Advertisement for orthosearch.org.uk
Results 1 - 20 of 53
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 24 - 24
1 Jun 2017
Jonas S Bick S Whitehouse M Bannister G Baker R
Full Access

We compared the long-term clinical and radiological results of hybrid total hip replacement (THR) with metal-on-metal Birmingham hip resurfacing (BHR) in two groups of 54 young patients matched for age, gender, body mass index and pre-operative levels of activity.

The clinical outcome was assessed by the University of California, Los Angeles (UCLA) activity score, the Oxford Hip Score (OHS) and the EuroQol scores. Radiologically, all hips were assessed for migration and osteolysis, the hybrid THRs for polyethylene wear and the BHRs for a pedestal sign.

The mean follow-up of the patients with a hybrid THR was 16 years and for those with a BHR, 15 years. 12 patients with a hybrid THR and 6 with a BHR had died. 2 patients with a BHR refused follow up but remain unrevised and 5 were lost to follow-up, as was 1 with a hybrid THR. The revision rate of the hybrid THRs was 28% (15 of 54) and of the BHRs 11% (6 of 54) (p = 0.029). Radiographs of a further 13 hybrid THRs demonstrated wear and osteolysis but are functioning well and are under observation. Of the unrevised BHRs 96% had radiological changes, of which approximately 17% had progressed over the previous 6 years. All hybrid THRs demonstrated linear polyethylene wear with a mean of 1.84mm (0.06 to 2.6). The BHRs recorded superior OHS (p = 0.03), UCLA (p = 0.0096), and EuroQol visual analogue scores (p = 0.03).

After 15 years, patients with BHRs remained more active and had a lower rate of revision and death than those with hybrid THRs. Both groups demonstrated progressive radiological changes at long-term follow-up.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 30 - 30
1 Apr 2017
Islam N Whitehouse M Mehandale S Blom A Bannister G Ceredig R Bradley B
Full Access

Background

Post-traumatic immunosuppression (PTI) after surgery increases vulnerability to nosocomial infections, sepsis, and death. Knee arthroplasty offers a sterile clinical model to characterise PTI and explore its underlying mechanisms.

Methods

This prospective non-randomised cohort study of primary total knee arthroplasty was approved by the Local Ethics Committee. Exclusion criteria included revision-arthroplasty, pre-existing infections, blood-transfusions, malignancy, and auto-immune disease. 48 recruited patients fell into two groups, the first received unwashed anti-coagulated autologous salvaged blood transfusions after surgery (ASBT cohort, n=25). The second received no salvaged blood transfusions (NSBT cohort, n=18). Venous blood was sampled pre-operatively and within 3–7 days post-operatively. Salvaged blood was sampled at one and six hours post-operatively. Biomarkers of immune status included: interleukins (IL) or cytokines (x15), chemokines (x3), Damage-Associated-Molecular-Patterns (DAMPS) (x5), anti-microbial proteins (x3), CD24, and Sialic-acid-binding-Immunoglobulin-type-Lectin-10 (Siglec-10). Results were expressed as fold-change over pre-operative values. Only significant changes are described.


Bone & Joint 360
Vol. 1, Issue 5 | Pages 33 - 33
1 Oct 2012
Bannister G


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 108 - 108
1 Sep 2012
Burston B Barnett A Amirfeyz R Yates P Bannister G
Full Access

We have prospectively followed up 191 consecutive primary total hip replacements utilising a collarless polished tapered (CPT) femoral stem, implanted in 175 patients between November 1992 and November 1995.

At a mean follow-up of 15.9 years (range 14 – 17.5) 86 patients (95 hips) were still alive (25 men and 61 women) and available for routine follow up. Clinical outcome was determined from a combination of the Harris (HHS) and Oxford (OHS) hip scores. Radiological assessment was with antero-posterior radiographs of both hips and a lateral radiograph of the operated hip. The radiographs were evaluated using well-recognised assessment techniques.

There was no loss to follow up, with clinical data available on all 95 hips. Five patients were too frail to undergo radiographic assessment, therefore radiological assessment was performed on 90 hips (95%). At the latest follow-up, the mean HHS was 78 (range 28 – 100) and the mean OHS was 36 (range 15 – 48). Stems subsided within the cement mantle, with a mean total subsidence of 2.1mm (range 0.4 – 24). Higher grades of heterotopic bone formation were significantly associated with males (p<0.001) and hypertrophic osteoarthritis (p<0.001). Acetabular wear was associated with increased weight (p<0.001) and male sex (p=0.005). Amongst the cohort, only 1 stem (1.1%) has been revised due to aseptic loosening. This patient required reaming of their canal prior to implantation, as a result of a previous femoral osteotomy. The rate of stem revision for any cause was 7.4% (7 stems), of which 4.2% (4 stems) resulted from infection following revision of the acetabular component. Twenty patients (21.1%) required some sort of revision procedure; all except 3 of these resulted from failure of the acetabular component. Cemented cups had a significantly lower revision burden (2.7%) than Harris Galante uncemented components (21.8%) (p<0.001).

The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation. Its results are consistent with other polished tapered stem designs. Cup failure remains a problem and is related in part to inadequate bearings and biological abnormalities.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 3 - 3
1 May 2012
Butt U Ahmad R Aspros D Bannister G
Full Access

Wound ooze is common following Total Knee Arthroplasty and persistent wound ooze is a risk factor for infection, increased length and cost of hospitalisation. We undertook a prospective study to assess the effect of tourniquet time, periarticular local anaesthesia and surgical approach on wound oozing after TKA. The medial parapatellar approach was used in 59 patients (77%) and subvastus in 18 patients (23%). Periarticular local anaesthesia (0.25% Bupivacaine with 1:1000000 adrenalin) was used in 34 patients (44%). The mean tourniquet time was 83 minutes (range 38 to 125 minutes). We found a significant association between cessation of oozing and periarticular local anaesthesia (P = 0.003), length of the tourniquet time (P = 0.03) and the subvastus approach (P = 0.01). Periarticular local anaesthesia, the subvastus approach and shorter tourniquet time were all associated with less wound oozing after total knee arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XII | Pages 17 - 17
1 Apr 2012
Maclean A Bannister G Murray J Lewis S
Full Access

Last minute cancellations of operations are a major waste of NHS resources. This study identifies the number of late cancellations at our elective orthopaedic centre, the reasons for them, the costs involved, and whether they are avoidable.

Last minute cancellations of operations in a 7-month period from January to July 2009 were examined.

172 cases out of 3330 scheduled operations were cancelled at the last minute (5.2%). Significantly more cancellations occurred during the winter months due to seasonal illness.

The commonest causes for cancellation in descending order of frequency were patient unfit/unwell (n=76, 44.2%), lack of theatre time (n=32, 18.6%), patient self cancelled/DNA (n=20, 11.6%), staff unavailable or sick (n=9, 5.2%), theatre or equipment problem (n=8, 4.7%), operation no longer required (n=8, 4.7%), administrative error (n=7, 4.1%) or no bed available (n=5, 2.9%). In 7 out of the 172 cancelled cases (4.1%) no cause was identified. 59.7% of the cases were potentially avoidable.

3.2% of Patients seen in the specialist pre-operative anaesthetic clinic (POAC) were cancelled at the last minute for being unfit or unwell, compared to 2.2% seen in the routine nurse led clinic. Last minute cancellations cost the hospital over £700,000 in 7 months.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XII | Pages 9 - 9
1 Apr 2012
Avery P Rooker G Walton M Gargan M Baker R Bannister G
Full Access

Long-term prospective RCT comparing hemiarthroplasty (HEMI) and total hip arthroplasty (THA) for the treatment of intracapsular neck of femur fracture.

81 previously mobile, independent, orientated patients were randomised to receive THA or HEMI after sustaining a displaced neck of femur fracture. Patients were followed up with radiographs, Oxford hip score (OHS), SF-36 scores and their walking distance.

At a mean follow up of 8.7 years, overall mortality following THA was 32.5% compared to 51.2% following HEMI (p=0.09). Following THA, patients died after a mean of 63.6 months compared to 45 months following HEMI (p=0.093). Patients with THA walked further and had better physical function. No HEMIs dislocated but three (7.5%) THAs did. Four (9.8%) HEMI patients were revised to THA, but only one (2.5%) THA required revision. All surviving HEMI patients had acetabular erosion and all surviving THA patients had wear of the cemented polyethylene cup.

Patients with THA have better function in the medium-term and survive longer.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 157 - 157
1 Mar 2012
Bannister G Ahmed M Bannister M Bray R Dillon P Eastaugh-Waring S
Full Access

We compared the early complication rates of total hip (THA) and total knee (TKA) arthroplasty carried out at a regional orthopaedic hospital (AOC) and two Independent Sector Treatment Units (ISTUs) (WGH and CNH). After THA, reoperation rates were higher at CNH (9%) than AOC (0.6%) or WGH (1.4%). After TKA, reoperation rates at CNH were (8%) higher than AOC (1%) and WGH (1.9%).

5% of patients undergoing TKR at CNH underwent 2 stage revision for deep infection.

After THA, dislocation rates at CNH (6%) were higher than AOC and WGH (1.8%). Readmission from CNH (13%) was higher than AOC (1.2%) and WGH (0.6%).

Major wound problems at CNH (20%) were higher than WGH (3.8%) and AOC (0.4%).

After TKA, major wound problems were higher at CNH (19%) compared to WGH (1.9%) and AOC (1.1%). Readmission rates not requiring surgery from CNH (13%) were higher than AOC. (1.1%) and WGH (1%). AOC and WGH audited their outcomes. None were available from CNH. WGH initially missed many of their complications because they presented at base hospitals elsewhere.

ISTUs performed approximately 2/3rds of procedures for which patients had been referred from base hospitals.

At CNH, 23% were rejected on grounds of potential co-morbidity. Audit from ISTUs is inferior to NHS hospitals and the results in one of those audited significantly worse.

Patients offered surgery at ISTUs should be told that the audited outcome of the surgeon who will be treating them is not known and that, in some, results are inferior to surgery in the NHS.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 58 - 58
1 Feb 2012
Hook S Moulder E Burston B Yates P Whitley E Bannister G
Full Access

We reviewed 142 consecutive primary hip arthroplasties using the Exeter Universal femoral stem implanted between 1988 and 1993 into 123 patients. 74 patients with 88 hips survived to 10 years or more and were reviewed with a mean 12 years 8 months. There was no loss to follow-up and the fate of all stems is known.

Our stem revision rate for aseptic loosening and osteolysis was 1.1% (1 stem); stem revision for any cause was 2.2% (2 stems); and re-operation for any cause was 21.6% (19 hips), all but 2 of which were due to cup failure.

All but one stem subsided within the cement mantle to an average of 1.5mm at final follow-up (0 to 8mm). One stem was revised for deep infection and one was revised for excessive periarticular osteolysis. One further stem had subsided excessively (8mm) and demonstrated lucent lines at the stem-cement and cement-bone interfaces. This was classified as a radiological failure and is awaiting revision. 28% of stems had cement mantle defects, which were associated with increased subsidence (p=0.01), but were not associated with endosteal lysis or stem failure.

Periarticular osteolysis was significantly related with the degree of polyethylene wear (p<0.001), which was in turn associated with younger age patients (p=0.01) and males (p<0.001).

The Exeter metal backed cups were a catastrophic failure with 34% revised (11 cups) for loosening. The Harris Galante cups failed with excessive wear and osteolysis, with failure to revision of 18%. Only 1 cemented Elite cup was revised for loosening and osteolysis (4%).

The Exeter Universal stem implanted outside the originator centre has excellent medium term results.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 57 - 57
1 Feb 2012
Burston B Yates P Hook S Moulder E Bannister G
Full Access

Introduction

The success of total hip replacement in the young has consistently been worse both radiologically and clinically when compared to the standard hip replacement population.

Methods

We describe the clinical and radiological outcome of 58 consecutive polished tapered stems (PTS) in 47 patients with a minimum of 10 years follow-up (mean 12 years 6 months) and compared this to our cohort of standard patients. There were 22 CPT stems and 36 Exeter stems.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 144 - 144
1 Feb 2012
Pollard T Baker R Eastaugh-Waring S Bannister G
Full Access

Metal-on-metal resurfacing offers an alternative strategy to hip replacement in the young active patient with severe osteoarthritis of the hip. The aim of this study was to compare functional outcomes, failure rates and impending revisions in hybrid total hip arthroplasties (THAs) and Birmingham Hip Resurfacings (BHRs) in young active patients.

We compared the 5-7 year clinical and radiological results of the metal-on-metal BHR with hybrid THA in two groups of 54 hips each, matched for sex, age, body mass index and activity. Function was excellent in both groups as measured by the Oxford hip score (median 13 in the BHRs and 14 in the THAs, p=0.14), but the resurfacings had higher UCLA activity scores (median 9 v 7, p=0.001) and better EuroQol quality of life scores (0.90 v 0.78, p=0.003). The THAs had a revision or intention to revise rate of 8% and the BHRs 6%. Both groups demonstrated impending failure on surrogate end-points. 12% of THAs had polyethylene wear and osteolysis under observation, and there was femoral component migration in 8% of resurfacings. Polyethylene wear was present in 48% of hybrid hips without osteolysis. Of the femoral components in the resurfacing group which had not migrated, 66% had radiological changes of unknown significance (classification proposed).

In conclusion, the early to mid-term results of resurfacing with the BHR appear at least as good as those of hybrid THA. Only by longer term follow-up will we establish whether the change of practice recorded here represents a true advance.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 80 - 80
1 Feb 2012
Sabri O Bosman H Bould M Bannister G
Full Access

Nationwide, proximal femoral fractures contribute a significant workload for the NHS and are the commonest trauma admission. Timely discharge from the acute hospital setting is beneficial to both patient and orthopaedic team.

The Community Care Act 2003 formed part of Governmental strategy to reduce ‘bed blocking’. Introduced on 5 January 2004, the scheme enabled Trusts to charge Local Authorities £100 a day where there was delayed transfer of care due to lack of Social Service [SS] provision. The Act brought with it a £250 million package of funding over three years.

We looked at patients admitted to Weston Area Healthcare Trust [WAHT] sustaining fractured neck of femur. These were pre-scheme group A, admitted 08/09/2003-06/10/2003 and post scheme group B, 08/03/2004 – 05/04/2003. Patient numbers, group ‘A’ 33 patients, group ‘B’ 28 patients. Average length of stay, ‘A’ 22.3 days, ‘B’ 16.1 days. The average time spent in hospital after being declared ‘medically fit’, ‘A’ 6.6 days, ‘B’ 2.3 days. Only 13 patients were referred to SS post scheme, with combined delayed discharge of 116 days.

The impact of the scheme in reducing length of stay has not been proven. Few patients were referred to SS even after the implementation of the scheme; however, the delay in discharge for these patients would have amounted to £11600 of funding. To date, WAHT have not received any funds for patients in whom discharge was delayed.

The Act states that lack of SS input must be the ‘sole reason’ for delay in discharge. The scheme is not applicable if delay is due to family choice, lack of equipment or lack of intermediate care package and for these reasons transfer of funds from SS to Trusts has become a multidisciplinary minefield. The impact of the reimbursement scheme will only become apparent if the Act is enforced.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 548 - 549
1 Nov 2011
Avery P Walton M Rooker G Gargan M Squires B Baker R Bannister G
Full Access

Introduction: We report on the long-term follow up of a previously published randomised controlled trial comparing Hemiarthroplasty (HEMI) and total hip arthroplasty (THA) for the treatment of intracapsular fracture neck of femur.

Methods: In this prospectively randomized study, 81 patients who had been mobile and lived independently and who sustained a displaced fracture of the femoral neck were randomized to receive either a fixed acetabular component THA or HEMI. The mean age of the study group was 75 years at fracture. All patients received the same cemented collarless tapered femoral stem and all procedures were performed through a transgluteal approach. Patients were followed up with radiographs, Oxford hip score (OHS), SF-36, Euroqol and their walking distance.

Results: At a mean follow-up of 8.6 years (7.18 to 10.27), 19 HEMI patients and 27 THA were alive (p=0.042). The mean walking distance of patients after HEMI was 600m and the OHS 21. After THA, the mean walking distance was 1200m and the OHS was 22. Both groups had a deterioration of their OHS over time. There were no significant differences between the groups with respect to both physical and mental component SF-36 scores and Euroqol visual analogue scores.

Of the survivors four of the HEMI group were revised to total hip arthroplasty. One patient had been revised in the THA group. Radiographically six of seven patients in the HEMI group had evidence of acetabular erosion and 13 of 15 patients in the THA group had a lucency around their acetabular component.

Discussion: Patients with THA walked further and survived longer. After a mean of nine years follow up there was no difference with respect to function as measured by OHS, Euroqol and SF-36 scores.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 548 - 548
1 Nov 2011
Baker R Pollard T Eastaugh-Waring S Bannister G
Full Access

Introduction: We compared the eight- to ten-year clinical and radiological results of the metal-on-metal Birmingham hip resurfacing (BHR) with a hybrid total hip arthroplasty (HYBRID) in two groups of 54 hips, previously matched for gender, age, body mass index and activity level.

Method: Patients were followed up in outpatients and function assessed by using the Oxford Hip Score, UCLA activity score and Euroqol score. Radiographs were assessed for osteolysis and wear. BHR were also assessed for the presence of a pedestal sign around the femoral component.

Results: The mean follow up of the BHR group was 9 years (8.17 to 10.33) and for hybrids 10 (7.53 to 14.5). Four patients had died in the hybrid group and one in the BHR. Four were lost to follow up in each group. The revision rate in the BHR group was 9.25% verses 18% in the Hybrid, a further eight patients in the hybrid group have evidence of wear and osteolysis and are intended for revision (p=0.008). One patient in the BHR group was explored for late onset sciatic nerve palsy. All patients in the hybrid group had evidence of polyethylene wear, mean 1.24mm (0.06–3.03). 90% of the BHR group had evidence of a pedestal sign.

Satisfactory function was shown in both groups. There was no significant difference between groups with respect to the OHS but the UCLA score was superior in the BHR group (p=0.008). There was no significant difference for Euroqol visual analogue score. 56% of hybrids were delighted with their hip replacement verses 65% of BHR patients.

Discussion: After ten years the hip resurfacing patients were still more active and had a lower revision burden than the hybrid hip replacements. Both groups showed worrying radiological evidence of change with long-term follow-up.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 139 - 139
1 May 2011
Clark D Amirfeyz R Parsons B Melotti R Bannister G Leslie I Bhatia R
Full Access

Clinician expectation and anatomical studies suggest that the distribution of sensory dysfunction in carpal tunnel syndrome (CTS) should be confined to the thumb, index, middle and half of the ring fingers. We mapped the distribution of disturbance to evaluate the accuracy of these assumptions.

We evaluated 64 wrists in 64 patients with nerve conduction study confirmed CTS. Each patient filled out a Katz hand diagram and we collated the distribution of pain and non-painful (tingling, numbness & decreased sensation) sensory disturbance. Frequency of reporting was analysed; dividing symptoms into thenar and hypo-thenar eminence, distal palm, each digit, posterior hand and forearm.

Non-painful sensory disturbance occurred in all patients. The index finger was the most common location (94%) followed by the middle finger (91%), the distal palm (84%), the ring finger (72%), the thumb (69%), the thenar eminence (63%), the little finger (39%), the dorsal hand (31%), the hypothenar eminence (25%) and the forearm (13%).

Pain was less common, reported in 59% of cases. Pain occurred most frequently over the wrist crease (33%) followed by thenar eminence (27%), the forearm (20%), the middle finger (23%), the index finger (22%), the ring finger (19%), the distal palm (16%), the thumb (14%), the dorsal hand (11%), the little finger (11%) and least frequently the hypothenar eminence (6%)

In CTS sensory disturbance occurs most frequently in the median nerve distribution; however it occurs almost as often elsewhere. An atypical distribution of symptoms should not discourage diagnosis of CTS.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 87 - 87
1 May 2011
Whitehouse M Atwal N Blom A Bannister G
Full Access

Introduction: Radiolucency in the DeLee and Charnley zone 1 of the acetabulum in the early post operative period is a strong predictor of long-term failure of the cemented acetabulum. There is a wide variety in the acetabular anatomy of patients presenting for total hip replacement. Zone 1 radiolucency is an indicator of the failure of penetration of cement into the relatively hard cortical bone encountered in zone 1. Cement penetration is achieved by adequate preparation, achieving containment and effective pressurisation.

Aim: To use pre operative radiological measurements to predict the risk of radiolucency around the cemented acetabular component post operation.

Hypotheses:

Dysplastic acetabuli are associated with a higher incidence of zone 1 radiolucency.

Retroverted acetabuli are associated with a higher risk of zone 1 radiolucency.

Radiolucencies progress in the early post operative period.

Materials and Methods: A cohort of 300 patients undergoing cemented THR in our institution was identified. Radiographs performed on the patients pre operatively, post operatively, at first follow up (6 weeks to 3months) and follow up at 1 year were analysed. The following measurements of the native acetabulum were performed: Tonnis grade of osteoarthritis, Crowe grade of dysplasia, acetabular index of depth to width, ACM angle, peak to edge distance, acetabular index of weight bearing zone, centre-edge angle of Widberg, acetabular angle of Sharp, cross over sign and posterior wall sign to assess retroversion, acetabular inclination and anteversion angle. Post operative films were then assessed for the presence of zone 1 keyholes, incidence and degree of radiolucency, cup inclination and anteversion.

Results: Patients with an acetabulum outside the normal range were more likely to have a post operative radiolucency. Radiolucency tended to progress with time. Zone 1 keyholes appeared to terminate this progression. Retroverted and steeply inclined acetabuli demonstrated a higher incidence of radiolucency. A large change in version from the native to prosthetic acetabulum was associated with an increased risk of radiolucency.

Conclusion: Thorough pre operative radiological assessment of the acetabular anatomy allows us to predict patients at high risk of post operative radiolucency. Patients with unsuitable anatomy may be more appropriate for an alternative method of fixation or require different techniques of acetabular preparation or augmentation in order to reduce their risk of loosening of the acetabular component in the long term.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 45 - 45
1 Jan 2011
Heal J Blom A Bannister G
Full Access

Stable fixation with macro and micro interlock prevents early migration and therefore early failure of cemented acetabular cups.

The authors describe a cementation technique in an in-vitro model that increases the interossoeous pressure by a factor of 3.5 in the ishium, 4.5 in the ilium and 5.1 in the pubis by the injection of the cement directly into the 10 mm key holes prior to insertion of the cement bolus and cup.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 46 - 46
1 Jan 2011
Davies D Longworth A Amirfeyz R Fox R Bannister G
Full Access

Introduction: The severity of symptoms, rate and completeness of recovery after closed treatment of the fractured clavicle has not been fully explored.

Materials and Methods: The severity and duration of pain, analgesic requirements, ability to perform acts of daily living, return to work, driving and sport were recorded along with appearance of the shoulder in 58 patients between one to two years after fracture was recorded. Radiographs were assessed by Robinson’s classification8 supplemented by fracture displacement.

Results: The majority of patients experienced severe pain that required codeine, paracetamol and ibuprofen. 13/58 patients (22%) ceased to experience pain by one month, 35/58 (60%) by three and 48/58 (83%) by six. There was no improvement in the remaining ten patients after six months.

21 patients described difficulty reaching and lifting (36%), 11/36 (31%) digging the garden, 13/58 (22%) were unable to reach between their shoulder blades. Over 90% had no difficulty with feeding (55/58), dressing (50/58), personal toilet (56/58), brushing hair (41/46), hanging up clothes (52/56) or ironing (37/41) but overall 23/58 patients (40%) had some functional restriction 1–2 years after injury. 18/48 patients (38%) returned to work within one month, 39 (81%) by three, and all by six. 28/30 (93%) clerical workers had returned within three months compared with 11/18 (61%) of manual (p < 0.05) 36/42 (86%) sportsmen returned. High impact sportsmen were less likely to resume than low impact or overhead. 38/46 (83%) of drivers returned by three months and all by six.

40/58 (69%) patients noted cosmetic deformity the severity of which was associated with worse functional outcome (p = 0.002). The degree of displacement of the fracture was associated with cosmetic deformity (p = 0.015) and functional outcome (p = 0.025), but the Robinson classification8 alone was not.

Conclusion: The majority of patients with a fractured clavicle perceive a cosmetic deformity and a substantial minority impaired function. There is potential to improve outcome and deformity by reduction and fixation in those with displacement of two or more cortical diameters.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 13 - 13
1 Jan 2011
Bosman H Mewton J Parsons B Bannister G
Full Access

Tibial shaft fracture occurs commonly in the young active population with high demands. Tibial fracture is potentially life changing. There are no published studies with long-term follow-up to provide accurate prognostic information regarding return to leisure activities, employment and driving.

We aim to define the patient demographic and mechanism of injury and quantify the time period following tibial shaft fracture to return to sport and sporting level achieved at long-term follow-up. A retrospective multi-centre study was performed. Data collection was by questionnaire including Tegner activity scale score for sporting level and closed questioning on employment and driving.

Ninety-three patients were recruited with an average 46 month (18–64mo) follow-up period. Patients were predominantly male (77%) with a median age at injury of 37 years. Road traffic accidents were responsible for 43% of injuries; sport 31%; falls 25% and assault 1%. High energy mechanisms accounted for 49% of injuries Seventy-eight percent of patients felt that prognostic information given at the time of injury was inaccurate.

At follow-up, only 31% had regained their original level of sporting ability. Median Tegner score prior to injury score was 5 and at 18 months the mean score fell by 1.85. Patients sustaining high energy injuries were worst affected, dropping an average of 2.13 compared to low energy mechanisms with an average fall of 1.35 on the Tegner scale (p=0.503). High demand patients had a greater reduction in functional outcome, with a fall of 0.8 for patients with pre-injury activity level of 1–3 compared to the fall of 2.6 on the scale for more active patients scoring 7–9 pre-injury.

Tibial fracture can result in significant long-term morbidity. Patients sustaining high energy injuries and high demand patients have significantly worse outcome. Patients are unlikely to achieve their pre-injury level of sporting activity at 2 years.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 567 - 567
1 Oct 2010
Massouh L Amirfeyz R Bannister G Whitcroft K
Full Access

Introduction: Cervical range of motion is affected by a wide variety of pathologies and is routinely measured in clinical assessment of the neck. It is therefore crucial to use a method that is both accurate and reliable but that is also non-invasive and inexpensive. This study assessed cervical range of motion using different methods of measurement, namely the universal goniometer and the cervical range of motion (CROM) goniometer. These methods were then compared with each other. In addition, we were interested in determining whether a single component of neck movement is representative of total cervical range of motion.

Methods: 50 healthy subjects between the ages of 18–87 with no shoulder or spine pathology were asked to perform six active neck movements, flexion, extension, lateral flexion and axial rotation while the movements were measured first using the universal goniometer and then with the CROM goniometer. The CROM goniometer has been shown previously to have excellent validity and reliability. The researchers were trained to use the measuring techniques prior to data collection. All measurements were performed by the same researcher for each subject and the two researchers alternated between subjects.

Results: Comparison between the universal goniometer and the CROM goniometer was performed using Bland and Altman plots. This revealed that 60.6% of universal goniometer readings were within ±5° of the CROM reading; however 31.6% of readings differed by > ±5° and 7.8% differed by > ±10°. The interobserver variance was calculated and there was excellent agreement between the two researchers for both the universal goniometer and CROM goniometer, with an intraclass correlation coefficient of ≥0.80 for every movement. Extension was the most predictive of total neck movement (Pearson coefficient 0.643, p < 0.001). This continues to be the case even when the negative effect of age on range of motion is taken into account.

Discussion: The finding that extension was the most representative neck movement has implications for the assessment of cervical motion. Accordingly, if a single neck movement is measured to represent total range of motion, extension should be used.

The comparison between the CROM and universal goniometer demonstrated that the majority of goniometer readings were within 5° of the CROM result; however, this was not consistently the case. Given that the CROM is a valid and reliable method of measuring neck movement, the inconsistency between the goniometer and CROM can be taken as inaccuracy on the part of the universal goniometer. As the interobserver variance is excellent one can assume that these results are reproducible and that the errors observed are a true reflection of the limitations of the device.