Background: Recent studies of arthroscopic rotator cuff repairs have shown high failure. The different suture configurations were mostly tested in non degenerative animal tendon specimen. We used instead fresh-frozen degenerative human cadaver
Rotator cuff tears are the most common cause of shoulder disability, affecting 10% of the population under 60 and 40% of those aged 70 and above. Massive irreparable rotator cuff tears account for 30% of all tears and their management continues to be an orthopaedic challenge. Traditional surgical techniques, that is, tendon transfers are performed to restore shoulder motion, however, they result in varying outcomes of stability and complications. Superior capsular reconstruction (SCR) is a novel technique that has shown promise in restoring shoulder function, albeit in limited studies. To date, there has been no biomechanical comparison between these techniques. This study aims to compare three surgical techniques (SCR, latissimus dorsi tendon transfer and lower trapezius tendon transfer) for irreparable rotator cuff tears with respect to intact cuff control using a clinically relevant biomechanical outcome of rotational motion. Eight fresh-frozen shoulder specimens with intact
The purpose of this diagnostic, cross-sectional study, was to determine the predictive value of clinical examination versus ultrasonographic evaluation in rheumatoid arthritis patients, suspected of having rotator cuff disease. The left and right shoulders of fifty consecutive patients from the rheumatoid clinic were subjected to clinical examination by a senior registrar in the department. Impingement was evaluated using the Neer, Hawkins and posterior impingement tests. The supra-spinatus tendon insertion (Jobe test), infraspinatusteres minor tendon insertions (resisted external rotation) and subscapularis tendon insertion (Gerber lift-off and push-off tests) into the rotator cuff were evaluated for a possible tear. A Professional Sport Sonographer, located in a separate examination room then performed an ultrasonographic evaluation on all of the patients. The clinical results were compared to the ultrasound results, hoping to find a method that will improve our current screening of rheumatoid patients for rotator cuff disease and planning of possible surgical treatment. A significant difference was found between the clinical and sonographic evaluation of the
Two dimensional ultrasound of the shoulder joint has become a well established diagnostic tool. Difficult interpretation of ultrasonographic findings, however, suggests that ultrasound appears not to be an always reliable method, especially in partial thickness tears. The present study was performed to determine whether the use of three dimensional (3D) sonography further increases the diagnostic yield of ultrasound. On a total of 22 externally intact appearing
Aim: Revision of shoulder replacements in patients with irreparably damaged
Purpose of the study: The aim of this biomechanical study was to assess the performance of the deltoid muscle in the absence of a rotator cuff using different models for shoulder prosthesis. Material and methods: A computer model reproducing the three dimensions of the glenohumeral joint was use to analyze the force of the deltoid muscle during abduction movements in shoulders devoid of a rotator cuff. The three heads of the deltoid were analyzed in order to determine the most effective level of muscle tension. The lever arm of the deltoid was measured from 0–90° abduction. Using this 3D model, we simulated implantation of six different models of reversed prostheses in order to assess the biomechanical situation which would be the most favorable for the deltoid. Performance of the normal deltoid was compared with the performance of the deltoid after implantation of an anatomic prosthesis and after implantation of an reversed prosthesis. Several variables were studied: medial offset of the center of rotation, lateral offset of the humerus, lengthening of the deltoid muscle. Results: Optimal deltoid performance (especially from 60–90° abduction) was observed if the center of rotation was offset medially and the humerus was offset laterally and lowered. A 10% increase in the length of the muscle fibres increased muscle performance 18%. Exaggerated lateral offest of the humerus increased deltoid performance between 30 and 60° abduction but lost its beneficial effect at 90° abduction. From 15° abduction, a scapular notch appeared when the humerus was off set medially. This could be avoided if the humerus was offset laterally with a less medial center of rotation. Beyond 150° abduction, superior impingement appeared irrespective of the type of prosthesis. Discussion and conclusion: This biomechanical study proved the superiority of reversed prostheses compared with anatomic prostheses for massive rotator cuff tears. Medial offset of the center of rotation reduced shear forces on the glenoid. Lateral offset of the humerus increase via a pulley effect the lowering force of the deltoid. Lowering the humerus pulled on the muscle fibers of the deltoid and increased their performance. Dosing these three variables with an appropriate («ideal») design for the reversed prosthesis would optimize deltoid performance in patients with deficient
Purpose: Determine the ideal form of subacromial decompression. Method: Six cadaveric shoulders with intact
Purpose of the study: The aim of this study was to evaluate the anatomical and technical limits of endoscopic rotator cuff repair. Anatomical results were also compared with functional assessment of the shoulder. Material and methods: A multicentric serie of 87 patients presenting a full thickness rotator cuff tear repaired endoscopically was retrospectively reviewed at 25.4 months (mean) post surgery. Limits of the surgical technique were studied in correlation with functional results and anatomic radiographic evaluation (arthroscans in 93 p. 100). Results: Anatomical repair (normal thickness and no contrast in the subacromial space on arthroscan) was achieved in 83 p. 100 of the
Aim: To assess the outcome of arthroscopic subacromial decompression on rotator cuff muscles. Material: 44 patients with impingement syndrome and intact
Purpose: There is still debate on classification, pathogenesis, and treatment of partial non-full thickness tears of the rotator cuff. We assessed mid-term outcome after arthroscopic repair. Material and methods: Between 1990 and 1998, 208 partial tears of the
Aim: To investigate the effect of Arthroscopic Subacromial Decompression and rehabilitation on rotator cuff muscle strength and function. Material: 24 patients with primary impingement syndrome and intact
Orthopaedic surgery requires grafts with sufficient mechanical strength. For this purpose, decellularized tissue is an available option that lacks the complications of autologous tissue. However, it is not widely used in orthopaedic surgeries. This study investigated clinical trials of the use of decellularized tissue grafts in orthopaedic surgery. Using the ClinicalTrials.gov (CTG) and the International Clinical Trials Registry Platform (ICTRP) databases, we comprehensively surveyed clinical trials of decellularized tissue use in orthopaedic surgeries registered before 1 September 2022. We evaluated the clinical results, tissue processing methods, and commercial availability of the identified products using academic literature databases and manufacturers’ websites.Aims
Methods
Rotator cuff disease (RCD) can considerably decrease quality of life. Here, we investigated whether health-related quality of life (HRQoL) influences the need for surgery in patients with RCD. We performed an analysis of 417 patients with symptomatic RCD who were recruited from two hospitals between June 2008 and December 2014 to be randomized to receive non-surgical or surgical treatment. After a three-month rehabilitation period, 36-Item Short-Form Health Survey questionnaire (SF-36), shoulder pain (visual analogue scale (VAS)), and shoulder function (Constant-Murley score) data were available from 191 still-symptomatic patients who were eligible for surgery. A control group was formed from 87 excluded patients who were no longer eligible for surgery due to relief of symptoms.Aims
Methods
Rotator cuff muscle atrophy and fatty infiltration affect the clinical outcomes of rotator cuff tear patients. However, there is no effective treatment for fatty infiltration at this time. High-intensity interval training (HIIT) helps to activate beige adipose tissue. The goal of this study was to test the role of HIIT in improving muscle quality in a rotator cuff tear model via the β3 adrenergic receptor (β3AR). Three-month-old C57BL/6 J mice underwent a unilateral rotator cuff injury procedure. Mice were forced to run on a treadmill with the HIIT programme during the first to sixth weeks or seventh to 12th weeks after tendon tear surgery. To study the role of β3AR, SR59230A, a selective β3AR antagonist, was administered to mice ten minutes before each exercise through intraperitoneal injection. Supraspinatus muscle, interscapular brown fat, and inguinal subcutaneous white fat were harvested at the end of the 12th week after tendon tear and analyzed biomechanically, histologically, and biochemically.Aims
Methods
Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).Objectives
Methods
Many biomechanical studies have shown that the weakest biomechanical point of a rotator cuff repair is the suture-tendon interface at the medial row. We developed a novel double rip-stop (DRS) technique to enhance the strength at the medial row for rotator cuff repair. The objective of this study was to evaluate the biomechanical properties of the DRS technique with the conventional suture-bridge (SB) technique and to evaluate the biomechanical performance of the DRS technique with medial row knots. A total of 24 fresh-frozen porcine shoulders were used. The infraspinatus tendons were sharply dissected and randomly repaired by one of three techniques: SB repair (SB group), DRS repair (DRS group), and DRS with medial row knots repair (DRSK group). Specimens were tested to failure. In addition, 3 mm gap formation was measured and ultimate failure load, stiffness, and failure modes were recorded.Aims
Methods
The April 2012 Shoulder &
Elbow Roundup360 looks at katakori in Japan, frozen shoulder, if shoulder impingement actually exists, shoulder arthroscopy and suprascapular nerve blocks, why shoulder replacements fail, the infected elbow replacement, the four-part fracture, the acromion index, and arm transplantation
To investigate the appropriate dose and interval for the administration
of triamcinolone acetonide (TA) in treating tendinopathy to avoid
adverse effects such as tendon degeneration and rupture. Human rotator cuff-derived cells were cultured using three media:
regular medium (control), regular medium with 0.1 mg/mL of TA (low
TA group), and with 1.0 mg/mL of TA (high TA group). The cell morphology,
apoptosis, and viability were assessed at designated time points.Objectives
Methods
The June 2012 Shoulder &
Elbow Roundup360 looks at: reverse shoulder replacement; torn rotator cuffs and platelet-rich fibrin; rotator cuff repair; frozen shoulder; whether an arthroscopic rotator cuff repair actually heals; the torn rotator cuff’s effect on activities of daily living; subacromial impingement; how to improve the reliability of the Constant-Murley score; and failure of the Neer modification of an open Bankart procedure.