header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 509 - 509
1 Oct 2010
Aldinger P Aldinger G Krahmer K Omlor G Ulrich H
Full Access

Introduction: Improved biomechanics and stem fit facilitated by gender adepted dual stems and modularity has the potential to make THA easier and thereby decrease the complication rate. Increased fretting wear at the connecting interfaces may be a drawback. 10 year survival exceeding 90% is required to endorse modular necks and dual stem gender technology.

Materials and Methods: We followed the first 190 consecutive implantations of an uncemented, straight femoral stem with dual stem technology and modular necks (European Hip System (EHS)/Profemur E, Wright Medical Technology Inc., Arlington, TN, USA) and a grit blasted titanium acetabular cup with a ceramic on polyethylene bearing in 178 patients from 1992 to 1997. Mean time of follow-up evaluation was 10 (8–13) years. Titanium serum ion levels were measured to detect fretting in the metal connection.

Results: At follow-up, 21 patients (22 hips, 11.6%) had died, and 13 (14 hips, 7.4%) were lost to follow-up. One hip underwent femoral revision for a periprosthetic fracture. Overall stem survival was 99 (98–100) % at 10 years, survival with femoral revision for aseptic loosening as an end point was 100 (99–100) % at 10 years. Three acetabular components were revised, one for infection and two for aseptic loosening of the titanium shell. There was one fracture of a high offset modular neck at the laser labeling without trauma; the design was changed subsequently. The mean Harris-Hip-Score at follow-up was 88 points. 153 hips were available for radiolographic evaluation. No case of femoral or acetabular osteolysis or loosening was found. Accelerated wear was not detected on radiographs. No dislocation was found during the study period. The results showed no increased titanium serum ion levels compared to an age matched control group.

Conclusions: The complication rate with this uncemented modular gender hip system was extremely low with a high patient (and surgeon) satisfaction. The modular neck system as well as the dual stem technology proved to be reliable. The metal ion analysis revealed no elevated serum ion levels. Modular necks and dual gender stems are a reliable and durable option in primary total hip arthroplasty.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 403 - 403
1 Apr 2004
Aldinger G
Full Access

Longevity of the implants is the most respected factor in THA. Except from this fact, complications like dislocation, wear and osteolysis are reported in literature most frequently. But there is an underestimation in the orthopedic community in the importance of joint function, which is directly related to accurate restoration of joint geometry. This might be due to a lack of functional parameters for the measurement and availability of adequate implants for accurate restoration of joint geometry.

From our point of view the two problems: stable stem fixation and joint geometry have to be addressed separately: Safe stem fixation on the one hand, adequate joint geometry on the other hand. With the use of standard implants compromises have to be made on either side. To avoid this dilemma, we propose alternative systems: A modular system with interchangeable necks as a standard implant for better fit and adequate joint geometry or a custom implant. In the presentation we address the interference of stem fit and joint geometry and discuss problems and advantages of modularity and custom implants.