The
Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented
Objectives. The objective of this study was to assess all evidence comparing the
Implant choice was changed from cemented
Thumb Carpometacarpal (CMC) arthritis is a common pathology of the hand. Surgical treatment with thumb reconstruction is well described. Retrospective outcomes have been described for multiple techniques, suggesting patient satisfaction with multiple different techniques. The
To determine if any notable differences between a cemented
Objective. To evaluate the volume of cases, causes of failure, complications in patients with a failed
Recent National Institute for Health and Care Excellence (NICE) guidance has advised against the continued use of the
Hip fractures are injuries that affect not only the joint of an elderly person, but also the patient’s survival. Four surgical options are well supported in the orthopaedic literature: reduction with internal fixation, different types of unipolar hemiarthroplasty, bipolar hemiarthroplasty, and total hip arthroplasty. The aim of this study is to assess
Aims. This study aimed to compare the change in health-related quality
of life of patients receiving a traditional cemented monoblock Thompson
hemiarthroplasty compared with a modern cemented modular polished-taper
stemmed hemiarthroplasty for displaced intracapsular hip fractures. Patients and Methods. This was a pragmatic, multicentre, multisurgeon, two-arm, parallel
group, randomized standard-of-care controlled trial. It was embedded
within the WHiTE Comprehensive Cohort Study. The sample size was
964 patients. The setting was five National Health Service Trauma
Hospitals in England. A total of 964 patients over 60 years of age who
required hemiarthroplasty of the hip between February 2015 and March
2016 were included. A standardized measure of health outcome, the
EuroQol (EQ-5D-5L) questionnaire, was carried out on admission and
at four months following the operation. Results. Of the 964 patients enrolled, 482 died or were lost to follow-up
(50%). No significant differences were noted in EQ-5D between groups,
with a mean difference at four months of 0.037 in favour of the
Exeter/Unitrax implant (95% confidence interval (CI) 0.014 to 0.087,
p = 0.156), rising to 0.045 (95% CI 0.007 to 0.098, p = 0.09) when
patients who died were excluded. The minimum clinically important
difference for EQ-5D-5L used in this study is 0.08, therefore any
benefit between implants is unlikely to be noticeable to the patient.
There was no difference in mortality or mobility score. Conclusion. Allowing for the high rate of loss to follow-up, the use of the
traditional
The carpometacarpal joint of the thumb is one of the most common locations of degenerative arthritis. Surgical options include trapezio-metacarpal fusion, replacement or resection arthroplasty with or without interposition. We report the medium term results of a Modified
We have performed a prospective review of 590 consecutive patients treated for a displaced intracapsular femoral neck fracture with a
Recent NICE guidelines have suggested abandoning the
Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes. This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.Background
Design
Introduction. Dislocated hip hemiarthroplasties (HA) are associated with a 45% revision rate and 40% mortality rate. Implant selection for HA operations vary with no universally accepted implant choice. The WHiTE3 trial suggested older designs such as the
Purpose of study and background. Clinical researchers use Pfirrmann classification for grading intervertebral disc degeneration radiologically. Basic researchers have access to morphology and instead use the
Introduction. Low back pain (LBP) is a worldwide leading cause of disability. This preclinical study evaluated the safety of a combined advanced therapy medicinal product developed during the European iPSpine project (#825925) consisting of mesendoderm progenitor cells (MEPC), derived from human induced pluripotent stem cells, in combination with a synthetic poly(N-isopropylacrylamide) hydrogel (NPgel) in an ovine intervertebral disc degeneration (IDD) model. Method. IDD was induced through nucleotomy in 4 adult sheep, 5 lumbar discs each (n=20). After 5 weeks, 3 alternating discs were treated with NPgel (n=6) or NPgel+MEPC (n=6). Before sacrifice, animals were subjected to: MRI of lumbar spines (disc height and Pfirmann grading); blood sampling (hematological, biochemical, metabolic and lymphocyte/monocytes immunological). After 3 months the sheep were sacrificed. The spines were processed for: macroscopic morphology (Thompson grading), microscopic morphology (Histological grading), and glycosaminoglycan content (GAG, DMMB Assay). Furthermore, at sacrifice biodistribution of human MEPC was assessed by Alu-sequences quantification (qPCR) from three tissue samples of heart, liver, spleen, brain, lungs, and kidneys, and PBMCs collected to assess activation of systemic immune cells. To each evaluation, appropriate statistical analysis was applied. Result. Flow cytometry showed no induction of systemic activation of T cells or monocytes. Alu quantification did not give detection of any cells in any organ. Disc height index was slightly increased in discs treated with NPgel+MEPC. Pfirmann's and
Degenerative disc disease (DDD) is a common cause of lower back pain. Calcification of the intervertebral disc (IVD) has been correlated with DDD, and is especially prevalent in scoliotic discs. The appearance of calcium deposits has been shown to increase with age, and its occurrence has been associated with several other disorders such as hyperparathyroidism, chondrocalcinosis, and arthritis. Trauma, vertebral fusion and infection have also been shown to increase the incidence of IVD calcification. Our data indicate that Ca. 2+. and expression of the extracellular calcium-sensing receptor (CaSR) are significantly increased in mild to severely degenerative human IVDs. In this study, we evaluated the effects of Ca. 2+. and CaSR on the degeneration and calcification of IVDs. Human donor lumbar spines of
Current evidence suggests that we should be moving away from
Current evidence suggests that we should be moving away from