Extensor mechanism disruption in total knee arthroplasty (TKA) occurs infrequently but often requires surgical intervention. We compared two cohorts undergoing extensor mechanism allograft reconstruction, one group had an extensor mechanism rupture, and the other had a recurrent ankylosed knee. Thirteen consecutive patients with extensor mechanism disruption or ankylosis after TKA were treated. Two different types of extensor mechanism allografts were used: quadriceps tendon-patella-patella tendon-tibial tubercle, and Achilles tendon allograft(Fig1). Demographic factors, diagnosis at extensor failure, Knee Society clinical rating scores, radiographs, and patient satisfaction were recorded. The average time from extensor mechanism disruption to surgery was 6.6 months (range, 1-24 months). At a mean followup of 24 months (range, 6-46 months), all patients were community ambulators. None of the patients showed a postoperative extensor lag. Average postoperative maximum flexion was 97° (90-115°) for the ruptured group and 80° (75-90) for the ankylosed grup. All patients thought their functional status had improved, and 87% were satisfied with the results of the allograft reconstruction (Fig 2, 3, 4, 5). One patient had allograft failure due to recurrent infection after re-revision for sepsis. The total extensor mechanism allograft and Achilles tendon allograft both were successful in the treatment of the failed extensor mechanism and showed promising results for the treatment of the ankylosed knee.