Advertisement for orthosearch.org.uk
Results 1 - 20 of 108
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 5 - 5
23 Jan 2024
Awad F Khan F McIntyre J Hathaway L Guro R Kotwal R Chandratreya A
Full Access

Introduction. Anterior cruciate ligament (ACL) injuries represent a significant burden of disease to the orthopaedic surgeon and often necessitate surgical reconstruction in the presence of instability. The hamstring graft has traditionally been used to reconstruct the ACL but the quadriceps tendon (QT) graft has gained popularity due to its relatively low donor site morbidity. Methods. This is a single centre comparative retrospective analysis of prospectively collected data of patients who had an ACL reconstruction (either with single tendon quadrupled hamstring graft or soft tissue quadriceps tendon graft). All surgeries were performed by a single surgeon using the All-inside technique. For this study, there were 20 patients in each group. All patients received the same post-operative rehabilitation protocol and were added to the National Ligament Registry to monitor their patient related outcome scores (PROM). Results. The average age of patients in the QT group was 29 years (16 males, 4 females) and in the hamstring group was 28 years (18 males, 2 females). The most common mechanism of injury in both groups was a contact twisting injury. There were no statistical differences between the two patient groups in regards to PROMS and need for further revision surgery as analysed on the National Ligament Registry. Conclusions. The all soft tissue QT graft seems to be equivocal to quadrupled hamstring graft in terms of patient function and recovery graft characteristics. Further research may be needed to elucidate the long-term results of the all soft tissue QT graft given its recent increase in use


Abstract. Objectives. To determine the effectiveness of LIA compared to ACB in providing pain relief and reducing opiates usage in hamstring graft ACL reconstructions. Materials and Methods. In a consecutive series of hamstring graft ACL reconstructions, patients received three different regional and/or anaesthetic techniques for pain relief. Three groups were studied: group 1: general anaesthetic (GA)+ ACB (n=38); group 2: GA + ACB + LIA (n=31) and group 3: GA+LIA (n=36). ACB was given under ultrasound guidance. LIA involved infiltration at skin incision site, capsule, periosteum and in the hamstring harvest tunnel. Analgesic medications were similar between the three groups as per standard multimodal analgesia (MMA). Patients were similar in demographics distribution and surgical technique. The postoperative pain and total morphine requirements were evaluated and recorded. The postoperative pain was assessed using the visual analogue scores (VAS) at 0hrs, 2hrs, 4hrs, weight bearing (WB) and discharge (DC). Results. There was no statistically significant difference in opiates intake amongst the three groups. When comparing VAS scores; there were no statistical difference between the groups at any of the time intervals that VAS was measured. However, the GA+LIA group hospital's LOS (m=2.31hrs, SD=0.75) was almost half that of GA+ACB group (m=4.24hrs, SD=1.08); (conditions t(72)=8.88; p=0.000). There was no statistical significance in the incidence of adverse effects amongst the groups. Conclusion. The LIA technique provided equally good pain relief following hamstring graft ACL reconstructions when compared to ACB, while allowing for earlier rehabilitation, mobilisation and discharge


Abstract. Objectives. To determine the effectiveness of LIA compared to ACB in providing pain relief and reducing opiates usage in hamstring graft ACL reconstructions. Materials and Methods. In a consecutive series of hamstring graft ACL reconstructions, patients received three different regional and/or anaesthetic techniques for pain relief. Three groups were studied: group 1: general anaesthetic (GA)+ ACB (n=38); group 2: GA + ACB + LIA (n=31) and group 3: GA+LIA (n=36). ACB was given under ultrasound guidance. LIA involved infiltration at skin incision site, capsule, periosteum and in the hamstring harvest tunnel. Analgesic medications were similar between the three groups as per standard multimodal analgesia (MMA). Patients were similar in demographics distribution and surgical technique. The postoperative pain and total morphine requirements were evaluated and recorded. The postoperative pain was assessed using the visual analogue scores (VAS) at 0hrs, 2hrs, 4hrs, weight bearing (WB) and discharge (DC). Results. There was no statistically significant difference in opiates intake amongst the three groups. When comparing VAS scores; there were no statistical difference between the groups at any of the time intervals that VAS was measured. However, the GA+LIA group hospital's LOS (m=2.31hrs, SD=0.75) was almost half that of GA+ACB group (m=4.24hrs, SD=1.08); (conditions t(72)=8.88; p=0.000). There was no statistical significance in the incidence of adverse effects amongst the groups. Conclusion. The LIA technique provided equally good pain relief following hamstring graft ACL reconstructions when compared to ACB, while allowing for earlier rehabilitation, mobilisation and discharge


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 44 - 44
1 Nov 2021
Salhab M Sonalwalkar S Anand S
Full Access

Introduction and Objective. Objectives: To determine the effectiveness of LIA compared to ACB in providing pain relief and reducing opiates usage in hamstring graft ACL reconstructions. Materials and Methods. In a consecutive series of hamstring graft ACL reconstructions, patients received three different regional and/or anaesthetic techniques for pain relief. Three groups were studied: group 1: general anaesthetic (GA)+ ACB (n=38); group 2: GA + ACB + LIA (n=31) and group 3: GA+LIA (n=36). ACB was given under ultrasound guidance. LIA involved infiltration at skin incision site, capsule, periosteum and in the hamstring harvest tunnel. Analgesic medications were similar between the three groups as per standard multimodal analgesia (MMA). Patients were similar in demographics distribution and surgical technique. The postoperative pain and total morphine requirements were evaluated and recorded. The postoperative pain was assessed using the visual analogue scores (VAS) at 0hrs, 2hrs, 4hrs, weight bearing (WB) and discharge (DC). Results. There was no statistically significant difference in opiates intake amongst the three groups. When comparing VAS scores; there were no statistical difference between the groups at any of the time intervals that VAS was measured. However, the GA+LIA group hospital's LOS (m=2.31hrs, SD=0.75) was almost half that of GA+ACB group (m=4.24hrs, SD=1.08); (conditions t(72)=8.88; p=0.000). There was no statistical significance in the incidence of adverse effects amongst the groups. Conclusions. The LIA technique provided equally good pain relief following hamstring graft ACL reconstructions when compared to ACB, while allowing for earlier rehabilitation, mobilisation and discharge


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 85 - 85
1 Mar 2009
Marx A Siebold R Ellermann A
Full Access

Introduction: Looking at the controversial discussion about indication, transplant choice and fixation techniques in active ACL-injured patients with open physes we recommend even in childhood an ACL reconstruction using a quadruple hamstring graft. Material and Methods: ACL-replacement was performed with a four strand hamstring graft using an Endobutton and a suture washer or staple for extracortical fixation. The drilled tunnels were positioned transepiphyseal in the anatomic position. A standardized examination was performed. IKDC, Tegner, Lysholm and Cincinatti Knee Score were raised. With the KT-1000 the functional stability was tested. Variation in leg length and leg deformity were analyzed. Results: 54 patients (22 female/32 male) operated at an age between 8 to 16 years (mean 13.3) were examined at mean f/u of 32 months (range 12–90) postoperatively. Measured with the Cincinatti and Lysholm Score 94% were classified as normal or nearly normal. Mean Tegner Score difference before trauma and postoperatively was 0.29 (range 0–3). Four patients developed instability due to an adequate trauma. Clinical and radiological examinations did not show growth disturbances in any patient. The results did not correlate to gender. Conclusion: Presuming a bad progression in conservatively treated ACL-injured young patients and performing a careful operative treatment (small tunnel diameters, ligamentous graft, extracortical fixation, etc.) the above mentioned technique shows satisfying results and should be considered as a standard treatment in this special group


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 103 - 103
1 Sep 2012
Leiter JR Elkurbo M McRae S MacDonald PB
Full Access

Purpose. The majority (73%) of orthopaedic surgeons in Canada prefer using semitendinosus-gracilis (STG) autograft for ACL reconstruction. However, there is large variation in tendon size between individuals which makes pre-operative estimation of graft size unpredictable. Inadequate graft size may require an alternative source of graft tissue that should be planned prior to surgery. The purpose of this study is to determine if clinical anthropometric data and MRI measurements of STG tendons can be used to predict hamstring graft size. Method. One-hundred and fourteen patients with ACL deficiency awaiting reconstruction using hamstring autograft were retrospectively evaluated. The following information was obtained from patient charts: height, weight, body mass index (BMI), age, and gender. Cross-sectional area (CSA) of gracilis (G) and semitendinosus (ST) tendons were determined from pre-operative MRI scans using NIH ImageJ analysis software. Actual STG graft diameters were obtained from operative reports. Correlations between patient height, weight, BMI, age, gender, ST-CSA, G-CSA, STG-CSA and intraoperative graft size were calculated to determine the association between these variables. Multiple stepwise regression was performed to assess the predictive value of these variables to intraoperative graft diameter. In addition, three investigators with no radiological experience made independent measurements of the ST and G tendons to determine the inter-rater reliability (ICC) of MRI measurements. Results. All variables were independently correlated with intraoperative graft size (p<0.001). However, based on multiple stepwise regression analysis, only models including STG-CSA (r2=.212; p<.001); STG-CSA and sex (r2=.285; p<.001); and STG-CSA, sex and weight (r2=.294; p<.001) were found to be significant predictors of graft size (when co-variation in other factors was controlled). Inter-class correlation coefficients demonstrated very high agreement between raters for measurements of the ST, G and STG (.816, .827, .863, respectively). Conclusion. Measurement of tendon CSA from MRI images is very reliable. A model including STG-CSA, sex and weight was found to be strongly predictive of hamstring graft diameter for ACL reconstruction. This model may enhance our ability to predict adequate graft size and identify instances that other graft tissues may be a better option. The results of this study may improve pre-operative planning for ACL reconstruction


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 446 - 447
1 Apr 2004
Bajwa A Lakhdawala A Finn P Lennox C
Full Access

Aims: Whether the harvesting of Hamstring graft for ACL reconstruction results in compromised knee flexion strength and proprioception, and hence knee function?. Methods: A prospective study, approved by the local Ethics committee, was undertaken to assess the function and strength of the knee joint in patients who had ACL reconstruction performed using a four-strand Hamstring graft. The contra lateral knee acted as control. 28 knee joints were studied with mean follow up 70.1 weeks (range 52–156). All operated knees received an extensive set regime of pre and post-operative physiotherapy. Assessment tools were Biodex dynamometry and stabilometery for hamstring and quadriceps strength and proprioception, clinical examination, Laxometer arthrometry for measured anterior draw. The knee function was assessed using a questionnaire incorporating International knee documentation committee (IKDC) proforma, Lysholm 2 score and Tegner’s activity scale. Results: Objective assessment using Biodex dynamometer pre-operatively showed that mean peak flexion torque was 67.86 N-m (SD± 24) in the involved knee and 76.1 N-m (SD± 22.2) in the healthy knee. Following reconstruction (mean 70.1 weeks post-op), mean peak flexion torque around the knee joint was 69.8 N-m (SD± 20.6) and 76.2 N-m (SD ±22.1) in the operated and non-operated knee (control) respectively. Flexion torque in the operated knee was as good as the control and not significantly different from the pre-operative levels. Mean Flexion: Extension ratio around the knee joint was 53.9% in the operated and 53.2% in non-operated sides. Mean stability index, measured using open eye stabilometery, was 3.5 (SD±2.4) on the operated and 3.1 (SD±1.8) on the non-operated side, with no significant difference demonstrable. The mean age of patients was 28.3 (range 18–44) years. Mean IKDC score following reconstruction was 74.8 (range 49–100), SD±18.5. There was significant improvement in pre and post reconstruction mean Lysholm 2 and Tegner’s activity scores (p< 0.01). Subjective function of the knee on a scale of 0–10 improved from pre-operative 3.1 to post-operative 7.7 (p< 0.01). Arthrometry at 25-degree flexion and 130 N force using Laxometer showed mean anterior laxity 5.3mm on the operated side and 3.1 on the healthy side (side to side difference 2.2mm). Conclusion: The function of the knee improved significantly following ACL reconstruction both objectively and subjectively. The harvesting of Hamstring as a graft neither compromises the flexion torque nor the proprioception around the knee joint


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 410 - 410
1 Sep 2012
Johnston A Stokes M Corry I Nicholas R
Full Access

Background. Anterior Cruciate Ligament Reconstruction is a commonly performed orthopaedic operation. The use of a four-strand semitendinosus and gracilis hamstring graft (STG) is a well established method of reconstruction to restore knee stability. Aim. To assess the ten year subjective knee function and activity level following STG anterior cruciate ligament reconstruction. Methods. 86 patients underwent anterior cruciate reconstruction by two knee surgeons in the year 1999. 80 patients meet the inclusion criteria of STG reconstruction by a standard operative technique. Patient evaluation was by completion of a Lysholm Knee Score and Tegner Activity Level Scale at a minimum of ten years from reconstructive surgery. This was by initial postal questionnaire and subsequent telephone follow-up. Results. 80 patients underwent anterior cruciate reconstruction with average age 30.9 years +/− 8.8 (15 to 58 years). There was a 77.5% (62 patients) response at ten years to the questionnaire. The mean Lysholm Knee Score at ten years was 78.4 +/− 12.8 (39 to 90). The mean activity level had decreased from 8.3 to 5.3 at ten years according to the Tegner Activity Scale. 11 patients required medial and lateral partial menisectomies at the time of original reconstruction. This group of patients had a Lysholm Knee Score of 67.6 +/− 19.1 and Tegner Activity Scale of 3.9 at ten years following reconstruction. 17 of the 80 patients (21.25%) required re-operation because of further knee symptoms, with 4 patients requiring revision of the anterior cruciate following re-rupture. Conclusion. Anterior Cruciate Ligament Reconstruction with four-strand STG hamstring graft provides a reliable method of restoring knee function with a 5% revision rate for re-rupture at ten years. Combined partial medial and lateral menisectomy at the time of the initial reconstruction is a poor prognostic indicator for function at ten years


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 189 - 189
1 Mar 2010
Barenius B Webster K Feller J
Full Access

It has been suggested that excessive tibial rotation during pivoting tasks is not controlled by single bundle ACL reconstruction (ACLR). This may be partly explained by graft orientation in the coronal plane. The purpose of this study was to assess tibial rotation after ACLR with an obliquely placed hamstring graft. 18 patients were evaluated. All patients had undergone a primary ACLR for an isolated ACL injury within 6 months of injury. All had a 4 strand graft, either semi-tendinosus alone (ST) or semitendinosus and gracilis (STGR) – 9 in each group, each with 2 females and 7 males. Follow-up was at least 2 years postoperatively and all patients had made a good functional recovery and returned to their pre-injury sporting activities. Evaluation consisted of IKDC 2000, instrumented laxity testing, and 3D motion analysis to record tibial rotation when subjects descended stairs and pivoted 90 degrees on landing using a similar protocol to one which has previously been reported. All patients had made an excellent recovery (mean IKDC score 100 for both groups) and there were no significant differences between the ST and STGR subjects for any of the background variables including anterior knee laxity. There were no differences in the maximal tibial rotational angle between the operated (mean: 20°, range: 10°– 27°) and non operated limb (mean: 21°, range: 6°– 42°). There was no significant difference between the graft types (ST: 20°, STGR: 21°). Females had greater tibial rotation on both the operated and non-operated sides compared to males. Contrary to previous reports, we found restoration of normal tibial rotation during the pivoting task after a single bundle ACLR. The lack of difference between the ST and STGR groups suggests that this restoration of normal tibial rotation is due to static rather than dynamic restraints. We suggest that it probably reflects the more horizontal graft orientation in the coronal plane for patients in the current study compared to that reported in previous studies


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 13 - 13
1 Jul 2012
Johnston AJ Stokes MJ Corry IS Nicholas RM
Full Access

Aim. To assess the ten year subjective knee function and activity level following four-strand semitendinosis and gracilis (STG) anterior cruciate ligament reconstruction. Methods. 86 patients underwent anterior cruciate reconstruction by two knee surgeons in the year 1999. 80 patients meet the inclusion criteria of STG reconstruction by a standard operative technique. Patient evaluation was by completion of a Lysholm Knee Score and Tegner Activity Level Scale at a minimum of ten years from reconstructive surgery. This was by initial postal questionnaire and subsequent telephone follow-up. Results. 80 patients underwent anterior cruciate reconstruction with average age 30.9 years +/− 8.8 (15 to 58 years). There was a 77.5% (62 patients) response at ten years to the questionnaire. The mean Lysholm Knee Score at ten years was 78.4 +/− 12.8 (39 to 90). The mean activity level had decreased from 8.3 to 5.3 at ten years according to the Tegner Activity Scale. 11 patients required medial and lateral partial menisectomies at the time of original reconstruction. This group of patients had a Lysholm Knee Score of 67.6 +/− 19.1 and Tegner Activity Scale of 3.9 at ten years following reconstruction. 17 of the 80 patients (21.25%) required re-operation because of further knee symptoms, with 4 patients requiring revision of the anterior cruciate following re-rupture. Conclusion. Anterior Cruciate Ligament Reconstruction with four-strand STG hamstring graft provides a reliable method of restoring knee function with a 5% revision rate for re-rupture at ten years. Combined partial medial and lateral menisectomy at the time of the initial reconstruction is a poor prognostic indicator for function at ten years


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 447 - 447
1 Apr 2004
Thomas N Pandit H Kankate R Venkatesh R Wandless F
Full Access

Introduction: The aim of this study was to compare two methods of femoral fixation for four strand Hamstring (4SH) primary ACL reconstruction: namely a recently introduced suspensory fixation using absorbable polylactic acid cross pins versus our traditional method of anchor fixation. Method: Forty-five consecutive patients, who had undergone primary ACL reconstruction using 4SH graft and the suspensory femoral fixation were prospectively evaluated by an independent observer. IKDC scores were recorded and laxity was assessed using cruciometer. These results were compared with a similar well-matched cohort of patients whose femoral fixation was with an anchor. Tibial fixation in both the groups was similar. Results: No significant difference was noted between the two groups on comparison of IKDC scores or cruciometer readings at a minimum one-year follow-up. Conclusions: This suspensory method of femoral fixation for a four-strand hamstring graft provided a secure fixation with satisfactory early clinical results. As this method of fixation is a new technique, further follow-up is needed for long-term validation


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 174 - 174
1 May 2011
Wipfler B Donner S Zechmann C Springer J Siebold R Paessler H
Full Access

The goal of this prospective, randomized study is the long-term evaluation of clinical, functional and MRI results after implant free press-fit ACL reconstruction performed using the bone-patella-tendon (PT) vs. hamstrings (HT) graft. 62 ACL insufficient patients without any concomitant sports injuries took part in a prospective, randomized study (31 PT, 31 HT). All procedures were conducted by the senior author between 10/98 and 09/99. Both surgical procedures were performed without any implants in press-fit technique with intra-operative x-ray control. At a mean FU time of 8.8 years 53 patients (28 PT, 25 HT) were examined by different scores, KT-1000, one leg hop test, kneeling- and knee-walking-test and isokinetic examination. We also performed bilateral MRI to determine the cartilage defects of both injured and uninjured knee. The results were compared with the intra-operative cartilage status. All MRIs were examined by an independent radiologist. For statistical analysis, the Student’s t-test and the chi. 2. –test was used (p< 0.05). On FU, neither the Tegner nor the Lysholm Score showed any significant results (Tegner 4.86 PT/5.29 HT, Lysholm 87.2/92.47). In the IKDC Score 84% of the PT and 94.4% of the HT group had a normal or nearly normal result (A or B) (p< 0.05), none had a severely abnormal result (D). The KT-1000 stability test and the pivot shift test showed no significance (KT-1000 side-to-side difference of < 3 mm 95.1%/91.7%; pivot glide in 28.0%/17.6%, no cross pivot shift). Isokinetic testing showed nearly normal quadriceps function in both groups (96.0%/96.4%), the hamstring strength was lower in the HT group without reaching statistical significance (100.3%/95.1%). The significant difference of the kneeling- and knee-walking-tests at 1 year FU persisted at year 9 (kneeling: 1.5/1.1; knee-walking: 1.72/1.14 (p< 0.05). Also, the single leg hop test was better in the HT group; however, the results were not significant (95.8%/99.1%). The MRI results showed no difference in cartilage status grade 0–2 using the ICRS-protocol (69.6%/65.0%), the cartilage status of the uninjured knees showed in both groups a similar distribution. Tunnel measurements did not show any widening of the femoral tunnel (−11.3%PT, −0.4%HT). However, the tibial tunnels were clearly widened in both groups (+16.0%/+15.7%). Also, the Caton Index for patellar height (−0.073/−0.085) as well as the sagittal ACL angle (+1.96°/+2.37°), both compared to the uninjured knee, revealed no significant difference. The implant free press-fit technique of ACL reconstruction using PT and HT grafts with anatomic graft placement is an excellent technique to preserve the cartilage and meniscal status without any significant differences between the operated and non-operated knees on FU. A significantly lower morbidity was noted in the HT group


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 147 - 148
1 Apr 2005
Haddo O Arun R Chauhan C
Full Access

Aim: To describe a new cosmetic and simple approach to harvest hamstring tendons in arthroscopic ACL reconstruction which reduces anterior knee sensitivity and patient morbidity.

Methods: Pre-operatively, the path of the hamstring tendons is identified and marked by asking the patient to flex their knee against resistance.

The thigh is placed over a bolster and the leg is allowed to hang over the end of the table.

The hamstring tendons are harvested through the pre-determined 2 centimetres horizontal incision on the posterior medial aspect of the thigh. The hamstring tendons which are individually identifiable at this point are isolated using a tendon hook. The fascial expansions of the tendons, which are easily accessible by this approach, are divided using dissecting scissors. A tendon stripper is then used to free the tendon from its muscular origin proximally and from its insertion at the pes anserinus distally.

Only a 5mm stab incision anteromedially is now required to make the tibial tunnel. The rest of the procedure is performed as described by EM Wolfe (1). The posteromedial incision is closed with subcuticular stitches. All other wounds are closed with steristrips including the 5mm anteromedial stab incision.

Conclusion: This new approach has a short learning curve with the harvesting time falling from 22 minutes to 9 minutes within the first 4 procedures, making it a good technique for the trainee surgeon. This approach provides an alternative to the traditional approach by being cosmetically pleasant, reducing anterior knee sensitivity and thereby improving the outcome.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 51 - 51
1 Mar 2021
Larose G McRae S Beaudoin A McCormack R MacDonald P
Full Access

There is increasing evidence that patients with ACL reconstruction using ipsilateral graft harvest are at greater risk of rupture (12.5%) on their contralateral compared to their surgical side (7.9%). The purpose of this study is to re-evaluate patients from a previous study comparing ipsi- versus contralateral graft harvest to compare ACL rupture rate at a minimum 10 year follow-up.

An attempt to contact all participants from a previously published study was made to invite them to return for a follow-up. The assessment included an International Knee Documentation Committee Knee Clinical Assessment (IKDC), isokinetic concentric knee flexion and extension strength testing, as well as the ACL-Quality of life (ACL-QOL). A chart review was conducted to identify or confirm subsequent ipsi- or contralateral knee surgeries.

In patients with ipsilateral graft, 3/34 (8.8%) re-ruptured and 3/34 (8.8%) had contralateral rupture. In the contralateral group, 1/28 (3.6%) re-ruptured and 2/28 (7.1%) had contralateral rupture. The relative risk (RR) of re-rupture with ipsilateral graft was 2.47 compared to using the contralateral site (p=0.42). RR of rupture on the contralateral side when ipsilateral graft was used was 1.23 compared to the alternate approach. Current contact information was unavailable for 21 patients. Of the 47 remaining, 37 were consented (79%). No difference in the ACL-QOL between groups (ipsilateral 68.4±24.4, contralateral 80.1±16.0, p=0.17) was observed. There were no differences in knee flexion strength between groups (peak torque flexion affected leg: ipsilateral 77.8nm/kg±27.4, contralateral: 90.0 nm/kg±35.1; p=0.32; Unaffected leg: ipsilateral: 83.3 nm/kg±30.2 contralateral 81.7 nm/kg±24.4; p= 0.89).

This study suggests that using the contralateral hamstring in ACL rupture is not associated with an increase in ACL rupture on either side. The risk of ACL injury was low in all limbs; therefore, a larger study would be required to definitively state that graft side had no impact.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 579 - 579
1 Nov 2011
MacDonald PB McCormack R McRae S Leiter J Zomar M Old J Wiens S
Full Access

Purpose: The hypothesis of this randomized controlled trial is patients undergoing ACL reconstruction using contralateral hamstring harvest will have better quality of life and strength than using ipsilateral graft.

Method: One hundred participants were assigned to the ipsilateral (IG) or contralateral (CG) group. Primary and secondary outcomes were ACL Quality of Life (ACL-QOL) and concentric isovelocity knee flexion/extension strength measured on a dynamometer at five speeds. Data was gathered pre-surgery, and at 3, 6, 12, and 24 months post-surgery. Findings to 12 months are presented.

Results: ACL-QOL scores and knee flexion/extension strength were not significantly different between groups across time. Comparing side-to-side strength within each group, knee extension strength was consistently higher on the non-reconstructed side. In the IG, there were no side-to-side differences in knee flexion strength. In the CG, flexion on the reconstructed side was stronger than the grafted side early post surgery (3, 6 months) at 60 degrees/s, but this pattern was reversed at 90, 150, and 210 degrees/s. Post-hoc comparisons revealed hamstring/ quadriceps (H/Q) ratios were not different between limbs in the CG or for the uninvolved limb for the IG. However, at most time points and speeds, the H/Q ratio for the involved limb in the IG was higher than the uninvolved limb in the IG and either limb in the CG.

Conclusion: This study reveals that ipsilateral graft harvest may alter the H/Q ratio. It was also demonstrated that contralateral graft harvest may normalize this effect. This may have some bearing on function and re-injury risk that should be further investigated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 27 - 27
1 Jul 2012
Henderson L Johnston A Stokes M Corry I Nicholas R
Full Access

Anterior cruciate ligament (ACL) reconstruction is a commonly performed operation. A variety of graft options are used with the most popular being bone-patellar-tendon-bone and hamstring autograft. There has been an increase in the popularity of hamstring autograft over the past decade.

The aim of the study was to assess the ten year subjective knee function and activity level following four-strand semitendinosis and gracilis (STG) anterior cruciate ligament reconstruction.

86 patients underwent anterior cruciate reconstruction by two knee surgeons over a 12 month period (January 1999 to December 1999). 80 patients meet the inclusion criteria of arthroscopic ACL reconstruction. The same surgical technique was used by both surgeons involving four-strand STG autograft, single femoral and tibial tunnels and aperture graft fixation with the Round headed Cannulated Interference (RCI) screw. Patient evaluation was by completion of a Lysholm Knee Score and Tegner Activity Level Scale at a minimum of ten years from reconstructive surgery. This was by initial postal questionnaire and subsequent telephone follow-up.

80 patients underwent anterior cruciate reconstruction with average age 30.9 years (15 to 58 years). There was a 77.5% (62 patients) response at ten years to the questionnaire.

The median Lysholm Knee Score at ten years was 94 (52 to 100). The median activity level had decreased from 9 to 5 at ten years according to the Tegner Activity Scale. 73% of patients reported a good or excellent outcome on the Lysholm score. The group of patients was further divided into those that required meniscal surgery and those that did not. The patients that did not require meniscal surgery had a median Lysholm score of 94 and those that required meniscal surgery had a similar median Lysholm score of 92.5. However it was noted that 8 patients required medial and lateral partial menisectomies at the time of original reconstruction. This group of patients had a median Lysholm Knee Score of 83.5 and Tegner Activity Scale of 4 at ten years following reconstruction. 17 of the 62 patients (27.4%) required re-operation because of further knee symptoms, with 4 patients requiring revision of the anterior cruciate following re-rupture.

In conclusion anterior cruciate ligament reconstruction with four-strand STG hamstring autograft provides a reliable method of restoring knee function, with a 6% revision rate for re-rupture at ten years. Combined partial medial and lateral menisectomy at the time of the initial reconstruction is a poor prognostic indicator of function at ten years.


Bone & Joint Open
Vol. 2, Issue 1 | Pages 66 - 71
27 Jan 2020
Moriarty P Kayani B Wallace C Chang J Plastow R Haddad FS

Aims. Graft infection following anterior cruciate ligament reconstruction (ACLR) may lead to septic arthritis requiring multiple irrigation and debridement procedures, staged revision operations, and prolonged courses of antibiotics. To our knowledge, there are no previous studies reporting on how gentamicin pre-soaking of hamstring grafts influences infection rates following ACLR. We set out to examine this in our study accordingly. Methods. This retrospective study included 2,000 patients (1,156 males and 844 females) who underwent primary ACLR with hamstring autografts between 2007 to 2017. This included 1,063 patients who received pre-soaked saline hamstring grafts for ACLR followed by 937 patients who received pre-soaked gentamicin hamstring grafts for ACLR. All operative procedures were completed by a single surgeon using a standardized surgical technique. Medical notes were reviewed and data relating to the following outcomes recorded: postoperative infection, clinical progress, causative organisms, management received, and outcomes. Results. Superficial wound infection developed in 14 patients (1.31 %) receiving pre-saline soaked hamstring grafts compared to 13 patients (1.38 %) receiving pre-gentamicin soaked hamstring grafts, and this finding was not statistically significant (p = 0.692). All superficial wound infections were treated with oral antibiotics with no further complications. There were no recorded cases of septic arthritis in patients receiving pre-gentamicin soaked grafts compared to nine patients (0.85%) receiving pre-saline soaked grafts, which was statistically significant (p = 0.004). Conclusion. Pre-soaking hamstring autographs in gentamicin does not affect superficial infection rates but does reduce deep intra-articular infection rates compared to pre-soaking hamstring grafts in saline alone. These findings suggest that pre-soaking hamstring autografts in gentamicin provides an effective surgical technique for reducing intra-articular infection rates following ACLR. Cite this article: Bone Jt Open 2021;2(1):66–71


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 137 - 137
4 Apr 2023
Chen P Chen Z Landao E Leys T Wang T Zheng Q Ding Y Zheng M
Full Access

To address the current challenge of anterior cruciate ligament (ACL) reconstruction, this study is the first to fabricate a braided collagen rope (BCR) which mimics native hamstring for ACL reconstruction. The study aims to evaluate the biological and biomechanical properties of BCR both in vivo and vitro. Rabbit ACL reconstruction model using collagen rope and autograft (hamstring tendon) was conducted. The histological and biomechanical evaluations were conducted at 6-, 12-, 18, 26-week post-operation. In vitro study included cell morphology analysis, cell function evaluation and RNA sequencing of the tenocytes cultured on BCR. A cadaver study was also conducted to verify the feasibility of BCR for ACL reconstruction. BCR displays satisfactory mechanical strength similar to hamstring graft for ACL reconstruction in rabbit. Histological assessment showed BCR restore ACL morphology at 26 weeks similar to native ACL. The superior dynamic ligamentization in BCR over autograft group was evidenced by assessment of cell and collagen morphology and orientation. The in vitro study showed that the natural collagen fibres within BCR enables to signal the morphology adaptation and orientation of human tenocytes in bioreactor. BCR enables to enhance cell proliferation and tenogenic expression of tenocytes as compared to hydrolysed collagen. We performed an RNA-Sequencing (RNA-seq) experiment where RNA was extracted from tenocyte seeded with BCR. Analysis of enriched pathways of the up-regulated genes revealed that the most enriched pathways were the Hypoxia-inducible factor 1-alpha (HIF1A) regulated networks, implicating the possible mechanism BCR induced ACL regeneration. The subsequent cadaver study was conducted to proof the feasibility of BCR for ACL reconstruction. This study demonstrated the proof-of-concept of bio-textile braided collagen rope for ACL reconstruction, and the mechanism by which BCR induces natural collagen fibres that positively regulate morphology and function of tenocytes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 6 - 6
10 Feb 2023
Lawless A Ebert J Edwards P Aujla R Finsterwald M Dalgleish S Malik S Raymond R Giwnewer U Simpson A Grant M Leys T D'Alessandro P
Full Access

Hamstring grafts have been associated with reduced strength, donor site pain and muscle strains following Anterior Cruciate Ligament Reconstruction (ACLR). Traditional graft fixation methods required both semitendinosus and gracilis tendons to achieve a graft of sufficient length and diameter, but newer techniques allow for shorter, broad single tendon grafts. This study seeks to compare the outcomes between Single Tendon (ST) and Dual Tendon (DT) ACLR, given there is no prospective randomised controlled trial (RCT) in the literature comparing outcomes between these options. In this ongoing RCT: (ANZ Clinical Trials Registry ACTRN126200000927921) patients were recruited and randomised into either ST or DT groups. All anaesthetic and surgical techniques were uniform aside from graft technique and tibial fixation. 13 patients were excluded at surgery as their ST graft did not achieve a minimum 8mm diameter. 70 patients (34 ST, 36DT) have been assessed at 6 months, using PROMS including IKDC2000, Lysholm and Modified Cincinnati Knee, visual analog scale for pain frequency (VAS-F) and severity (VAS-S), dedicated donor site morbidity score, KT-1000 assessment, and isokinetic strength. Graft diameters were significantly lesser in the ST group compared to the DT group (8.44mm/9.11mm mean difference [MD],-0.67mm; P<0.001). There was a significant and moderate effect in lower donor site morbidity in the ST group compared to the DT group (effect size [ES], 0.649; P = .01). No differences between groups were observed for knee laxity in the ACLR limb (P=0.362) or any of the patient-reported outcome measures (P>0.05). Between-group differences were observed for hamstrings strength LSI favouring the ST group, though these were small-to-moderate and non-significant (ES, 0.351; P = .147). ST (versus DT) harvest results in significantly less donor site morbidity and this is the first prospective RCT to determine this. There were no differences between ST and DT hamstring ACLR were observed in PROMs, knee laxity and hamstring strength. Younger female patients tend to have inadequate single tendon size to produce a graft of sufficient diameter, and alternative techniques should be considered. Further endpoints include radiological analysis, longer term donor site morbidity, revision rates and return to sport and will continue to be presented in the future


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 26 - 26
1 Mar 2005
Vane A Jones DG McMahon S
Full Access

The aim of this surgery was to determine current practice amongst orthopaedic surgeons in New Zealand with regard to Anterior Cruciate Ligament Reconstruction. All current members of the NZOA were sent a questionnaire on the numbers and proportions of grafts performed, methods of fixation, operative technique and return to sport. One hundred and ten of 140 questionnaires were returned completed. Ninety two orthopaedic surgeons were performing ACL reconstructions. Eight per cent performed patellar tendon grafts in preference to hamstring grafts, whereas 16% preferred hamstring over patellar tendon grafts. Almost 2000 patellar tendon grafts at an average of just over 20 per surgeon are performed each year compared to just over 500 hamstring grafts at an average of just over 15 per surgeon. Metal interference screws were the most common fixation device in patellar tendon and hamstring grafts. Patellar tendon grafts are the most common grafts used for ACL reconstruction with 80 % of those surveyed preferring to use patellar tendon over hamstring grafts. Metal interference screws were the most common fixation device. There is reasonable consensus regarding return to activity and sport