RHF nail is an important tool for simultaneous ankle and subtalar joint stabilisation +/− fusion. Straight and curved RHF nails are available to use, but both seem to endanger plantar structures, especially the lateral plantar artery and nerve and Baxter's nerve. There is a paucity of literature on the structures at risk with a straight RHF nail inserted along a line bisecting the heel pad and the second toe (after Stephenson et al). In this study, plantar structures ‘at risk’ were studied in relation to a straight nail inserted as above. Re-creating real-life conditions and strictly following the recommended surgical technique with regards to the incision and guide-wire placement, we inserted an Orthosolutions Oxbridge nail into the tibia across the ankle and subtalar joints in 6 cadaveric specimens. Tissue flaps were then raised to expose the heel plantar structures and studied their relation to the inserted nail.Background
Methods
Increasing expectations from arthroscopic anterior cruciate ligament (ACL) reconstructions require precise knowledge of technical details such as minimum intra-femoral tunnel graft lengths. A common belief of having ≥20mm of grafts within the femoral tunnel is backed mostly by hearsay rather than scientific proof. We examined clinico-radiological outcomes in patients with intra-femoral tunnel graft lengths <20 and ≥20mm. Primary outcomes were knee scores at 1-year. Secondarily, graft revascularization was compared using magnetic resonance imaging (MRI). We hypothesized that outcomes would be independent of intra-femoral tunnel graft lengths. This prospective, single-surgeon, cohort study was conducted at a tertiary care teaching centre between 2015–2018 after obtaining ethical clearances and consents. Eligible arthroscopic ACL reconstruction patients were sequentially divided into 2 groups based on the intra-femoral tunnel graft lengths (A: < 20 mm, n = 27; and B: ≥ 20 mm, n = 25). Exclusions were made for those > 45 years of age, with chondral and/or multi-ligamentous injuries and with systemic pathologies. All patients were postoperatively examined and scored (Lysholm and modified Cincinnati scores) at 3, 6 and 12 months. Graft vascularity was assessed by signal-to-noise quotient ratio (SNQR) using MRI. Statistical significance was set at p<0.05. Age and sex-matched patients of both groups were followed to 1 year (1 dropout in each). Mean femoral and tibial tunnel diameters (P =0.225 and 0.595) were comparable. Groups A (<20mm) and B (≥20mm) had 27 and 25 patients respectively. At 3 months, 2 group A patients and 1 group B patient had grade 1 Lachman (increased at 12 months to 4 and 3 patients respectively). Pivot shift was negative in all patients. Lysholm scores at 3 and 6 months were comparable (P3= 0.195 and P6= 0.133). At 1 year both groups showed comparable Cincinnati scores. Mean ROM was satisfactory (≥130 degrees) in all but 2 patients of each group (125–130 degrees). MRI scans at 3 months and 1 year observed anatomical tunnels in all without any complications. Femoral tunnel signals in both groups showed a fall from 3–12 months indicating onset of maturation of graft at femoral tunnel. Our hypothesis, clinical and radiological outcomes would be independent of intra-tunnel graft lengths on the femoral aspect, did therefore prove correct. Intra-femoral tunnel graft lengths of <20 mm did not compromise early clinical and functional outcomes of ACL reconstructions. There seems to be no minimum length of graft within the tunnel below which suboptimal results should be expected.
Our study evaluates financial impact to the Best Practice Tariff (BPT) of hip fracture patients on Novel Oral Anti-Coagulant (NOAC) medication. Since their approval by NICE for the prevention of stroke and systemic embolism in non-valvular atrial fibrillation, the incidence of hip fracture patients admitted to hospitals on NOAC medication (e.g. rivaroxiban, apixaban) has been increasing. BPT for hip fractures has two components: a base tariff and a conditional top-up tariff of £1,335 per patient (applied to patients of 60 years of age). For the top-up tariff, six criteria must be met, of which time-to-surgery within 36 hours is one. Our department currently recommends withholding NOAC medication and delaying surgery for at least 48 hours as per our Trust's haematology guidelines to reduce intra-operative bleeding risk. Therefore, the conditional top-up tariff cannot be claimed for these patients. A retrospective review of our Trust hip fracture patients over 60 years of age admitted during 2019 on NOAC medication using National Hip Fracture Database (NHFD).Abstract
Objectives
Method
In cerebral palsy patients, while upper limb function is acknowledged as being important, it has traditionally taken a back seat to lower limb function. This is partly due to inexperience and partly due to difficulty deciding on the best way of improving upper limb function. In Swansea since June 2008 we have been offering a multi-disciplinary service for the assessment and treatment of upper limb problems in cerebral palsy. The core team consists of a consultant orthopaedic surgeon, a consultant plastic surgeon with a special interest in CP upper limb problems, a consultant paediatric neurologist, a community paediatric physiotherapist and a community paediatric occupational therapist. Upon referral, the physiotherapist and occupational therapist carry out initial functional assessment of the patient. This is followed by a joint assessment by the whole team in a special clinic held every 3 months. If required, the child is offered surgery, botox injections or both. Further follow-up is in the special clinic until the child is suitable for follow-up in a normal clinic. We present our initial experience with this multi-disciplinary approach, the problems encountered in setting up the service and our plans for the future.
To assess the effect on knee motion of gradual femoral lengthening using an intramedullary nail, between 1994 and 2003, 27 non-achondroplastic patients had bilateral femoral lengthening using the Albizzia nail. Vigorous post-operative physiotherapy was the norm. Knee motion recorded at various stages pre and post-operatively was compared. For an average gain of 6 cm the mean flexion during lengthening was 119. By final follow-up all patients had regained pre-operative range of motion. No tenotomies or joint manipulations were required. Good knee motion can be maintained during femoral lengthening using an intramedullary lengthening device.
We conducted a study comparing the midterm outcome of the Medial Pivot knee (MP) to the Posterior Stabilised (PS) knee.
Vast amount of literature is available on mechanical properties of PMMA, but not about the composite specimens of old and new cement. This is important, as in cement revision has become established technique with good clinical results. Originally Greenwald and later Li described properties of such specimens. However in these studies the old samples were only few days old, unlike clinical situation, where the old cement is a few years old. We therefore decided to test short-term mechanical properties of composite specimens and compare these with new uniform specimens. We choose specimens of cement 3–17 years old (median 11.8) for the manufacturing of the composite specimens.
The aim of this study was to evaluate whether using a predetermined entry point and standard value for valgus cut could restore normal mechanical axis of the TKA. The study included 125 consecutive patients, who underwent TKA under care of the senior author (NJD). Details of height, weight, BMI were noted. All the radiographs were taken with the patient standing, with the knees in maximum extension, with the patella facing forward. The long leg radiographs were evaluated and the mechanical axis and anatomical axis were marked. The entry point (EP) and the angle between the anatomical and the mechanical axis of the femur ware measured, which is valgus angle of distal femoral cut (VA). Statistical analysis was done using SPSS (Table 1). Proportion of the cases with VA less than 6 degrees or more than 7 degrees were identified. Similarly cases with EP distance less than 0 and more than 5mms were also identified. Cases with VA of 6–7 degrees and EP 0–5mms were identified as one group. Correlation was performed using nonparametric tests. The results revealed the angle between the anatomical and the mechanical axis ranges from 4 to 9.5 degrees (mean 6.8 degree and standard deviation 1.11 degree). Only 53% had an angle of between 6 and 7 degrees, with 7% of knees having an angle of less than 5 degree or greater than 8 degrees. The site of entry of the jig showed variation from 30mms medial to the centre to 18mms lateral to the centre with the mean entry point of 5.04mms medial to centre of the notch, with a standard deviation of 8.5mms. Overall only 33% of the knees templated would have an optimal femoral jig placement and distal femoral angle cut with an entry point in the centre of the notch or up to 5mms medial to centre and a distal valgus cut of between 6 and 7 degrees. The author feel this study gives evidence that if the mechanical axis is to be restored then long leg pre-operative radiographs should be performed and used as a key component to the pre-operative plan.
Stem dissociation in modular revision knee replacement due to failure of the frictional lock of the Morse taper has been reported in the literature. However, the medium and long-term implications of stem dissociation are unknown, as clinical outcomes have not been reported. We report a series of 10 cases in which there was intra-operative dissociation of the tibial stem. Between 1994 and 1999, 98 patients underwent revision total knee replacement for aseptic loosening at our institution. Ten of these patients were noted to have tibial stem dissociation, apparent on the immediate post-operative radiographs. The senior author (RWP) performed all procedures and used a standardized operative technique. The Co-ordinate modular knee revision system was used in all cases. The quality of the bone was noted in all the cases intra-operatively; and was graded as 1) sound bone, 2) soft but intact, 3) soft and fractured cortex. Our study demonstrates that the tibial stem dissociation did not cause any significant detriment to the clinical outcome on minimum follow-up of six years in nine cases where the tibial metaphyseal cortical rim was intact. In one case, where the medial tibial plateau had a cortical defect, the prosthesis drifted into varus mal-alignment and the patient required a further revision for aseptic loosening. We therefore question whether long canal filling tibial stems are necessary in all revision total knee replacements particularly when the cortical rim is intact and a non-constrained poly-ethylene insert is used.