Introduction. Despite generally excellent
After anterior cruciate ligament (ACL) rupture, reconstructive surgery with a hamstring tendon autograft is often performed. Despite overall good results, ACL re-rupture occurs in up to 10% of the patient population, increasing to 30% of the cases for patients aged under 20 years. This can be related to tissue remodelling in the first months to years after surgery, which compromises the graft's mechanical strength. Resident graft fibroblasts secrete matrix metalloproteinases (MMPs), which break down the collagen I extracellular matrix. After necrosis of these fibroblasts, myofibroblasts repopulate the graft, and deposit more collagen III rather than collagen I. Eventually, the cellular and matrix properties converge towards those of the native ACL, but full restoration of the ACL properties is not achieved. It is unknown how inter-patient differences in tissue remodelling capacity contribute to ACL graft rupture risk. This research measured patient-specific tissue remodelling-related properties of human hamstring tendon-derived cells in an in vitro micro-tissue platform, in order to identify potential biological predictors for graft rupture. Human hamstring tendon-derived cells were obtained from remnant autograft tissue after ACL reconstructions. These cells were seeded in collagen I gels on a micro-tissue platform to assess inter-patient cellular differences in tissue remodelling capacity. Remodelling was induced by removing the outermost micro-posts, and micro-tissue compaction over time was assessed using transmitted light microscopy. Protein expression of tendon marker tenomodulin and myofibroblast marker α-smooth muscle actin (αSMA) were measured using Western blot. Expression and activity of remodelling marker MMP2 were determined using gelatin zymography. Cells were obtained from 12 patients (aged 12–51 years). Patient-specific variations in micro-tissue compaction speed or magnitude were observed. Up to 50-fold differences in αSMA expression were found between patients, although these did not correlate with faster or stronger compaction. Surprisingly, tenomodulin was only detected in samples obtained from two patients. Total MMP2 expression varied between patients, but no large differences in active fractions were found. No correlation of patient age with any of the remodelling-related factors was detected. Remodelling-related biological differences between patient tendon-derived cells could be assessed with the presented micro-tissue platform, and did not correlate with age. This demonstrates the need to compare this biological variation in vitro - especially cells with extreme properties - to clinical outcome. Sample size is currently increased, and
The ability to predict which patients will improve following routine surgeries aimed at preventing the progression of osteoarthritis is needed to aid patients being stratified to receive the most appropriate treatment. This study aimed to investigate the potential of a panel of biomarkers for predicting (prior to treatment) the clinical outcome following treatment with microfracture or osteotomy. Proteins known to relate to OA severity, with predictive value in autologous cell implantation treatment or that had been identified in proteomic analyses (aggrecanase-1/ ADAMTS-4, cartilage oligomeric matrix protein (COMP), hyaluronic acid (HA), Lymphatic Vessel Endothelial Hyaluronan Receptor-1, matrix metalloproteinases-1 and −3, soluble CD14, S100 calcium binding protein A13 and 14-3-3 protein theta) were assessed in the synovial fluid (SF) of 19 and 13 patients prior to microfracture or osteotomy, respectively, using commercial immunoassays. Levels of COMP and HA were measured in the plasma of these patients. To find predictors of postoperative function, multiple linear regression analyses were performed.Abstract
Objectives
Methods
Introduction. Variation in resection thickness of the femur in Total Knee Arthroplasty (TKA) impacts the flexion and extension tightness of the knee. Less well investigated is how variation in patient anatomy drives flexion or extension tightness pre- and post- operatively. Extension and flexion stability of the post TKA knee is a function of the tension in the ligaments which is proportional to the strain. This study sought to investigate how femoral ligament offset relates to post-operative navigation kinematics and how outcomes are affected by component position in relation to ligament attachment sites. Method. A database of TKA patients operated on by two surgeons from 1-Jan-2014 who had a pre-operative CT scan were assessed. Bone density of the CT scan was used to determine the medial and lateral collateral attachments. Navigation (OmniNav, Raynham, MA) was used in all surgeries, laxity data from the navigation unit was paired to the CT scan. 12-month postoperative Knee Osteoarthritis and Outcome Score (KOOS) score and a postoperative CT scan were taken. Preoperative segmented bones and implants were registered to the postoperative scan to determine change in anatomy. Epicondylar offsets from the distal and posterior condyles (of the native knee and implanted components), resections, maximal flexion and extension of the knee and coronal plane laxity were assessed. Relationships between these measurements were determined. Surgical technique was a mix of mechanical gap balancing and kinematically aligned knees using Omni (Raynham, MA) Apex implants. Results. 119 patients were identified in the database. 60% (71) were female and the average age was 69.0 years (+/− 8.1). The average distal femoral bone resection was 7.5 mm (+/− 1.6) medially and 5.4 mm (+/− 2.1) laterally, and posterior 10.2 mm (+/− 1.7) medially and 8.4 mm (+/− 1.8) laterally, with implant replacement thicknesses 9 mm distally and 11 mm posterior. Maximum flexion of the knee post implantation was 121.5° (+/− 8.1) from a preoperative value of 117.9° (+/− 9.5). Change in the collateral ligament offsets brought on by surgery had significant correlations with several laxity and flexion measures. Increase in the posterior offset of the medial collateral attachment brought on by surgery was shown to decrease the maximum flexion attained (coefficient = −0.53, p < 0.001), Figure 1. Increased distal medial offset post-operatively compared to the posterior offset is significantly correlated with improved KOOS pain outcomes (coefficient = 0.23, p = 0.01). Similarly, a decrease in the distal offset of the lateral collateral ligament increased the coronal plane laxity in extension (coefficient = 0.37, p < 0.001), while the posterior lateral resection was observed to correlate with postoperative coronal laxity in flexion (coefficient = 0.42, p < 0.001). Conclusions. Accounting for variation in ligament offset during surgically planning may improve balancing outcomes. Although new alignment approaches, such as kinematic alignment, have been able to demonstrate improvements in short term outcomes, elimination of postoperative dissatisfaction has not been achieved. The interaction of an alignment strategy with a given patient's specific anatomy may be the key to unlocking further TKA
Acute distal biceps tendon repair reduces fatigue-related pain and minimises loss of forearm supination and elbow flexion strength. We report the short- and long-term outcome following repair using an EndoButton technique. Between 2010 – 2018, 102 patients (101 males; mean age 43 years) underwent acute (□6 weeks) distal biceps tendon repair using an EndoButton technique. The primary short-term outcome was complications. The primary long-term outcome was the Quick-DASH (Q-DASH). Secondary outcomes included the Oxford Elbow Score (OES), EuroQol-5D-3L (EQ-5D), return to function and satisfaction. At mean short-term follow-up of 4 months (2.0 – 55.5) eight patients (7.8%) experienced a major complication and 34 patients (33.3%) experienced a minor complication. Major complications included re-rupture (n=3, 2.9%), unrecovered nerve injury (n=4, 3.9%) and surgery for heterotopic ossification excision (n=1, 1.0%). Three patients (2.9%) required surgery for a complication. Minor complications included neuropraxia (n=27, 26.5%) and superficial infection (n=7, 6.9%). At mean follow-up of 5 years (1 – 9.8) outcomes were collected from 86 patients (84.3%). The median Q-DASH, OES, EQ-5D and satisfaction scores were 1.2 (IQR 0 – 5.1), 48 (IQR, 46 – 48), 0.80 (IQR, 0.72 – 1.0) and 100/100 (IQR, 90 – 100) respectively. Most patients returned to sport (82.3%) and employment (97.6%) following surgery. Unrecovered nerve injury was associated with a poor outcome according to the Q-DASH (p< 0.001), although re-rupture and further surgery were not (p > 0.05). Acute distal biceps tendon repair using an EndoButton technique results in excellent
The purpose of this study was to demonstrate the feasibility of passively collecting objective data from a commercially available smartphone-based care management platform (sbCMP) and robotic assisted total knee arthroplasty (raTKA). Secondary data analysis was performed using de-identified data from a commercial database that collected metrics from a sbCMP combined with intraoperative data collection from raTKA. Patients were included in this analysis if they underwent unilateral raTKA between July 2020 and February 2021, and were prescribed the sbCMP (n=131). The population consisted of 76 females and 55 males, with a mean age of 64 years (range, 43 – 81). Pre-operative through six-week post-operative data included step counts from the sbCMP, as well as administration of the KOOS JR. Intraoperative data included surgical times, the hip-knee-ankle angle (HKA), and medial and lateral laxity assessments from the robotic assessment. Data are presented using descriptive statistics. Comparisons were performed using a paired samples t-test, or Wilcoxon Signed-rank test, with significance assessed at p<0.05. A minimal detectable change (MDC) in the KOOS JR score was considered ½ standard deviation of the preoperative values.Introduction
Methods
Even though primary total knee arthroplasty involves resurfacing the joint with metal and plastic it is much more of a soft tissue operation than it is a bony procedure. The idea that altering the planned bony resection by a few degrees on either the tibial or femoral side of the joint might somehow eliminate the multifactorial pain complaints and reduced patient satisfaction seen in some 20% or more of cases in reported clinical series is clearly overly optimistic. Axial alignment is important, but no more so than the level of distal femoral resection, tibial and femoral rotation, tibial resection level and downslope and femoral sagittal plane alignment. The real problem is that errors in component positioning are common, rarely made one at a time, and are made more common by greater procedural complexity. No matter the resection method (let alone the resection target!) errors are commonly linked and iterative. For example: femoral malrotation on an under-resected distal femur (in a knee with minimal arthritic wear to begin with) can contribute to corresponding tibial malrotation helped by a “floated” tibial trial on an all too often overly resected and downsloped tibial surface that has been recut to allow full extension with the under-resected femur (and now also results in AP laxity in flexion). Small changes in the alignment target will not fix this! On the other hand: Kinematic alignment individualised to the patient's anatomy as a means of reducing soft tissue imbalance and minimizing ligamentous releases is actually a reasonable objective and a laudable goal on the surface. The problem with operationalizing this widely relates to what is currently required to try and reliably achieve this goal using currently available implants and technology. In the early 1980's the proponents of “anatomic” alignment with a residual 2- to 3-degree varus tibial resection and corresponding joint obliquity were Hungerford and Krackow. This concept was widely adopted but proved to be fraught with difficulty in the hands of community based surgeons in that era due to common excessive varus tibial resection errors and resulting premature implant failures. Recent reports on kinematic alignment involve a plethora of technology combinations including pre-operative CT (or MRI) for 3D reconstruction and planning, custom jig fabrication, and navigated bony preparation or individualised bony cuts off of patient specific jigs. The goal is to allow customised resections that “estimate” original cartilage thickness and bone erosion and seek to replicate the original however native anatomy and provide better precision for bone resection. Even when successful this is often followed by placement of a standard implant not too different from those in the 80's and 90's which may well have one femoral articular “J curve” for all patents, a single patellofemoral groove design and anatomic shape for all, and that makes use of a central keel on a nonanatomic tibial design with limited sizing increments, all implanted into a patient without an ACL and not infrequently PCL deficient as well. And all of this is done with the hope of restoring the normal original knee kinematics! The frequent combination of several of the above factors clinically in a single knee may help explain some of the variability in results of kinematic alignment reported by some authors even after excluding certain pre-operative deformities (excess valgus or varus). For now mechanical alignment methods and instrumentation should remain the standard of care for routine TKA practice for most, and in complex primary cases for all.
Conventional total knee arthroplasty aims to place the joint line perpendicular to the mechanical axis resulting in an overall neutral mechanical alignment. This objective is promulgated despite the fact healthy adult populations are on average in varus with few proximal tibias being neutral to the mechanical axis. The goal of a neutral mechanical axis is based largely on historical studies and the fact that it is easier to make a neutral tibial cut with conventional jigs and the eye. In order to balance the flexion and extension gaps to accommodate a neutral tibial cut, in most patients, asymmetrical distal and posterior femoral cuts are required. The resulting position of the femoral component could be considered to be “mal-rotated” with respect to the patient's soft tissue envelope. Soft tissue releases are often required to “balance” the knee. Planning and execution of the surgery are largely based off 2-dimensional radiographs which grossly oversimplifies the concept of alignment to the coronal plane, largely ignoring what happens to the knee in 3-dimensions through range of motion and 4-dimensions with respect to gait, stair climbing, etc. Subsequently, neutral mechanical for all engenders the “looks good, feels bad” phenomenon seen in many patients that may in part drive the higher dissatisfaction rates seen in knee arthroplasty globally compared to hip arthroplasty. Additionally, because most tibias are in varus in the native state, placement of the tibial component in a neutral position results in a valgus orientated position during weight bearing post-operatively. Placing the tibial component in a varus, kinematic aligned position negates this deleterious condition and has been linked to improved outcomes in recent studies. New imaging and surgical techniques allow for the identification of patient specific alignment targets and the ability to more precisely execute the surgical plan with respect to 3-dimensional placement of the components. Long-term outcomes studies as well as more recent studies on “kinematic” positioning suggest that deviation away from a neutral mechanical target is safe with respect to survivorship and provides better function with a more “natural” feeling knee.
There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes. A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints.Aims
Methods
Introduction. Varus alignment of the femoral component in total hip arthroplasty (THA) is thought to be a risk factor for implant loosening and early revision surgery. The purpose of this study was to evaluate whether the Exeter stem tolerates varus alignment and assess if this theoretical malalignment has an influence on clinical outcomes. Methods. A total of 4126 consecutive THAs were reviewed for patients between 2006 and 2012 to allow for a minimum five-year follow-up. To determine the effects of the stem alignment on results, the hips were classified into 3 groups on the basis of stem alignment in initial postoperative anteroposterior radiographs. The alignment of the stem was defined as neutral, valgus (≥ 3° of lateral deviation), or varus (≥ 3° of medial deviation). The primary outcome was all cause revision with
Background Joint replacement remains the most effective healthcare measure in improving patient health related quality of life (HRQOL) and pain incompatible with normal daily living remains the primary indication for both hip and knee arthroplasty. Quality of life
Bone transport/limb lengthening with circular external fixation has been associated with a prolonged period of time in the frame and a significant major complication rate following frame removal. We examined the results of bone transport in fifty-one limbs using the “monorail” technique and found a dramatically improved lengthening index (24.5 days/cm. – time in frame /cm. of length gained) and an absence of refracture or angulatory deformity following fixator removal. This technique is our treatment of choice for limb lengthening/bone transport. We sought to determine
The effect of pre-operative pain, physical function, mental function and multiple patient factors on
Surgical complications are common and most of them are preventable. Up to 70 % of surgical errors originate outside theatre and recent studies have shown that pre-op checklists can reduce such problems. We hypothesized that in our institution outcomes could be improved by introducing a safety checklist. A modified multidisciplinary WHO safety checklist was introduced at our institution on the 1st March 2011. The primary focus was for elective patients admitted in all the units of the division. Prior to that all involved personnel (Consultants in Orthopaedics and Anaesthesia, Registrars in both departments, nursing staff in the wards and theatre and clerical staff) were fully oriented. To further ensure that everyone was familiar with the new checklist the whole month of March 2011 was used as a training month. We prospectively collected data from daily Mortality and Morbidity (MM) meetings by units from 1/1/2011 to 29/2/2011 (2 months). A pre-induction survey was completed by all Registrars. The same survey was given to the same registrars for comparison at the end of the 2 month implementation period in June 2011.Introduction
Method
Purpose of the study: Several series have been reported on arthroscopic treatment of anterior instability. Few authors have focused on
Purpose: Patients are often referred to tertiary care centers after unplanned excision of soft tissue sarcomas. In situations where the tumour is small and superficial, the situation can often easily be salvaged by re-excision of the tumour bed. However, if the original tumour is large, deep to fascia or directly adjacent to bone or neurovascular structures, the salvage procedure often becomes more complex and morbid. The purpose of this study is to evaluate the effect of unplanned excision of “high-risk” soft tissue sarcomas on
Pathological conditions of the hip joint may present with variable patterns of pain referral in the lower limb. Literature reports suggest that up to 35% of total hip arthroplasties are performed on patients whose primary compliant is obturator nerve referred “knee pain”. However the effect of varied pain patterns on
One hundred and four invasive Aim
Method
Developments in plate technology have increased interest in the operative fixation of Colles' fracture. The vast majority of patients are treated non-operatively, yet there are few medium or long-term outcome studies. The aim of this study was to evaluate medium-term outcome of a cohort of patients who previously received treatment in a plaster cast. 236 patients entered two previous prospective, randomised control studies comparing closed reduction techniques or plaster cast type. Both studies showed no difference in clinical or radiological outcome between groups. 43% of this cohort had a final dorsal tilt of > 10° and 44% had final radial shortening of >2mm. All patients now have a minimum follow-up of five years and 60 have died. The remaining 176 patients were contacted by post and asked to complete two validated patient-based questionnaires: a modified Patient Evaluation Measure and a quickDASH. 112 replies were received. The mean age of patients is 67 years (range 23 – 91 years). 31 patients are employed and 57 retired. 77% of patients had a quickDASH score of less than 20. 59% of patients never experience wrist pain whilst 8% of patients have daily pain. All Patient Evaluation Measures have shown a median score of 12 or less (0=excellent, 100= terrible). The best score was for pain (median 4; IQR 2-12) and the worst for grip strength (median 12; IQR 4 – 41). No radiological outcome 5 weeks after injury correlated with any outcome score, except for dorsal tilt, which correlated with difficulty with fiddly tasks (p=0.04) and carpal malalignment which correlated with interference with work (p=0.04). In conclusion, our results show a good functional outcome five years after non-operative management of Colles' fracture. A degree of malunion is acceptable and in the light of our results the economic impact of surgery must be evaluated.