Bernárdez DC Roa-Montero J Cachero-Rodríguez N Pérez-Rodríguez S
Full Access

Introduction and purpose: The purpose of the study is to look at the progress of fixed implants with osteolysis and bone defects treated and to set ground rules for treatment guidelines.

Materials and methods: We reviewed 204 hips between March 1996 and March 2003, in 40 of which femoral osteolysis was treated with fixed prostheses.

The reasons for the revisions were 20 aseptic cup loosenings and 20 cases of worn polyethylene, with presence of femoral osteolysis. Thirty of the stems were biological, nine mini-madreporic and one cemented.

The mean follow-up was 5 years and 2 months.

We used morsellised impacted bone graft held in place with cement, metal laminas or bone stock.

Results: Clinically the outcome was excellent or good in 92.5% of the cases, with no migration or revision of the stem.

All the grafts took. There was very limited partial resorption in 20% of the cases and radiolucent lines in 20.6%.

Among the complications were two new cases of wear with osteolysis and a fractured femur caused by a fall, with no infection or dislocation.

Conclusions: Femoral osteolysis must be watched and treated surgically if it progresses, even though the implant is fixed.

Impacted morsellised bone grafts in the femoral canal with a fixed stem, even with extensive, unchecked osteolysis, held in place with metal cages are a reliable means of recovering bone stock and holding the femoral component firmly in place for the long term, with good clinical and radiological outcome, minimal risk and shorter surgery.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 67 - 67
1 Mar 2006
Cachero N Rodríguez NC Bernárdez DC Algora J
Full Access

Introduction: The Arc2F is a cementless hemispheric threaded acetabular cup fabricated from titanium alloy (TI-6Al-4V) with a HA porous coating and dome holes for screws.

Materials and methods: We evaluated fifty one cups in forty nine patients under revision surgery. The average duration of follow-up was 9.8 years (range, 7–13 years). Mean age at time of revision surgery was 62.2 years (range, 41–76 years). 55.1% of the patients were women and 44.9% were men.

Preoperative diagnoses were: painful aseptic loosening in 41 cups (25 cementless and 16 cemented acetabular components), 8 acetabular protusio with unipolar hemiprosthesis and two cronic infections.

Acetabular bone deficiencies were classified as segmental in 19.6 %, cavitary in 37.3 % and combined in 43.1% according to the AAOS. Bone graft was used in 72.5 %.

Clinical and radiographic results were rated according to the Johnston et al and Merle D’Aubigne scores.

Results: The result was excellent in 60.8%, good in 29.4%, fair in 7.8%, and poor in 2%. At the time of the last follow-up, 76.5% were not painful.

The acetabular component was categorized as stable in 50 (98%), with two cases of migration in the first three months. Only one component was categorized as loose. No acetabular cup were removed or revised again.

Radiolucent lines were maximum in zone 5: 5.9% (Include the migrated component).

The most frequent complication was dislocation, which occurred in 3 hips (5.9%). Pelvic osteolysis was present in 5.9%.

Discussion: The Arc2F acetabular cup shows excellents results in revision surgery with a good primary fixation and long-term osseointegration.