Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 6 - 6
1 Mar 2008
Bajwa A Bajwa S Wilson S Nellis J Finn P Williamson S Port A
Full Access

To evaluate blood transfusion practice in hip and knee arthroplasty, the development of evidence based guidelines, their implementation and prospective analysis of change. An audit was carried out in 4 stages to complete the loop. Stage 1: Retrospective analysis of blood transfusion practice in primary and revision hip and knee arthroplasty. Review of case notes, nursing record, anaesthetic sheet and pathology results from a computer database was carried out. Rates of transfusion, patients’ body weight and height, peri-and post-operative blood loss, use of anticoagulants, drains, surgical approach, type of implant and cement, grade of surgeon and anaesthetist and haemodynamic complications were recorded. Stage 2: Literature search to develop evidence based guidelines for blood transfusion.

The data in stage 1 was evaluated in the light of those guidelines to determine appropriateness of blood transfusion. Stage 3: Dissemination and implementation of guidelines. Anaesthetic, Orthopaedic and audit departments were involved. Guidelines were presented, discussed, finalised and circulated.

Stage 4: Prospective re-evaluation of blood transfusion practice was undertaken. Parameters as in stage 1 plus documentation of reason for blood transfusion by the prescriber were recorded.

For stage 1, 97 Hip arthroplasty (86 primary and 11 revisions) and 119 Total knee arthroplasty procedures (109 primary and 10 revisions) over a period of 26 weeks were studied. Blood transfusion rate was 50.5% (49/97) in hip arthroplasty and 28.5% (34/119) in knee arthroplasty. Evidence based guidelines were developed. 55% transfusions were thought to be inappropriate in the light of guidelines. Following completion of stage 2 and 3, prospective audit of blood transfusion practice was initiated. It was compulsory for the person prescribing blood to document the indication. Data was collected on a daily basis for 15 weeks. In that period 150 joint replacements were undertaken. 77 hip arthroplasty (71 primary and 6 revisions) and 73 knee arthroplasty procedures (66 primary and 7 revisions) were undertaken. Blood transfusion rates for hip arthroplasty decreased to 18% (14/77) and for knee arthroplasty to 5.4% (4/73).

Overall transfusion rates decreased from 83/216 (38.5%) to 18/150 (12%) after implementation of guidelines. This represents an overall reduction of 68%.

Conclusion: A multidisciplinary approach and putting evidence based practice in place has resulted in reduced blood transfusion rates in hip and knee arthroplasty in our institution. We feel this change is an example of implementation of evidence-based practice.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 342 - 342
1 Mar 2004
Bajwa A Bajwa S Finn P Port A
Full Access

Aims: To derive a formula for blood loss estimation and also to assess if high body weight is protective against blood transfusion following elective arthroplasty? Methods: Retrospective study of patients undergoing elective primary hip arthroplasty. Weight of the patient, pre and postoperative haematological investigations and details of blood transfusion were collected. Results: Formula for blood loss estimation was derived, Blood loss= ( 70 x body weight in Kg) x (drop in haematocrit) (Pre-op haematocrit+ post-op haematocrit)Ö2

The mean blood loss in 86 patients was 1631ml. Mean blood lost/Kg body weight was 22.6ml. 36/86 patients had < 21ml/kg (42%) and 50/86 had > 21ml/kg blood loss (58%). 21 ml/kg represents 30% loss of blood volume. Patients losing > 21ml/kg blood had signiþcantly higher blood transfusion rates (Chi squared test; χ2(1)= 5.50, p=0.02).

The amount of blood loss increases with weight of patients (p< 0.01). The rates of transfusion in patients with ≤ 72 kg weight (circulatory volume ~ 5 litre) was 51% (23/45), and in patients > 72 kg it was 36.5% (15/41). Rates of transfusion were related to pre-op Hb but were unaffected by gender, age, cemented/uncemented prosthesis, surgical approach, type of prosthesis, use of drains, grade of surgeon, type of anaesthetic. Conclusion: Calculated blood loss > 21ml/kg and patientñs low body weight are associated with increased risk of blood transfusion.