Background: Chronic prosthetic joint infection is a cause of patient morbidity and can be challenging to treat. Surgeons performing revision arthroplasty of the hip and knee are confronted with a growing number of patients with extensive loss of bone stock. The use of a
From 1992 on 2008, 615/515 patients underwent primary or revisional endoprosthetic replacement of major joints. In 51 patients (31 men &
20 women) modular system MUTARS (Implantcast, Germany) has been used. The median age was 23.3 years (15 to 52 years). MUTARS
Background: Endoprosthetic reconstruction has become the gold standard of treatment after the resection of tumors around the proximal femur, however, the rate of complications linked to megaprostheses is clearly higher than with standard implants. Aim of this study was to investigate the incidence and type of complications related to modular proximal femur prostheses. Patients and Methods: By retrospective database analysis of the Vienna Tumor Registry, we evaluated the incidence of complications in 170 consecutive patients who have received a proximal femur KMFTR/GMRS at our institution between 1982 and 2007. 71 patients with an average age of 41.7 years (range 18.2–79.9 years) received the implant following the resection of a malignant bone tumor, 95 patients with an average age of 61.7 years (range 5.9–84.2 years) due to metastatic disease. The average time of follow-up was 3.5 years (SD ±4.9 years). Results: Overall patient survival at five years was 32%. For patients with metastatic disease the overall survival was 10% at five years. Patients being treated for a primary bone tumor had an overall survival of 55% at 5 years. The overall survival of the prosthesis was 90% at two years and 72% at five years. Twenty-one patients (12.65%) suffered from dislocation after a mean time of 6.5 month (range 0.3–33 months) after surgery. Out of these, nine had to be treated by open reduction. Nine patients suffered recurrent dislocation after their first event. Patients who underwent extensive pelvic reconstruction had a significantly higher dislocation rate (33.3%) compared to patients with no or standard acetabular components (11.2%). Deep infection occurred in twelve patients (7.3%) after a mean of 39 months (range 1–166 months) after surgery. Treatment of infection was one-stage revision in eight and hip disarticulation in one patient. Two patients were successfully treated by local wound revision. One patient died of septic shock four days after surgery. Re-infection occurred in three patients. Aseptic loosing occurred in 13 patients (12.8%) after a mean time of 75.6 months (range 1–223 months) after surgery. Revision surgery was necessary in 27 patients (15.8%) with a mean time to first revision of 32 months (range 0.3–116 months). Prosthetic fracture was found in two patients. Local recurrence occurred in 14 patients (8.4%). In seven patients (4.2%) amputation was necessary. Conclusion:
For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis. We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan.Aims
Methods
Introduction. Dual modular hip prostheses were introduced to optimize the individual and intra-surgical adaptation of the implant design to the native anatomics und biomechanics of the hip. The downside of a modular implant design with an additional modular interface is the potential susceptibility to fretting, crevice corrosion and wear [1–2]. The purpose of this study was to characterize the metal ion release of a modular hip implant system with different modular junctions and material combinations in consideration of the corrosive physiological environment. Methods. One design of a dual modular hip prosthesis (Ti6Al4V, Metha®, Aesculap AG, Germany) with a high offset neck adapter (CoCrMo, CCD-angle of 130°, neutral antetorsion) and a monobloc prosthesis (stem size 4) of the same implant type were used to characterize the metal ion release of modular and non-modular hip implants. Stems were embedded in PMMA with 10° adduction and 9° flexion according to ISO 7206-6 and assembled with ceramic (Biolox® delta) or CoCrMo femoral heads (XL-offset) by three light impacts with a hammer. All implant options were tested in four different test fluids: Ringer's solution, bovine calf serum and iron chloride solution (FeCl3-concentration: 10 g/L and 114 g/L). Cyclic axial sinusoidal compressive load (Fmax = 3800 N, peak load level of walking based on in vivo force measurements [3]) was applied for 10 million cycles using a servohydraulic testing machine (MTS MiniBionix 370). The test frequency was continuously varied between 15 Hz (9900 cycles) followed by 1 Hz (100 cycles). The metal ion concentration (cobalt, chromium and titanium) of the test fluids were analysed using ICP-OES and ICP-MS at intervals of 0, 5·105, 2·106 and 10·106 cycles (measuring sensitivity < 1 µg/L). Results. Due to the additional modular interface between stem and neck adapter the total metal ion release of the
The August 2015 Oncology Roundup360 looks at: Glasgow prognostic score in soft-tissue sarcoma; Denosumab in giant cell tumour; Timing, complications and radiotherapy; Pigmented villonodular synovitis and arthroscopy; PATHFx: estimating survival in pathological cancer; Prosthetic lengthening of short stumps; Chondrosarcoma and pathological fracture
The December 2013 Oncology Roundup360 looks at: Peri-articular resection fraught with complications; Navigated margins; Skeletal tumours and thromboembolism; Conditional survival in Ewing’s sarcoma; Reverse shoulders and tumour; For how long should we follow up sarcoma patients?; and already metastasised?