Advertisement for orthosearch.org.uk
Results 1 - 20 of 142
Results per page:
Bone & Joint Research
Vol. 6, Issue 10 | Pages 584 - 589
1 Oct 2017
den Teuling J Pauwels B Janssen L Wyers C Janzing HMJ van den Bergh J Morrenhof JW

Objectives. The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma. Methods. A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on plain anteroposterior radiographs of the proximal humerus. Results. No significant differences were found between simple and complex fractures of the proximal humerus in the BMD of the hip, FN or LS (all p > 0.3) or in the CI (p = 0.14). Only the body mass index was significantly higher in patients with a complex fracture compared with those with a simple fracture (26.9 vs 25.2; p = 0.05). Conclusion. There was no difference in BMD of the hip, FN, LS or CI of the proximal humerus in simple compared with complex fractures of the proximal humerus after a low-energy trauma. Factors other than the BMD and CI, for example body mass index, may play a more important role in the complexity of this fracture. Cite this article: J.W.A.M. den Teuling, B.S. Pauwels, L. Janssen, C.E. Wyers, H. M. J. Janzing, J.P.W. van den Bergh, J. W. Morrenhof. The Influence of bone mineral density and cortical index on the complexity of fractures of the proximal humerus. Bone Joint Res 2017;6:584–589. DOI: 10.1302/2046-3758.610.BJR-2017-0080


Bone & Joint Research
Vol. 5, Issue 10 | Pages 470 - 480
1 Oct 2016
Sabharwal S Patel NK Griffiths D Athanasiou T Gupte CM Reilly P

Objectives. The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. Methods. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed. Results. Seven studies including 528 patients were included. The overall meta-analysis found that there was no difference in clinical outcomes. However, subgroup and sensitivity analyses found improved patient outcomes for more complex fractures managed surgically. Four-part fractures that underwent surgery had improved long-term health utility scores (mean difference, MD 95% CI 0.04 to 0.28; p = 0.007). They were also less likely to result in osteoarthritis, osteonecrosis and non/malunion (OR 7.38, 95% CI 1.97 to 27.60; p = 0.003). Another significant subgroup finding was that secondary surgery was more common for patients that underwent internal fixation compared with conservative management within the studies with predominantly three-part fractures (OR 0.15, 95% CI 0.04 to 0.63; p = 0.009). Conclusion. This meta-analysis has demonstrated that differences in the type of fracture and surgical treatment result in outcomes that are distinct from those generated from analysis of all types of fracture and surgical treatments grouped together. This has important implications for clinical decision making and should highlight the need for future trials to adopt more specific inclusion criteria. Cite this article: S. Sabharwal, N. K. Patel, D. Griffiths, T. Athanasiou, C. M. Gupte, P. Reilly. Trials based on specific fracture configuration and surgical procedures likely to be more relevant for decision making in the management of fractures of the proximal humerus: Findings of a meta-analysisBone Joint Res 2016;5:470–480. DOI: 10.1302/2046-3758.510.2000638


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 276 - 276
1 Jul 2008
BÉGUIN L ADAM P MORTIER J FESSY M
Full Access

Purpose of the study: The reversed total shoulder prosthesis is one of the treatments currently proposed for excentered glenoid osteoarthritic degeneration with massive rotator cuff tears. In light of the mediocre or at best highly variable results obtained with osteosynthesis or humeral arthroplasty for four-fragment fractures of the proximal humerus, indications for the reversed total shoulder prosthesis have been widened to include this category of traumatology patients. The purpose of this prospective study was to report outcome with the reversed prosthesis used for complex fracture of the proximal humerus in subjects aged over 70 years. Material and methods: Ten patients, mean age 76 years, underwent surgery performed by the same surgeon to insert a Delta (DePuy) reversed prosthesis for four-fragment complex displaced fracture of the proximal humerus. The deltopectoral approach was used for all patients. The rotator cuff status was assessed intraoperatively. Clinical (Constant score) and radiological assessment were noted at 24 months. Results: During the operation, only three of the ten shoulders presented a full thickness rotator cuff tear. One patients developed a complication requiring revision: early dislocation revised with a retaining polyethylene insert without recurrent dislocation. There were no cases of glenoid loosening at last follow-up. The weighted Constant score was 65/100. A pain-free shoulder was achieved in all ten patients. Anterior elevation was 130° on average, internal rotation reached hand to buttocks and active external rotation 20°. Discussion: In patients aged over 70 years presenting a complex four-fragment fracture of the proximal humerus, the reversed prosthesis enables improved function and restoration of satisfactory joint movement. Early postoperative recovery and the gain in pain relief are encouraging factors. There was however unsatisfactory restoration of active rotation. For the elderly subject, free of a massive rotator cuff tear, rapid recovery after insertion of an reversed prosthesis should be balanced against the possible preservation of active rotations with an anatomic prosthesis


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 30 - 30
1 Jan 2004
Duparc F Trojani C Boileau P Le Huec J Walch G
Full Access

Purpose: Collapse or necrosis of the head of the humerus after fracture of the proximal humerus can be an indication for shoulder arthroplasty. The poor results classically reported have led to a search for factors predictive of the anatomic and functional outcome after arthroplasty for fracture sequelae. Material and methods: Among the 221 Aequalis prostheses implanted for the treatment of sequelae after fracture of the proximal humerus, 137 (62%) developed post-traumatic avascular osteonecrosis of the humeral head with a deformed callus of the tuberosity. Head tilt was in a valgus position in 83 shoulders and in a varus position in 54. Mean age was 61.49 years. The initial fractures were subtuberosity fractures in 20% of the cases, three-fragment fractures in 32%, and cephalobituberosity fractures with four fragments in 48% of the cases.Twenty-five percent of the patients had undergone initial osteosynthesis. The rotator cuff was repaired in 4.5%, and two osteotomies of the less tuberosity and four osteotomies of the greater tuberosity were performed at implantation. Pre- and postoperative clinical and functional outcomes were assessed with the Constant score and a function index composed of eleven usual movements. Results: Mean follow-up was 44 months (24–104), with a mean 42° gain in anterior elevation and a 29° gain in external rotation. The gain in the Constant score was +32 points (mean score 61), and +43% with the weighted score. The four subscores (pain, motion, activity, force) improved two-fold. Analysis of the eleven usual movements demonstrated recovery in 88% of the patients. The subjective satisfaction index was 86%. The mean Constant score improved significantly more after total arthroplasty (67 points) than after humerus prosthesis (55 points). Complications (per- or postoperative mechanical problem, infection, neurological disorder) or the need for revision were unfavourable elements. Discussion: Deformation and deviation of the tuberosities, especially the greater tuberosity, often leads to osteotomy during the implantation procedure. In this series, osteotomies were exceptional and functional outcomes showed that deviated tuberosities could be preserved without having an unfavourable effect on functional prognosis. Much on the contrary, the absence of a tuberosity osteotomy simplified the operative procedure and produced much better functional outcome than observed in earlier studies. The rate of complication for secondary prosthetic implantation is not negligible (15%) and a simplified procedure without osteotomy is a useful criterion. Furthermore, rehabilitation may be started earlier after implantation when it is not retarded by osteotomy bone healing, found to be an unfavourable factor. Conclusion: Implantation of a shoulder prosthesis after collapse or necrosis of the head of the humerus after proximal fracture with varus or valgus impaction has provided good functional outcome without tuberosity osteotomy since the deformation of the tuberosity is generally well tolerated


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 29 - 29
1 Jan 2004
Léger O Trojani C Coste J Boileau P Le Huec J Walch G
Full Access

Purpose: Nonunion of the surgical neck of the humerus can occur after orthopaedic or poorly-adapted surgery after displaced subtuberosity or cephalotuberosity fracture. The purpose of this study was to report functional and radiographic outcome after treatment with shoulder prosthesis. Material and methods: Twenty-two patients who had a non-constrained shoulder prosthesis were included in this retrospective multicentric study. Mean age was 70 years and mean follow-up was 45 months (range 2 – 9 years). The initial fracture had two fragments in six patients and was a three-fragment fracture involving the head and the tubercle in thirteen and a four-fragment fracture in three. Orthopaedic treatment was given in ten cases and surgical osteosynthesis was used in twelve. Time from fracture to implant insertion was 20 months. The deltopectoral approach was used for 21 humeral implants and one total shoulder arthroplasty (glenohumeral degeneration). The tuberosities were fixed to the cemented humeral stem and a crown of bone grafts were placed around the nonunion of the surgical neck. All patients were reviewed after a minimum of two years and assessed with the Constant score and x-rays. Results: The absolute Constant score improved from 23 reoperatively to 39 postoperatively with an anterior elevation of 53° to 63°. Pain score (from 3 to 9, p = 0.001) and external rotation (from 13° to 28°, p = 0.01) were significantly improved. Forty-five percent of the patients were satisfied and 55% were dissatisfied. The type of initial treatment, type of initial fracture, and time before implantation of the prosthesis did no affect final outcome. The complication rate was 36% (eight patients), and led to five revision procedures. The radiographic work-up disclosed six cases of persistent nonunion of the greater tuberosity, two proximal migrations of the prosthesis, and one humeral loosening. Conclusion: Outcome of shoulder prosthesis for sequela after fracture of the proximal humerus with nonunion of the surgical neck is poor. No improvement in anterior elevation, force, or motion was achieved. Shoulder prosthesis for sequelae of fracture of the proximal humerus with nonunion of the surgical neck should be considered as a “limited-objective” indication only providing beneficial pain relief


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 295 - 295
1 Nov 2002
Oran A Pritsch (Perry) M
Full Access

Introduction: Fracture of the proximal humerus are challenging for diagnosis and treatment. The vast majority of these fracture associated with osteoporosis in elderly. Decision making for the treatment must include all arguments of fracture type, physical demands and rehabilitation cooperation of patients. This is particularly crucial in proximal humerus fracture. Results of surgery including hemiarthroplasty are difficult to predict and many times type of surgical treatment can be determined intra-operative or at least after closed manipulation attempt. Material and methods: Between September 1998 to September 2000, 68 patients underwent surgery for proximal humerus fracture. Patients who underwent hemiarthroplasty were not included in this study. Diagnosis of the fracture was based on Neer classification system and was aided by CT scan. Type of surgery was made finally after closed manipulation attempt under anesthesia. Patients were consented for closed manipulation, open reduction and internal fixation or hemiarthroplasty. Data was collected retrospectively from outpatients notes. 32 males and 36 females, age 40–88 (mean: 62), underwent closed manipulation and pinning (30), ORIF included pinning and PDS suture (32) and ORIF included PDS suture only (6). Fracture type distributed as follows: 2 parts surgical neck – 9, 2 parts GT – 6, 3 parts – 29, fracture dislocations – 6, 4 parts – 12, impacted valgus fracture 6. Four threaded pins were inserted retrograde and trimmed under the skin. Two antegrade pins were left out of the skin and banded to prevent migration to the axilla. Patients were immobilized in shoulder immobilizer for 6 weeks when pins were removed in outpatient clinic. Control X-ray was taken at 2, 4, 6, 12 weeks. If fracture was noted to be unstable, X-ray was taken every week up to 4 weeks. In case of any deterioration after 12 weeks X-ray was taken to detect signs of AVN. Rehabilitation program commenced after clinical union with passive and assisted active for 4 weeks followed by active mobilization. Follow-up ranged from 10–34 months (mean: 22) and range of motion with X-ray description were documented. Results: All fractures but one were united, fracture position was noted in 31 patients as normal in 46 (68%), head-shaft in extension in 8 (11.7%), varus head – 7 (10%), valgus head – 1 (1.4%), prominent GT – 4 (6%), prominent LT – 3 (4.4%), complete displacement – 2 (2.8%), dislocated – 1 (1.4%). Mean range of motion for all groups was: Elevation – 144 (60–180), External Rotation – 54.6 (−10–80), Internal Rotation – L1 (Throchanter – T8). Statistical analysis for fracture groups showed best results for impacted valgus and greater tuberosity fracture after open reduction and worst results were noted for 4 parts fractures and fracture dislocation. Although the study was not randomized there was no significant difference between the group of closed pinning and open surgery. Complications: Six patients had revision surgery during the early follow up due to fixation failure. In one case repinning was performed, in 2 cases closed pinning transformed to open surgery and suture of GT, in one case osteotomy and re-insertion of LT was needed, one case complete lost of fixation ended in hemiarthroplasty and one case of fracture dislocation failed to closed and open surgery and need bone block (Laterget) to prevent re-dislocation. AVN was noted in 5 cases – 2 partial and 3 complete (3% and 4.4%, respectively). Pin tract infection occurred in the 6 of prominent antegrade pins and resolved after early removal of these pins without the retrograde pins. G-H arthrosis was noted in one case after 2 years. Conclusions: Surgical treatment of proximal humerus fracture and attempt to preserve the humeral head is alternative to conservative treatment or hemiarthroplasty from the other hand. High surgical are demanded and fixation cannot be guaranteed due to minimal bone stock for fixation. Partial loss of fixation still leave better position and reasonable functional results. Further attention is needed to the lesser tuberosity which could be seen better under fluoroscopy under anesthesia


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 12 - 13
1 Mar 2009
Obert L Clappaz P Gallinet D Garbuio P
Full Access

Introduction: The three or four-part fracture of the proximal humerus remains a challenging fracture in the case of elderly patient. In this continuing prospective study we compared the outcome after implantation of a shoulder hemiprosthesis of the anatomical generation and a reversed prosthesis. Material and methods: 34 shoulder prosthesis were implanted in patients older than 70 between june 1996 and june 2004. All patients were evaluated by a surgeon not involved in treatment concerning activities of daily living (DASH scoring), clinical outcome (Constant-Murley Score), radiological results, and a summary of complications. Group 1: anatomical prosthesis (Tornier): At an average follow-up of 16,5 (range 6–55) months, 13/17 patients with an average age of 78,6 years (70–95), were evaluated. Group 2: reversed prosthesis (Depuy): At an average follow-up of 12,6 (range 6–18) months, 13/17 patients with an average age of 77,1 years (70–84), were evaluated. In this group functional treatment was started immediately after surgery. Results: concerning age, follow up and dash scoring there were no difference between two groups. In reversed group : the outcome was better (Constant-Murley: 79,5 (57,8–100) vs 57,1 (21–85) p=0.005), the average active elevation was better by 30° (p< 0.001) and the average active abduction was better by 53° (p< 0.001). 7/13 cases of glenoid notching stage 2 or 3 were noted. In anatomical group : the average active external rotation was better by 10° (p=0.01). Tubercle fixations failed in 6/13 cases. Discussion: No comparative study has still been published between the two sort of implant in elderly patients. Our results of shoulder arthroplasty in acute injury to the proximal humerus with reversed prosthesis are in agreement with the preliminary results reported by Sirveau. At short follow up, reversed prosthesis allow to reach early mobilisation with best functional results. Rotation remains the key point : with a significant gain in active abduction and elevation the reversed prosthesis group do not reach a better dash scoring. Attachment fixation of the posterior rotator cuff must probably be discussed in reversed prosthesis in acute fracture


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 4 - 4
1 Nov 2022
Adapa A Shetty S Kumar A Pai S
Full Access

Abstract. Background. Fractures Proximal humerus account for nearly 10 % of geriatric fractures. The treatment options varies. There is no consensus regarding the optimal treatment, with almost all modalities giving functionally poor outcomes. Hence literature recommends conservative management over surgical options. MULTILOC nail with its design seems to be a promising tool in treating these fractures. We hereby report our early experience in the treatment of 37 elderly patients. Objectives. To evaluate the radiological outcome with regards to union, collapse, screw back out/cut through, implant failures, Greater tuberosity migration. To evaluate the functional outcome at the end of 6 months using Constant score. Study Design & Methods. All patients aged >65 years who underwent surgery for 3,4-part fracture proximal humerus using the MULTILOC nail were included in the study after consent. Pre – existing rotator cuff disease were excluded. Within the time frame, a total of 39 patients underwent the said surgery. 2 patients were lost to follow up. All the measurements were taken at the end of 6 months and results tabulated and analysed. Results. Union was achieved in all the 37 patients. There were no varus collapse or screw backout/cut through seen in any of the patients. There was Greater tuberosity migration in 1 patient who underwent revision surgery at 6 weeks. All the patients got a minimum of 70 degrees of abduction and forward flexion. We had 29 excellent, 6 good, 2 fair and none poor results as per Constant scoring system. Study done in Tejasvini Hospital & SSIOT Mangaluru India


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 342 - 342
1 May 2010
Obert L Sverin R David G Nicolas B Pascal C Patrick G
Full Access

Introduction: The three or four-part fracture of the proximal humerus remains a challenging fracture in the case of elderly patient. In this continuing prospective study we compared the outcome after implantation of a shoulder hemiprosthesis of the anatomical generation and a reversed prosthesis. Material and Methods: 34 shoulder prosthesis were implanted in patients older than 70 between june 1996 and june 2004. All patients were evaluated by a surgeon not involved in treatment concerning activities of daily living (DASH scoring), clinical outcome (Constant-Murley Score), radiological results, and a summary of complications. Group 1: anatomical prosthesis (Tornier): At an average follow-up of 16,5 (range 6–55) months, 13/17 patients with an average age of 78,6 years (70–95), were evaluated. Group 2: reversed prosthesis (Depuy): At an average follow-up of 12,6 (range 6–18) months, 13/17 patients with an average age of 77,1 years (70–84), were evaluated. In this group functional treatment was started immediately after surgery. Results: concerning age, follow up and dash scoring there were no difference between two groups. In reversed group: the outcome was better (Constant-Murley: 79,5 (57,8–100) vs 57,1 (21–85) p=0.005), the average active elevation was better by 30° (p< 0.001) and the average active abduction was better by 53° (p< 0.001). 7/13 cases of glenoid notching stage 2 or 3 were noted. In anatomical group: the average active external rotation was better by 10° (p=0.01). Tubercle fixation’s failed in 6/13 cases. Discussion: No comparative study has still been published between the two sort of implant in elderly patients. Our results of shoulder arthroplasty in acute injury to the proximal humerus with reversed prosthesis are in agreement with the preliminary results reported by Sirveau. At short follow up, reversed prosthesis allow to reach early mobilisation with best functional results. Rotation remains the key point: with a significant gain in active abduction and elevation the reversed prosthesis group do not reach a better dash scoring. Attachment fixation of the posterior rotator cuff must probably be discussed in reversed prosthesis in acute fracture


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 383 - 392
1 Mar 2017
Handoll HH Keding A Corbacho B Brealey SD Hewitt C Rangan A

Aims. The PROximal Fracture of the Humerus Evaluation by Randomisation (PROFHER) randomised clinical trial compared the operative and non-operative treatment of adults with a displaced fracture of the proximal humerus involving the surgical neck. The aim of this study was to determine the long-term treatment effects beyond the two-year follow-up. Patients and Methods. Of the original 250 trial participants, 176 consented to extended follow-up and were sent postal questionnaires at three, four and five years after recruitment to the trial. The Oxford Shoulder Score (OSS; the primary outcome), EuroQol 5D-3L (EQ-5D-3L), and any recent shoulder operations and fracture data were collected. Statistical and economic analyses, consistent with those of the main trial were applied. Results. OSS data were available for 164, 155 and 149 participants at three, four and five years, respectively. There were no statistically or clinically significant differences between operative and non-operative treatment at each follow-up point. No participant had secondary shoulder surgery for a new complication. Analyses of EQ-5D-3L data showed no significant between-group differences in quality of life over time. Conclusion. These results confirm that the main findings of the PROFHER trial over two years are unchanged at five years. Cite this article: Bone Joint J 2017;99-B:383–92


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 120 - 120
1 Sep 2012
Burke N Kennedy J Fitzpatrick D Mullett H
Full Access

Purpose

Locking plates are widely used in clinical practice for the surgical treatment of complex proximal humerus fractures, especially in osteoporotic bone. The aim of this study is to assess the biomechanical influence of the infero-medial locking screws on maintaining reduction of the fragments in a proximal humerus fracture.

Materials & Methods

A standard 3-part proximal humerus fracture was created in fourth generation humerus saw bones. Each specimen was anatomically reduced and secured with a PHILOS locking plate. Eleven of the specimens had infero-medial locking screws inserted, and 11 specimens did not. Each humerus sawbone underwent cyclical loading at 532N, as previous studies showed this was the maximum force at the glenohumeral joint. The absolute inter-fragmentary motion was recorded using an infra-red motion analysis device. Each specimen was then loaded to failure.


Abstract. Reverse shoulder arthroplasty (RSA) is being increasingly used for complex, displaced fractures of the proximal humerus. The main goal of the current study was to evaluate the functional and radiographic results after primary RSA of three or four-part fractures of the proximal humerus in elderly patients. Between 2012 and 2020, 70 consecutive patients with a recent three- or four-part fracture of the proximal humerus were treated with an RSA. There were 41 women and 29 men, with a mean age of 76 years. The dominant arm was involved in 42 patients (60%). All surgeries were carried out within 21 days. Displaced three-part fracture sustained in 16 patients, 24 had fracture dislocation and 30 sustained a four-part fracture of the proximal humerus. Patients were followed up for a mean of 26 months. The mean postoperative OSS at the end of the follow-up period was 32.4. The mean DASH score was 44.3. Tuberosity non-union occurred in 18 patients (12.6%), malunion in 7 patients (4.9%), heterotopic ossification in 4 patients (2.8%) and scapular notching in one patient. Anatomical reconstruction was achieved in 25 patients (17.5%), the influence of greater tuberosity healing on shoulder function could not be demonstrated. Heterotopic ossification seems to affect OSS and QDASH, we found statistically significant relation between HO and clinical outcomes. Patients with heterotopic ossification had significantly lower postoperative scores on DASH and OSS (P = .0527). Despite expecting good functional outcome with low complication rate after RSA, the functional outcome was irrespective of healing of the tuberosities


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 89 - 89
1 Oct 2022
Alier A Gasol B Pérez-Prieto D Santana F Torrens C
Full Access

Aim. A significant number of patients undergoing shoulder arthroplasty surgery have C acnes contamination at the end of the primary surgery. The objective of this study is to determine whether patients with C acnes contamination at the end of their primary shoulder surgery have a worse prognosis than those who end up without C. acnes contamination. Method. Prospective study including all patients who underwent a reverse shoulder prosthesis from January 2015 to December 2018. In all of them, 5 to 12 cultures were performed during primary surgery. The patients underwent surgery for shoulder arthritis secondary to rotator cuff tears, acute fracture of the proximal humerus, and sequelae of fracture of the proximal humerus. Exclusion criteria included the existence of previous surgeries on the affected shoulder, the presence of signs of infection, having received infiltrations and / or complementary invasive examinations (Arthro-MRI and Arthro-CT). Follow-up from 2 to 5 years. Functional assessment according to the Constant Functional Scale. All complications were also recorded. Results. 162 patients were included. Of these, 25 had positive cultures for C. acnes at the end of primary shoulder surgery. Average age of 74.8 years. 136 women and 26 men. 75.9% Shoulder arthritis secondary to rotator cuff tears, 13.6% acute fractures and 10.5% sequelae of fractures. There were no differences between patients with C. acnes and those without C. acnes regarding age and indication for surgery. Predominance of men in the group with positive C. acnes (p <0.001). No differences at 2 and 5 years in the Constant functional scale between the two groups (2 years, 59.6 vs 59.2 p 0.870) (5 years, 62.4 vs 59.5 p 0.360). Significant differences regarding the number of complications (p 0.001). Patients without C. acnes had 1 aseptic loosening of the metaglene and patients with C. acnes had 2 infections, 1 dislocation, and 1 revision surgery. Patients with contamination by C. acnes had more comorbidities (p 0.035) than patients without contamination. Conclusions. Patients with C acnes contamination at the end of primary surgery do not have functional differences when compared with patients without contamination at 2 and 5 years, but they have a higher number of complications in the medium term


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 13 - 13
1 Dec 2023
Elgendy M Makki D White C ElShafey A
Full Access

Introduction. We aim to assess whether radiographic characteristics of the greater tuberosity fragment can predict rotator cuff tears inpatients with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity. Methods. A retrospective single-centre case series of 61 consecutive patients that presented with anterior shoulder dislocations combined with an isolated fracture of the greater tuberosity between January 2018 and July 2022. Inclusion criteria: patients with atraumatic anterior shoulder dislocation associated with an isolated fracture of the greater tuberosity with a minimum follow-up of 3-months. Exclusion criteria: patients with other fractures of the proximal humerus or glenoid. Rotator cuff tears were diagnosed using magnetic resonance or ultrasound imaging. Greater tuberosity fragment size and displacement was calculated on plain radiographs using validated methods. Results. The case series was composed of 22 men and 39 women with a mean age of 65 years (29 - 91 years). The mean follow-up was 15months and median follow up 8.5 months (3 – 60 months). A rotator cuff tear was diagnosed in 14 patients (16%) and involved the supraspinatus (13), infraspinatus (4) and subscapularis (2). Full-thickness tears occurred in 6 patients and partial-thickness tears in 8patients. The mean time from initial injury to rotator cuff tear diagnosis was 5 months (2 – 22 months). The mean greater tuberosity fragment length was 23.4 mm in rotator cuff tear patients versus 32.6 mm in those without a tear (p = 0.006, CI: -15 - -2). The mean greater tuberosity. fragment width was 11.1 mm in rotator cuff tear patients versus 17.8 mm in those without a tear (p = 0.0004, CI: -10 - -2). There was no significant difference in the super inferior and anteroposterior fragment displacement between the two groups. Conclusion. In patients with shoulder dislocations combined with an isolated fracture of the greater tuberosity, rotator cuff tears are associated with a smaller sized greater tuberosity fragment


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 117 - 117
1 Nov 2021
Longo UG
Full Access

The function of the upper extremity is highly dependent on correlated motion of the shoulder. The shoulder can be affected by several diseases. The most common are: rotator cuff tear (RCT), shoulder instability, shoulder osteoarthritis and fractures. Rotator cuff disease is a common disorder. It has a high prevalence rate, causing high direct and indirect costs. The appropriate treatment for RCT is debated. The American Academy Orthopaedic Surgeons guidelines state that surgical repair is an option for patients with chronic, symptomatic full-thickness RCT, but the quality of evidence is unconvincing. Thus, the AAOS recommendations are inconclusive. We are performing a randomized controlled trial to compare surgical and conservative treatment of RCT, in term of functional outcomes, rotator cuff integrity, muscle atrophy and fatty degeneration. Shoulder instability occurs when the head of the upper arm bone is forced out of the shoulder socket. Shoulder instabilities have been classified according to the etiology, the direction of instability, or on combinations thereof. The Thomas and Matsen classification, which is currently the most commonly utilized classification, divides shoulder instability events into the traumatic, unidirectional, Bankart lesion, and surgery (TUBS) and the atraumatic, multidirectional, bilateral, rehabilitation, and capsular shift (AMBRI) categories. The acquired instability overstress surgery (AIOS) category was then added. Surgical procedures for shoulder instability includes arthroscopic capsuloplasty, remplissage, bone block procedure or Latarjet procedure. Reverse total shoulder arthroplasty (RTSA) represents a good solution for the management of patients with osteoarthritis or fracture of the proximal humerus, with associated severe osteoporosis and RC dysfunction


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 294 - 295
1 Nov 2002
Volpin G
Full Access

Introduction: The treatment of fractures of the proximal humerus is still controversial. Conservative treatment may result in severe disability due to malunion and shoulder stiffness. Open reduction and rigid fixation requires extensive soft tissue exposure, which may result in a high incidence of avascular necrosis of the proximal humerus. Today, many authors are in the opinion that “minimal osteosynthesis” of such fractures is preferable to rigid fixation. It may be achieved by K.W. techniques, lag screws, rush pins, percutaneous pinning or percutaneous external fixation. This study reviews our experience with comminuted fractures of the proximal humerus treated by different minimal invasive techniques of fixation, using functional evaluation and radiological assessment. Materials and methods: This study consists of 76 patients with comminuted fractures of the proximal humerus (33 M, 44 F, 18–89 year old, mean 52/5Y) with follow-up of 2–6 years (mean 3.5Y). They were treated by minimal invasive surgical techniques: 53 of them by closed reduction and percutaneous pinning and the remaining 23 by ORIF and minimal osteosynthesis. All patients were evaluated by Neer’s shoulder grading score and radiographs. Results: Overall results were excellent and good in 85% of patients with 2, and 3 parts fractures of the proximal humerus, treated either by closed or open minimal osteosynthesis techniques, with some better results in less comminuted fractures. 9/13 (69%) of young patients with 4 part fractures treated by closed percutaneous minimal fixation had good functional results. In four other patients the clinical results were poor and two of them developed AVN of the humeral head. 5/8 (62.5%) of young patients with 4 part fractures treated by ORIF and minimal fixation had good functional results. In three other patients the clinical results were poor and one of them developed AVN of the humeral head. Conclusions: Based on this study it seems that “minimal osteosynthesis” by K.W. techniques and by lag screws, by closed or open reduction, remains as the first optional treatment of complex fractures of the shoulder, even in young patients with a 4 part fracture


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 141 - 141
1 Mar 2006
Volpin G Shtarker H Kaushanski A Shachar R
Full Access

Introduction: Management of displaced comminuted fractures of the proximal humerus in the elderly is still controversial. Conservative treatment may result in severe disability due to malunion and shoulder stiffness. Rigid fixation of these fractures by plates may offer stability in anatomic position, but requires in most cases extensive soft tissue exposure and may result in a relatively high incidence of avascular necrosis of the humeral head. Therefore, many authors are today of the opinion that hemiarthroplasty of the shoulder joint in such fractures is preferable to rigid fixation. This study reviews our experience with hemiartroplasty of the shouldere in elderly patients with comminuted fractures of the proximal humerus. Material & Methods: This study consists of 39 Pts. (27F, 12M; 72–89 year old, mean 76.5Y; 12 with 3 parts fractures and 27 with 4 parts fracture) treated by hemiarthroplasty of the proximal humerus. Patients were followed for 2–8 years (mean 4Y), and evaluated by the Neer‘s shoulder grading score and radiographs. Results: 74% of the patients treated by hemiarthroplasty had satisfactory results. They were almost free of pain, but most of them had only a moderate improvement in shoulder motion (active abduction or flexion of 110–130 degrees were observed in 4/39, of 90–110 degrees in 7/39, of 50–90 degrees in 17/39 and of 30–50 degrees in 11/29). Conclusions: Based on this study it seems that pain relief by hemiarthroplasty may be achieved in most older patients with comminuted fractures of the proximal humerus, but the gain in shoulder function is relatively limited


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 91 - 91
1 Mar 2008
Walsh S Reindl R Harvey E Berry G Beckman L Steffen T
Full Access

Many two-part fractures of the proximal humerus are treated conservatively due to the frequent failure of internal fixation. The current investigation examines the biomechanical properties of a unique plate versus a standard plate for internal fixation of proximal humerus fractures. The unique plate employs screws that thread into the plate, creating a multi-planer, fixed angle device. A cadaveric model was developed that relied on the rotator cuff musculature as the primary deforming force. The locking plate displayed significantly greater holding power on the humeral head (p=0.007). This may lead to more consistent results in two-part fractures treated with internal fixation. The current investigation evaluates a unique plate designed to treat fractures of the proximal humerus. The plate employs screws that thread into the plate creating a fixed angle device. This plate was tested versus a standard cloverleaf plate. The locking plate displayed greater holding power on the humeral head in the model tested. This may lead to decreased failure rates in two-part fractures treated with internal fixation. Many two-part fractures of the proximal humerus are treated conservatively due to the frequent failure of common internal fixation modalities. This is done with the acceptance of possible non-union and loss of function. A more reliable method for stable internal fixation is therefore desirable. A significant difference was found (p=0.007) with the locking plate displaying greater holding capability on the humeral head. Eight pairs of preserved, cadaveric humeri were dissected and plated with either the locking plate or standard cloverleaf plate followed by an osteotomy at the surgical neck. A servo-hydraulic testing machine was then used to pull on the rotator cuff musculature until failure was achieved. Failure of the plate-head interface was reached in five of the eight pairs. Previous biomechanical studies have not taken into account the clinical mode of failure when testing internal fixation modalities for proximal humerus fractures. The current study has reproduced failure into varus by relying on the rotator cuff musculature as the primary deforming force. Funding: All implants donated by Synthes, Canada


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 295 - 295
1 Nov 2002
Morag G Maman E Steinberg E Mozes G
Full Access

Introduction: Fractures of the proximal humerus account for 4–5% of all fractures. The number one cause of this type of fracture is age related osteoporosis associated with minimal trauma. Approximately 80% of these fractures are non or minimally-displaced, and can be treated conservatively with good results. However, treatment of displaced complex fractures is still controversial. The disadvantage of open procedures is the risk of damaging the blood supply to the humeral head, leading to a higher incidence of avascular necrosis. Closed Reduction and Percutaneous Fixation (CRPF) is a minimal invasive procedure with a lower risk of damaging the blood supply. The main complication of this technique is loosening of the guide wires and displacement of the fragments requiring a second operation. Purpose: The guide wire loosening leads us to improve the technique by adding an external fixator to stabilize the guide wires and secure fragment positioning. We report our experience of treating displaced fractures of the proximal humerus with Closed Reduction and External Fixation (CREF). Materials and methods: Between the years 1996–2001 we operated on 37 patients for 38 complex fractures and fracture dislocations of the proximal humerus. We had 16 two part fractures, 13 three part fractures, 3 four part fractures, 5 two part fracture dislocation and 1 four part fracture dislocation according to the Neer’s classification. The mean age was 60 years old ranging from 16–90 with a male to female ratio of 1:1. The patients were placed in a beach chair position using an image intensifier for AP and axillary views. Because the closed reduction was unsatisfactory, six patients underwent open reduction and external fixation. The remaining 32 shoulders underwent CREF. Passive motion exercises were initiated on the first postoperative day. The external fixator was removed after four to six weeks (mean time for external fixator – 5.3 weeks). After removing the external fixator the patients began with active assisted mobilization of the shoulder and isometric strengthening exercises. Results: The average follow up was 31.6 months (range 6–60 months). No loosening was observed upon removal of the external fixator, however the following complications were encountered: 5 patients had superficial pin tract infections, 1 patients developed an avascular necrosis of the humeral head, 1 patient had a non union of the fracture. Of the remaining patients, 13 patients had an excellent result, 15 patients had a good result and 5 patients had a fair result. Conclusions: CREF is a minimal invasive technique for complex fractures of the proximal humerus, greatly reducing the damage to the blood supply when compared to open surgical procedures. It offers a better stabilization than CRPF, thus reducing the complication rate. The percutaneous technique causes less scaring and therefore a shorter rehabilitation program. Consequently, this procedure is recommended for complex fractures of the proximal humerus


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 97 - 97
1 Sep 2012
Brorson S Frich LH Winther A Hrobjartsson A
Full Access

Introduction. There is considerable uncertainty about the optimal treatment of displaced four-part fractures of the proximal humerus. Within the last decade locking plate technology has been considered a breakthrough in the treatment of these complex injuries. Methods. We systematically identified and reviewed clinical studies of the benefits and harms after osteosynthesis with locking plates in displaced four-part fractures. Results. We included fourteen studies with 374 four-part fractures. There were no randomised trials, one prospective observational comparative study, three retrospective observational comparative studies, and ten case series. Small studies with a high risk of bias precluded reliable estimates of functional outcome. Unexpected high rates of complications (range 16% to 64%) and re-operations (range 11% to 27%) were reported. Conclusion. The empirical foundation for the clinical value of locking plates in displaced four-part fractures of the proximal humerus is very sketchy. We emphasise the need for well conducted randomised trials and observational studies