Aims. Research on
Aims. Hip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an anatomical and medialized hip rotation centre. Methods. Using 3D templating software in 49 CT scans of non-deformed femora, we virtually implanted: 1) small uncemented calcar-guided stems with two offset options (Optimys, Mathys), 2) uncemented straight stems with two offset options (Summit, DePuy Synthes), 3) cemented undersized stems (Exeter philosophy) with three offset options (CPT, ZimmerBiomet), and 4) cemented line-to-line stems (Kerboul philosophy) with proportional offsets (Centris, Mathys). We measured the distance between the templated and the anatomical and 5 mm medialized hip rotation centre. Results. Both rotation centres could be restored within 5 mm in 94% and 92% of cases, respectively. The cemented undersized stem performed best, combining freedom of stem positioning and a large offset range. The uncemented straight stem performed well because of its large and well-chosen offset range, and despite the need for cortical bone contact limiting stem positioning. The cemented line-to-line stem performed less well due to a small range of sizes and offsets. The uncemented calcar-guided stem performed worst, despite 24 sizes and a large and well-chosen offset range. This was attributed to the calcar curvature restricting the stem insertion depth along the femoral axis. Conclusion. In the majority of non-deformed femora, leg length, offset, and anteversion can be restored accurately with non-modular stems during 3D templating. Failure to restore
Introduction. The objective of our study was to determine the extent to which the quality of the biomechanical reconstruction when performing hip replacement influences gait performances. We aimed to answer the following questions: 1) Does the quality of restoration of
Aims. Spinopelvic characteristics influence the
Introduction and Objective. A proper restoration of
Robotic assisted surgery aims to reduce surgical errors in implant positioning and better restore native
Introduction. Natural population variation in femoral morphology results in a large range of offsets, anteversion angles and lengths. During total hip arthroplasty, accurate restoration of
Restoring native
The literature indicates that femoroacetabular impingement (FAI) patients do not return to the level of controls (CTRL) following surgery. The purpose of this study was to compare
Introduction. Golf is a recommended form of physical activity for older adults. However, clinicians have no evidence-based research regarding the demands on the hips of older adults during golf. The purpose of our in vivoobservational study was to quantify the
Over the past 15 years Anterior Approach (AA) THA has shown a dramatic increase in adoption by surgeons (over 30%) and choice by patients with a corresponding decrease in the percentage of hips performed with traditional posterior and lateral approaches. I began AA in 1996 in order to solve the classic problems of potential dislocation associated with posterior approach and potential abductor weakness associated with the lateral (Harding) approach. Surgeon education on AA began in 2013 and has accelerated since. AA is usually performed with the aid of an orthopaedic table which facilitates exposure though many cases are also performed on a standard operating table. Intraoperative image intensification has provided real-time feedback and accuracy for cup position leg length and offset and is facilitated by the supine position and a radiolucent orthopaedic table, however, AA can be performed without it. Earlier functional recovery with decreased post-operative pain is the best documented benefit of AA as well as decreased dislocation rate. My own point of view is to take advantage of a switch to AA to improve more than your surgical approach. Improve also
Background. Modularity in total hip replacement(THR) enables precise recreation of native
Cite this article:
Purpose. The ultimate goal in total hip arthroplasty is not only to relieve the pain but also to restore original
Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems. In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years.Aims
Methods
INTRODUCTION. Combining novel diverse population-based software with a clinically-demonstrated implant design is redefining total hip arthroplasty. This contemporary stem design utilized a large patient database of high-resolution CT bone scans in order to determine the appropriate femoral head centers and neck lengths to assist in the recreation of natural head offset, designed to restore biomechanics. There are limited studies evaluating how radiographic software utilizing reference template bone can reconstruct patient composition in a model. The purpose of this study was to examine whether the application of a modern analytics system utilizing 3D modeling technology in the development of a primary stem was successful in restoring patient biomechanics, specifically with regards to femoral offset (FO) and leg length discrepancy (LLD). METHODS. Two hundred fifty six patients in a non-randomized, post-market multicenter study across 7 sites received a primary cementless fit and fill stem. Full anteroposterior pelvis and Lauenstein cross-table lateral x-rays were collected preoperatively and at 6-weeks postoperative. Radiographic parameters including contralateral and operative FO and LLD were measured. Preoperative and postoperative FO and LLD of the operative hip were compared to the normal, native hip. Clinical outcomes including the Harris Hip Score (HHS), Lower Extremity Activity Scale (LEAS), Short Form 12 (SF12), and EuroQol 5D Score (EQ-5D) were collected preoperatively, 6 weeks postoperatively, and at 1 year. RESULTS. The mean age is 62 years old (range 32 – 75), 136 male and 120 female, BMI 29.7. The preoperative FO and LLD of the operative hip were 43.5 mm (±9.0 mm) and 3.0 mm (±6.5 mm) compared to the native contralateral hip, respectively. The postoperative FO and LLD were 46.4 mm (±8.7 mm) and 1.6 mm (±7.6 mm) compared to the native contralateral hip, respectively. The change in FO on the operative side was 3.0 mm (±7.2 mm) (p<0.0001) and the change in LLD from preoperative to 6-weeks postoperative was 1.6 mm (±8.4 mm) (p=0.0052) (Figure 1), demonstrating the ability of this stem design to recreate normal
There are a growing number of younger patients with developmental dysplasia of hip, proximal femoral deformity and osteonecrosis seeking surgical intervention to restore quality of life, and the advent of ISTCs has resulted in a greater proportion of such cases being referred to existing NHS departments. Bone-saving hip athroplasty is often advocated for younger active patients, as they are potential candidates for subsequent revision arthroplasty. If resurfacing is contraindicated, short bone-conserving stems may be an option. The rationale for short stems in cementless total hip arthroplasty is proximal load transfer and absence of distal fixation, resulting in preserved femoral bone stock and avoidance of thigh pain. We have carried out 17 short stem hip replacements (Mini-hip, Corin Medical, Cirencester, UK) using ceramic bearings in 16 patients since June 2010. There were 14 females and 2 males, with a mean age of 50.1 years (range 35–63 years) at the time of the surgery. The etiology was osteoarthritis in 11, developmental dysplasia in 4, and osteonecrosis of the femoral head in one patient. All operations were performed through a conservative anterolateral (Bauer) approach. These patients are being followed and evaluated clinically with the Harris and Oxford hip scores, with follow-up at 6 weeks, 3 months, and annually thereafter. Initital results have been encouraging in terms of pain relief, restoration of leg length (one of the objectives in cases of shortening) and rage of movement. Radiological assessment has shown restoration of
The anterior approach is now an accepted approach for total hip arthroplasty. First described over a century ago, its popularity has grown significantly in the last decade with the advent of a reproducible technique on an orthopaedic table. Potential advantages include quicker recovery times, less post-operative pain, improved
Introduction: The goal is to avoid letting femoral deformity force suboptimal implant position/fixation. Suboptimal implant position has an adverse effect on