SARS-CoV-2 emerged in Wuhan, China in December 2019 causing pneumonia and resulting in a pandemic, commonly known as COVID-19. This pandemic led to significant changes to our daily lives due to restrictions, such as social distancing, quarantining, stay at home orders and closure of restaurants and shops among other things. The psychological effects of this uncertainty as well as of these changes to our lives have been shown to be significant. This study is a
Purpose of Study and Background. Degenerative cervical myelopathy resulting in cord compromise is a progressive condition that results in significant quality of life limitations. Surgical treatment options available are anterior and/or posterior decompression of the affected levels. Patients are counselled pre-operatively that the aim of surgical intervention is to help prevent deterioration of neurology. Anecdotal evidence suggested improvements in both EMS and PROMs in this cohort of patients. A 2-year
Introduction. Polyacrylamide hydrogel (iPAAG. 1. ), is CE marked for treating symptomatic knee osteoarthritis (OA), meeting the need for an effective, long-lasting, and safe non-surgical option. This study evaluates the efficacy and safety of a single 6 ml intra-articular injection of iPAAG in participants with moderate to severe knee OA over a 5-year post-treatment period, presenting data from the 4-year follow up. Method. This
Adverse spinopelvic characteristics (ASC) have been associated with increased dislocation risk following primary total hip arthroplasty (THA). A stiff lumbar spine, a large posterior standing tilt when standing and severe sagittal spinal deformity have been identified as key risk factors for instability. It has been reported that the rate of dislocation in patients with such ASC may be increased and some authors have recommended the use of dual mobility bearings or robotics to reduce instability to within acceptable rates (<2%). The aims of the
Pathologies such as Scapho-Lunate Advanced Collapse (SLAC), Scaphoid Non-union Advanced Collapse (SNAC) and Kienbock's disease can lead to arthritis in the wrist. Depending on the articular surfaces that are involved, motion preserving surgical procedures can be performed. Proximal Row Carpectomy (PRC) and Four Corner Fusion (4CF) are tried and tested surgical options. However,
Aims. The primary aim of this
Objectives. Total hip arthroplasty (THA) is one of the most successful surgical procedures; several bearing technologies have been used, however none of these is optimal. Metal on polycarbonate-urethane (PCU) is a new bearing technology with several potential advantages: PCU is a hydrophilic soft pliable implant quite similar in elasticity to human cartilage, offers biostability, high resistance to hydrolysis, oxidation, and calcification, no biodegradation, low wear rate and high corrosion resistance and can be coupled with large metal heads (Tribofit Hip System, THS). The aim of this
This study was proposed to evaluate the efficacy of fibrin clot augmentation in meniscal tear using inside-out meniscal repair. A total of 35 patients with meniscus tears were operated on with inside-out meniscus repair and fibrin clot augmentation. Patients were evaluated preoperatively and postoperatively with clinical criteria, Lysholm knee scoring system, and MRI. Out of the total 35 cases, 5 cases were lost to follow up. Clinical improvement was observed in 29 out of 30 patients (96.6%). The mean Lysholm score improved significantly from 67.63 ± 6.55 points preoperatively to 92.0 ± 2.9 points postoperatively (P < 0.05) in 2 years follow-up. Follow-up MRI in all patients revealed complete healing except in 1 case where the patient presented with recurrence of symptoms such as pain and locking which resolved with partial meniscectomy. Paraesthesia in the anterior part of the knee was observed in 2 cases. (6.6%). We conclude that fibrin clot augmentation is a good cost-effective modality of treatment for repairable meniscus tears to preserve the meniscus and decrease the point contact pressure on the condyles which may prevent the early occurrence of osteoarthritis.
A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in an MHRA-approved clinical investigation to provide a non metallic alternative hip resurfacing product. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures both before and 12 months following surgery in comparison with age and gender matched healthy controls. Eighty-two unilateral cHRA patients consented to this study as part of a larger prospective, non-randomised, clinical investigation. In addition to their patient reported outcome measures (PROMs), self- reported measures of physical activity levels and gait analysis were undertaken both pre- operatively (1.5 weeks) and post operatively (52 weeks). This data was then compared to data from a group of 43 age gender and BMI matched group of healthy controls. Kinetics and kinematics were recorded using an instrumented treadmill and 3D Motion Capture. Statistical parametric mapping was used for analysis. cHRA improved the median Harris Hip Score from 63 to 100, Oxford Hip score from 27 to 48 and the MET from 5.7 to 10.3. cHRA improved top walking speed (5.75km vs 7.27km/hr), achieved a more symmetrical ground reaction force profile, (Symmetry Index value: 10.6% vs 0.9%) and increased hip range of motion (ROM) (31.7° vs 45.9°). Postoperative data was not statistically distinguishable from the healthy controls in any domain. This gait study sought to document the function of a novel ceramic hip resurfacing, using those features of gait commonly used to describe the shortcomings of hip arthroplasty. These features were captured before and 12 months following surgery. Preoperatively the gait patterns were typical for OA patients, while at 1 year postoperatively, this selected group of patients had gait patterns that were hard to distinguish from healthy controls despite an extended posterior approach. Applications for regulatory approval have been submitted.
Aim. Cutibacterium acnes (C. acnes) is the most cultured organism implicated in periprosthetic shoulder infections. Nevertheless, the clinical significance of its persistence on the skin surface and in the deep layers during shoulder arthroplasty surgery remains still unknown. The purpose of this study was to know if the C. acnes isolate present in deep tissues at the end of a primary shoulder arthroplasty could be responsible for shoulder arthroplasty infection. Method.
Fracture neck of femur is aptly called as “the fracture of necessity” owing to the various factors responsible for its non-union. Pauwel's inter-trochantric valgus osteotomy is a useful approach to deal with such fractures. The aim of this study is to evaluate the functional outcome of valgus osteotomy in treatment of neglected and non-union fracture neck of femur using Harris Hip Scoring system (HHS).Abstract
INTRODUCTION
AIM
Charcot neuroarthropathy is a destructive disease characterized by progressive bony fragmentation as a result of the isolated or accumulative trauma in patients with decreased sensation that manifests as dislocation, periarticular fractures and instability. Although amputation can be a reasonable cost economic solution, many patients are willing to avoid that if possible. We explored here one of the salvage procedures. 23 patients with infected ulcerated unstable Charcot neuroarthropathy of the ankle were treated between 2012 and 2017. The mean age was 63.5 ±7.9 years; 16 males and 7 females. Aggressive open debridement of ulcers and joint surfaces, with talectomy in some cases, were performed followed by external fixation with an Ilizarov frame. The primary outcome was a stable plantigrade infection free foot and ankle that allows weight bearing in accommodative foot wear.Background
Methods
The prevalence of gluteal tendinopathy (GT) associated with osteoarthritis of the hip is difficult to determine as it is frequently undiagnosed or misdiagnosed as trochanteric bursitis. Its relationship to total hip arthroplasty (THA) outcomes is currently unknown. The aim of this study was to determine the incidence of GT at the time of hip arthroplasty and examine the relationship between GT and patient reported outcomes (PROMS) before and after THA. Patients undergoing THA for primary osteoarthritis between August 2017 and August 2020 were recruited. Tendinopathy was assessed and graded at time of surgery. PROMS included the Oxford Hip Score (OHS), HOOS JR, EQ-5D, and were collected preoperatively and at one year after THA. Satisfaction with surgery was also assessed at 1 year. 797 patients met eligibility criteria and were graded as Grade 1: normal tendons (n =496, 62%), Grade 2: gluteal tendinopathy but no tear (n=222, 28%), Grade 3: partial/full thickness tears or bare trochanter (n=79, 10%). Patients with abnormal gluteal tendons were older (p=0.001), had a higher mean BMI (p=0.01), and were predominately female (p=0.001). Patients with higher grade tendinopathy had statistically significant inferior PROMS at one year, OHS score (44.1 v 42.9 v 41.3, p 0.001) HOOS JR (89.3 V 86.3 V 85.6 p 0.005). Increasing gluteal tendon grade was associated with a greater incidence of problems with mobility (p=0.001), usual activities (p=0.001) and pain (p=0.021) on EQ5D. There was a 3 times relative risk of overall dissatisfaction with THA in the presence of gluteal tears. This study demonstrated that gluteal tendinopathy was commonly observed and associated with inferior 1-year PROMS in patients undergoing THA for OA. Increasing degree of tendinopathy was a negative prognostic factor for worse functional outcomes and patient satisfaction.
Background/Purpose. Patient-specific design (PSD) total knee arthroplasty (TKA) implants are marketed to restore neutral mechanical axis alignment (MAA) and provide better anatomic fit compared to standard off-the-shelf (OTS) TKA designs. The purpose of this study was to compare the Knee-Society scores, radiographic outcomes, and complications of PSD and OTS implants. Methods. IRB approved
Aims. The aim of this study was to compare the preinjury functional scores with the postinjury preoperative score and postoperative outcome scores following anterior cruciate ligament (ACL) reconstruction surgery (ACLR). Methods. We performed a
To explore the relationship in terms of time scale between pre-operative expectations and postoperative outcomes and satisfaction after Hallux valgus surgery. A patient derived questionnaire was developed and 30 patients aged 19 to 67 were included undergoing primary hallux valgus correction with a first metatarsal osteotomy and distal soft tissue release. Patients were asked pre-operatively to quantify their expected time scale for improvement in pain, ability to walk unaided, ability to drive, routine foot wear and foot feeling normal at 6 weeks, 3 and 6 months following surgery, and to indicate their confidence in achieving this result. Patients recorded postoperative outcomes achieved at number of weeks. Ordinal logistic regression multivariate modelling was used to examine predictors of postoperative satisfaction.Purpose
Methods
The optimum indications for debridement, antibiotics and implant retention (DAIR) are unclear. Previous studies have demonstrated higher success rate of DAIR within one year of the primary arthroplasty. This study aimed to compare the success rate of DAIR vs revision in “early” and “late” infections to provide guidance for clinical decision making. The Prosthetic Joint Infection in Australia and New Zealand Observational (PIANO) cohort prospectively recorded PJIs between July 2014 and December 2017 in 27 hospitals. This study included PIANO patients with first time PJIs occurring after primary TKA. Treatment success was defined as the patient being alive, free from further revision and without clinical or microbiological evidence of reinfection at two years follow-up. “Early” and “late” infections were analyzed separately. Univariate analysis compared demographic and disease specific factors between the DAIR and Revision groups. Multivariate binary logistic regression identified whether treatment strategy and other risk factors were associated with treatment success in “early” and “late” infections. In 117 “early” (<1 year) infections, treatment success rate was 56% in the DAIR group and 54% in the revision group (p=0.878). No independent risk factors were associated with treatment outcome on multivariate analysis. In 134 “late” (>1 year) infections, treatment success rate was 34.4% in the DAIR group and 60.5% in the revision group (OR 3.07 p=0.006). On multivariate analysis, revision was associated with 2.47x higher odds of success (p=0.041) when compared to DAIR, patients with at least one significant co-morbidity (OR 2.27, p=0.045) or with Staphylococcus aureus PJIs (OR 2.5, p=0.042) had higher odds of failure. In “late” PJIs occurring >1 year following primary TKA, treatment strategy with revision rather than DAIR was associated with greater success. Patients with significant comorbidities and Staphylococcus aureus PJIs were at higher risk of failure regardless of treatment strategy.
Aims. To investigate if preoperative CT improves detection of unstable trochanteric hip fractures. Methods. A single-centre
The iASSIST system is a portable, accelerometer base with electronic navigation used for total knee arthroplasty (TKA) which guides the surgeon to align and validate bone resection during the surgical procedure. The purpose of this study was to compare the radiological outcome between accelerometer base iASSIST system and the conventional system. Method. A
Aims. This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Methods. Using a life-cycle assessment approach, we conducted a