving accuracy and repeatability in implant placement. New patient-specific guides to perform an accurate femoral neck resection and provide a precise alignment reference for acetabular reaming in total hip arthroplasty (THA) were recently developed by Medacta International: MyHip Technology. To date femoral guides can be designed for both anterior and posterior approaches, whereas acetabular guides are available only for posterior approach.

Evaluation of the repeatability and reproducibility of MyHip guides placement on cadavers is performed using a navigation system. Accuracy of femoral MyHip guides is evaluated also through one author's clinical experience (RP).

Materials and Methods

During each cadaveric session one body (2 hips) was available. A pre-operative CT scan has been obtained and used in order to create the 3D bone model of the pelvis and proximal femurs. Afterwards, a surgical planning for THA has been performed for each case, and, once it was approved by the surgeons, the designed patient-specific blocks were made.

Intraobserver and interobserver agreement in positioning the guides was assessed getting measures of femoral head resection height (mm), femoral head plane inclination/anteversion (°) and acetabular reaming axis orientation (°). 9 surgeons, through 2 cadaveric sessions, positioned each guide, removed it and re-positioned it 5 times alternatively. The system is judged as accurate if all measures differ less than 3mm and 5°for lengths and angles respectively from the average among all the acquisitions.

Clinical experience includes 68 THA which were performed between March 2014 and April 2015. Anterior femoral MyHip guides were used for the femoral head resection, while the acetabular side was prepared using the standard metal instrumentation for minimally invasive anterior approach. Intra-operative complications, as well post-operative leg length difference and implant positioning are assessed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 27 - 27
1 Dec 2013
Charbonnier C Chague S Ponzoni M Bernardoni M Hoffmeyer P Christofilopoulos P
Full Access

Introduction

Conventional pre-operative planning for total hip arthroplasty mostly relies on the patient radiologic anatomy for the positioning and choice of implants. This kind of planning essentially remains a static approach since dynamic aspects such as the joint kinematics are not taken into account. Hence, clinicians are not able to fully consider the evolving behavior of the prosthetic joint that may lead to implant failures. In fact, kinematics plays an important role since some movement may create conflicts within the prosthetic joint and even provoke dislocations. The goal of our study was to assess the relationship between acetabular implant positioning variations and resultant impingements and loss of joint congruence during daily activities. In order to obtain accurate hip joint kinematics for simulation, we performed an in-vivo study using optical motion capture and magnetic resonance imaging (MRI).

Methods

Motion capture and MRI was carried out on 4 healthy volunteers (mean age, 28 years). Motion from the subjects was acquired during routine (stand-to-sit, lie down) and specific activities (lace the shoes while seated, pick an object on the floor while seated or standing) known to be prone to implant dislocation and impingement. The hip joint kinematics was computed from the recorded markers trajectories using a validated optimized fitting algorithm (accuracy: translational error ≍ 0.5 mm, rotational error < 3°) which accounted for skin motion artifactsand patient-specific anatomical constraints (e.g. bone geometry reconstructed from MRI, hip joint center) (Fig. 1).

3D models of prosthetic hip joints (pelvis, proximal femur, cup, stem, head) were developed based on variations of acetabular cup's inclination (40°, 45°, 60°) and anteversion (0°, 15°, 30°) parameters, resulting in a total of 9 different implant configurations. Femoral anteversion remained fixed and determined as “neutral” with the stem being parallel to the posterior cortex of the femoral neck. Motion capture data of daily tasks were applied to all implant configurations.

While visualizing the prosthetic models in motion, a collision detection algorithm was used to locate abnormal contacts between both bony and prosthetic components (Fig. 2). Moreover, femoral head translations (subluxation) were computed to evaluate the joint congruence.